The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP/REMOVE NUISANCE | REAR YARD - JUNK AND DEBRIS STOCKPILED THROUGHOUT. REAR ELEVATION /2ND FLOOR PORCH LANDING - JUNK AND DEBRIS SCATTERED THROUGHOUT. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION /EXTERIOR STAIR FROM GRADE TO BASEMENT - MISSING HANDRAIL. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ELEVATION /1-STORY EXTERIOR WOOD PORCH SYSTEM FROM GRADE TO 2ND FLOOR - FOUNDATION STATUS UNKNOWN; 4X4 COLUMNS OVERSPANNED WITH NO 1/2 LAP JOINTS; RIM JOISTS UNDERSIZED, SAGGING AND FASTENED TO COLUMNS USING NAILS ONLY IN SOME LOCATIONS; STAIR RUN PULLING AWAY FROM 2ND FLOOR LANDING WITH LARGE GAP AT TOP [TRIP HAZARD]; WOOD DECKING LOOSE AND LEANING OUT OF LEVEL NEAR EAST ELEVATION; HAND AND GUARD RAILS ONLY 30" IN HEIGHT, LOOSE AND PULLING AWAY FROM PORCH STRUCTURE; SPINDLES AT STAIR RUN OVER SPACED. PLANS AND PERMIT REQUIRED FOR REAR PORCH SYSTEM REPLACEMENT. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR YARD /ELEVATED WOOD WALKWAY - LOOSE, BROKEN SECTIONS; SOFT, SAGGING PLANKS AT MULTIPLE LOCATIONS [TRIP HAZARD]. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR ELEVATION /1-STORY WOOD PORCH SYSTEM FROM GRADE TO 2ND FLOOR - ERECTED WITH NO PLANS OR PERMIT ON FILE. PLANS AND PERMIT NOW REQUIRED FOR PORCH SYSTEM REPLACEMENT. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAST ELEVATION/ EAVE - ROTTED WITH PEELING PAINT. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINTS OF ONLY 1 EGRESS AND HOLE IN CEILING. UNABLE TO INSPECT INTERIOR STAIRWAYS AND REAR PORCH. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | WEST AND EAST ELEVATIONS/ GUTTERS - RUSTED. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1ST FLOOR STAIRWAY - METAL RAILINGS - LOOSE AND PULLING. | 5054 W NEWPORT AVE | COMPLAINT | FAILED | View |