REPAIR EXTERIOR WALL | EXTERIOR WALLS-NORTH AT GRADE; WASHED OUT MORTAR. SOUTH AT (2)-LARGE HOLE. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEYS-WASHED OUT MORTAR. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEYS-MISSING CAPS. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS-MISSING HANDRAIL. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST PORCH-BROKEN CONCRETE STOOP. NORTH 4X4 COLUMN IS ONLY SET ON TOP OF A 4 INCH X 4 INCH X 3 INCH PIECE OF LUMBER. ROTTED DECK JOIST. STRINGERS ARE ONLY NAILED INTO JOIST BRIDGING. LOOSE RAILS. MISSING HANDRAIL FROM (G) TO (B). IMPROPER CONNECTIONS-MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. ONLY PERMIT REQUIRED FOR REPAIRS TO EAST PORCH. REAR ENCLOSED PORCH-CENTER COLUMN AT GRADE IS PULLING AWAY FROM THE BEAM; 3 INCH X 4 INCH POSTS ADDED FOR ADDTIONAL SUPPORT; GAPS FILLED WITH CAULK. HEADER BEAM SUPPORTING THE FIRST FLOOR LANDING IS PULLING AWAY FROM THE EXTERIOR BRACING. UNDERSIZED 2X6 JOISTS SPAN 13 FEET 2 INCHES. IMPROPER CONNECTIONS-MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. PLANS AND PERMIT REQUIRED FOR REPAIRS TO ENCLOSED PORCH. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | BASEMENT AREAWAY-MISSING GUARDRAIL. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT-TENANT ASLEEP. APT.1-NO RESPONSE. APT.2-LEASE HOLDER; NOT HOME. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF: MICE INFESTED AT APT.1. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN IS NOT POSTED. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR-PAINTED. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT GATE DOUBLE CYLINDER LOCKS. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION EXTERIOR WALL AT GRADE LOOSE AND WASHED OUT MORTER JOINTS SPALLING BRICKS. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR COPING | EAST ELEVATION COPING STONES HAVE WASHED OUT MORTER JOINTS. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION FRONT STAIRS 2X6 JOIST ARE ONLY NAILED TO RIM JOIST,ROTTED AND SAGGING,4X4 COLUMNS SITTING ON CONCRETE SLAB FOOTINGS UNKNOWN AND STRINGERS FASTENED WITH NAILS ONLY OBTAIN PERMIT BEFORE MAKING REPAIRS. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST AND 2ND FLRS FRONT ENTRY DOORS MISSING PEEP HOLES. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR HALLWAY MISSING SMOKE DETECTOR. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS/GRADE TO BASEMENT-MISSING HAND RAIL. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION/EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARDRAIL. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ELEVATION/BASEMENT EXTERIOR DOOR-MISSING EXTERIOR TRIM. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | FRONT EXTERIOR BASEMENT DOOR-BROKEN FRAME AT LATCH. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT APARTMENT/LIVING ROOM SOUTH WALL-HOLE IN BASEBOARD. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION/EXTERIOR 1 STORY PORCH.4X4 COLUMNS SET IN CONCRETE,FOUNDATIOIN STATUS UNKNOWN.LEDGER BEAM BOLTS ARE ONLY SPACED 36 INCHES APART.STRINGERS ARE ONLY FACE NAILED AT TOP CONNECTION WITH SCABBED LUMBER FOR SUPPORT,TREADS ARE SPLITTING.METAL RAILINGS ARE LOOSE AND PULLING,GUARD RAILS ARE ONLY 32 INCHES IN HEIGHT.///REAR ENCLOSED 2 STORY WOODEN PORCH. 6X6 COLUMNS SET IN CONCRETE FOUNDATION STATUS UNKNOWN.BEAM AND COLUMN CONNECTIONS ARE ONLY TOE NAILED AT FIRE CUTS,PULLING APART.NORTH COLUMN SET ON SCABBED WOODEN BLOCK,ROTTED AT BEAM CONNECTION WITH 2X4 TEMPORARY SUPPORT.2X6 JOISTS SPAN 14 FEET.STRINGERS ARE ONLY FACE NAILED AT TOP CONNECTION.2ND FLOOR GUARD RAIL IS ONLY 34 INCHES IN HEIGHT. PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCHES. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING/NO ENTRY TO 1ST,2ND FLOOR APARTRMENTS,UNVERIFIED DETECTORS AND CONDITIONS. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | INSTALL PUBLIC AREA METER AND PANEL. RESOLVE MIXED CIRCUIT ISSUES. PUBLIC AREA CIRCUITS TIED INTO BASEMENT PANEL. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALLS-WASHED OUT, LOOSE MORTAR. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | BASEMENT KITCHEN GFCI | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | BASEMENT APARTMENT/MICE DROPPINGS THROUGHOUT. | 2336 S RIDGEWAY AVE | COMPLAINT | FAILED | View |