Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY 1ST FLOOR APARTMENT- FRONT ROOM 66F , REAR BEDROOM 67F, . HEATING SYSTEM IS ON AT TIME OF INSPECTION, HEAT IS INSUFFICIENT. 3649 W LEXINGTON ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT ELEVATION OWNERS I.D.SIGN NOT POSTED. 3649 W LEXINGTON ST COMPLAINT PASSED View
REPLACE D&H PORCH REAR PORCH COLUMNS SCABBED,ROTTED AT FIRE CUTS,LOOKOUTS ROTTED AT FIRE CUTS,MISSING METAL TIESAT BEAM POCKETS,FLOOR JOISTS UNDERSIZED FOR SPAN,STRINGERS MISSING BOLTS,TREADS ROTTED,LOOSE,RAILINGS TOO LOW LOOSE,COLUMNS MISSING FOOTINGS,EXCESSIVE GAP IN FIRE CUT AREAS,IMPROPER SPLICE CONNECTION.PORCHIN D&H CONDITION.SUBMIT PLANS AND OBTAIN PERMIT TO REBUILD REAR PORCH. 3649 W LEXINGTON ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR TO VERIFY DETECTORS. 3649 W LEXINGTON ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO ACCESS TO CHECK OCCUPANCY OR DETECTORS. 3649 W LEXINGTON ST COMPLAINT FAILED View
REPAIR FENCE REAR FENCE CHAIN LINK, NO TOP SUPPORT RAIL AND BENT WIRE. 3649 W LEXINGTON ST COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE REAR GAGE DOUBLE CYLINDER DEADBOLT LOCK. 3649 W LEXINGTON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH GRADE TO 2ND DILAPIDATED, ROTTEN SECTIONS IMPROPER FOOTINGS. NO JOIST HANGERS. NO LEDGER BOLTS INSUFFICIENT LAP OUT AT UPRIGHT COLUMNS AND BOLT CONNECTIONS GAP AT BALUSTERS TO TREADS AT 2ND LEVEL. COLUMNS OUT OF PLAIN. 3649 W LEXINGTON ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMIT REQUIRED FOR REPLACEMENT REAR PORCH. 3649 W LEXINGTON ST COMPLAINT FAILED View
ABANDONED REFRIGERATOR REAR YARD ABANDONED REFRIGERATOR. 3649 W LEXINGTON ST COMPLAINT FAILED View