The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROV HOT WTR TO ALL FIXTURES | FIRST FLOOR & THROUGH-OUT | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | THROUGH-OUT | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | FIRST FLOOR CEILING | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | FIRST FLOOR BATH TUB WORN PROCLIAN PROBLEMS PERMIT REQUIRED FOR REPLACEMENT | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | 6418 S EBERHART AVE | COMPLAINT | FAILED | View | |
LICENSED BONDED PLMBG CONTRCTR | 6418 S EBERHART AVE | COMPLAINT | FAILED | View | |
REPAIR PORCH SYSTEM | REAR PORCH BUTT JOINED COLUMNS, LEDGERS NOT BOLTED, GUARD RAILS LOOE NOT 42" HIGH 8 INCH PEDISTALS UNDERSIZED , 2X6 JOINTS OVER SPANNED 6X6 BEAMS OVER 10' SWAYS AT PIER, 6X6 UNSUPPORTED (VISIT SUPERVISOR FOR EXPLANATION IF YOU NEED TO) | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF ROTTED AT REAR PORCH | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
PIGEONS-NESTING | PIGEONS ROOSTING 2ND FLOOR REAR PORCH | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR FRONT STAIRWELL CEILING | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | FRONT INTERIOR EXIT UNLIT | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | NO PEEPHOLES | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | TEMPORAY SUPPORT AT FRONT STAIRS, AT HANDRAIL POST BETWEEN BASEMENT TO 1ST | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BASEMENT APARTMENT WINDOWS BOARDED | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS NEEDED FOR REPAIRS PORCH GUIDE LINES AND DRAWING MAY BE AVAILABLE AT WWW CITY OF CHICAGO ORG AT NO CHARGE | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNER INFORMATION | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | GROUND APT. - NO RESPONSE;1ST. FL. APT. - ENTRY REFUSED;2ND. FL. APT. - NO RESPONSE;UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF SR#16-008242; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY /SMOKE DETECTOR - MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY [GRADE TO 2ND. FL.] /TREADS - LOOSE; RUBBER MAT [EVERY TREAD] - CURLED, BUCKLING UP, LOOSE - TRIP HAZARD;PERMIT REQUIRED; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | FRONT ELEVATION /INTERIOR [FOYER] FRAME - MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ELEVATION /EXTERIOR DOOR - OFF HINGES; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ELEVATION /EXTERIOR DOOR HARDWARE - CLOSER AND LOCK-SET - MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION /CHIMNEY - WASHED OUT MORTAR; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION /CHIMNEY CAPPING - MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT, REAR, SOUTH, NORTH ELEVATION /EXTERIOR WALL - MISSING BRICK, FRACTURED, WASHED OUT MORTAR;MASONRY PERMIT REQUIRED; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | SOUTH ELEVATION /PARAPET WALL - WASHED OUT MORTAR; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | REAR ELEVATION /1ST. FL. LANDING - EXPOSED WIRING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | SOUTH ELEVATION /AREAWAY CEILING - PLYWOOD; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | REAR AND SOUTH ELEVATION /STONE WINDOW SILLS - WASHED OUT MORTAR; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR ELEVATION /DOWNSPOUT - MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR FENCE/GATE - BROKEN, WITH MISSING SECTIONS; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD - 2 [TWO] ABANDONED VEHICLES; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD - JUNK, DEBRIS; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR YARD /SERVICE WALK - MISSING; GARAGE SLAB /CRACKED, UNEVEN, SPALLING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH WITH ROOF;COLUMNS /6X6 COLUMN [SUPPORTS 6X6 ROOF LOOK-OUTS] STACKED UP ON TOP OF LANDING, SCABBED, FASTENED WITH NAILS ONLY;LEDGER BEAMS /FASTENED TO BUILDING EXTERIOR WALLS WITH BOLTS OF ONLY ½ INCH DIA. AT 42 INCHES O.C.;BEAM POCKETS LEFT WITH VOIDS, WITH WOOD BLOCKS - MORTAR MISSING; STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, NOT ATTACHED TO BUILDING EXTERIOR WALL, SCABBED; STRINGERS WEAK; STRINGER [AT GRADE] ERECTED ON SOIL;STAIRS /TREADS - LOOSE;RAILINGS /GUARD RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PLANS AND PERMIT REQUIRED; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR ELEVATION /ROOF [OVER 2 STORY WOOD PORCH] - UNDERSIZED 2X6 ROOF JOISTS SPAN 8 FEET 4 INCHES; 6X6 ROOF LOOK-OUTS - ROTTING AT 6X6 COLUMN, FASTENED WITH NAILS ONLY, SCABBED; ROOF HATCH - MISSING;PERMIT REQUIRED; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS OF WALLS HAVE LOOSE AND MISSING MORTAR. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | WOOD PICKET FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | WEST ELEVATION HAS A NEWER CONSTRUCTED TWO STORY WOOD PORCH CONSTRUCTED WITHOUT PLANS OR PERMITS. OBTAIN PERMITS WITH PLANS. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO FRONT, REAR AND SIDE EXTERIOR ENTRY DOORS AND WALKWAYS. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES. ALL EXTERIOR LIGHT FIXTURES AND SUPPORT BOXES MUST BE WEATHERPROOF. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 6418 S EBERHART AVE | COMPLAINT | FAILED | View | |
PIGEONS-NESTING | PIGEONS ROOSTING ON 2ND FLOOR 6X6' BEAMS | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PORCH REAR BUTT JOINED COLUMNS LEDGERS NOT BOLTED GUARDRAILS LOOSE UNDERSIZED FOUNDATIONS 8 INCHES 2X6 JOISTS OVER 8' SPAN SWAYS PERMITS REQUIRED FOR REPAIRS STRINGERS OVERCUT NOT BOLTED HANDRAILS LOOSE | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF ROTTING AT EDGES NEAR 6X6 COLUMN | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT APARTMENT | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 6418 S EBERHART AVE | COMPLAINT | FAILED | View | |
REPAIR DOOR, INT. | FRONT ELEVATION /INTERIOR [FOYER] DOOR - MISSING; | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | PROVIDE SEPERATE PANEL AND METERING TO SERVE ALL BUILDING COMMON AREA LOADS 18-27-210.25 | 6418 S EBERHART AVE | COMPLAINT | FAILED | View |