The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SAFE WORKING CONDITIONS | APARTMENT 3A PILOT LIGHT WON'T STAY ON | 8112 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | REAR DOWNSPOUT AT NORTH BROKEN (18-39-1101.2.1) | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | FRONT STONE SILLS-WASHED OUT MORTAR | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED-1999 THRU 2006 (7YRS) | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR OR REPLACE | REAR DOWNSPOUT AT NORTH BROKEN (18-39-1101.2.1) | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
PARAPET | FRONT AND SOUTH ELEVATION PARAPET WALL - OPEN MORTAR JOINTS. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT AND SOUTH EXTERIOR WALL - WASHED OUT MORTAR JOINTS AND STEP FRACTURES. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | FRONT EXTERIOR WALL - STONE CORNICE PUSHING OUTWARD AND CRACKS FORMED ON CORNICE. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION - AT ALL LEVELS LINTELS BOWED. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR FENCE | REAR - CHAINLINK FENCE LEANING. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | FRONT EXTERIOR WALLS - WINDOW SILLS SHIFTED AND WASHED OUT MORTAR JOINTS. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | TWO - 3 STORY WOODEN PORCHESNORTH AND SOUTH PORCHES - 14 FOOT HANDRAIL SPAN FROM GRADE TO 2ND FLOOR, LOOSE PICKETS, NOTCHED OUT 6X6 COLUMNS, 16 INCH LAP JOINTS, COLUMNS TWISTING AND NOT PLUMB, TREAD AND WINDER BOARDS WARPED AND SPLITING HAZARDOUS, TREAD WINDERS NAILED TO RISER BOARDS, 3RD FLOOR STAIRS EVEN RISER HEIGHTS, ALL STAIR STRINGERS NAILED TO BLOCKING, JOISTS MISSING HANGERS, ALL CONNECTIONS ARE NAILED ONLY, FOOTING PADS BROKEN, 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB. OBTAIN PERMIT FOR REPAIRS. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | TWO - EXTERIOR STAIRSSOUTH STAIRS - 12 FOOT HANDRAIL SPAN, TREAD BOARDS LOOSE, SPLITTING AND DEFLECT UNDER PRESSURE, ALL CONNECTIONS NAILED AND NAILS STICKING OUT.NORTH STAIRS - 12 FOOT HANDRAIL SPAN AND ALL CONNECTIONS NAILED AND NAILS STICKING OUT. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY AND NO RESPONSE UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 8112 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |