The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANTBUILDING-REGISTER/SECURE | BUILDING OCCUPIED | 4620 S EVANS AVE | COMPLAINT | CLOSED | View |
VACANT BUILDING - REGISTER | BUILDING OCCUPIED | 4620 S EVANS AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | COLUMNS SET ON CONCRETE BLOCK. FOUNDATION STATUS UNKNOWN. BEAMS ATTCHED TO COLUMNS WITH NAILS ONLY. COLUMNS OVERNOTCHED AT RIM JOISTS. RIM JOISTS ATTACHED TO COLUMNS WITH NAILS ONLY. DECK JOISTS ATTACHED TO RIM JOISTS WITH NAILS ONLY. STRINGERS ATTACHED TO EXTERIOR WALL, DECK JOISTS AND RIM JOITS WITH NAILS ONLY. UNDERSIZED 2" X 8" DECK JOISTS SPAN 9'. RAIL SECTIONS ARE ONLY 36" HIGH. RAILS ATTACHED TO EXTERIOR WALL, COLUMNS AND POSTS WITH NAILS ONLY. TREAD DEPTH IS ONLY 9 1/4". PICKETS ARE LOOSE AND MISSING. 3/4" DECKING IS BUCKLED AND ROTTEN. SUBMIT PLANS AND OBTAIN PERMIT TO REPAIR OR REPLACE REAR PORCH SYSTEM. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WATER DAMAGED PLASTER. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | FLOOR TILES MISSING. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID. SIGN NOT POSTED. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | WATER LEAKING. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | STRINGER ROTTEN AND CRACKED AT BOTTOM. STAIR MEMBERS COVERED - NOT ABLE TO EXAMINE CONSTRUCTION METHODS. MAKE ARRANGEMENTS. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR-OUT OF SERVICE; MISSING BATTERY AND FACE PLATE. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO 1ST FLOOR AND BASEMENT TO CHECK OCCUPANCY,DETECTORS,EAST ELEVATION,NEW FRONT PORCH BUILT WITH PERMIT #100366907 ISSUED 10/07/10.NO PLANS OR PERMIT ON SITE.SET UP APPOINTMENT FOR PERMIT INSPECTION. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY,MISSING SMOKE DETECTOR. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | 1ST FLOOR UNIT,BATHROOM CEILING,WATER DAMAGED PLASTER,FLOOR TILE MISSING,WATER LEAKING BATHROOM CEILING. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING NO OWNERS I D SIGN POSTED. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION,EXTERIOR STAIRS,MISSING HAND RAIL. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD,JUNK AND REFUSE ACCUMALATING. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | SOUTH ELEVATION,AREA BREEZEWAY WALLS EXPOSED METAL LATH. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION,REAR PORCH,COLUMNS SET ON CONCRETE BLOCKS,BEAMS AND COLUMN CONNECTION TOE NAILED ONLY,COLUMNS OVER NOTCHED,RIM JOIST FACE NAILED ONLY,DECK JOISTS FACE NAILED ONLY,RAILS ARE 36'' HIGH LOOSE AND PULLING WITH PICKETS MISSING,RAIL ARE TOE NAILED TO SUPPORTS,DECKING BOARDS ARE ROTTED.PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS-MISSING HANDRAILS. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | DOWNSPOUT-MISSING; DRAINING WATER ONTO THE PORCH. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | ELECTRICAL METER-OPEN SOCKET; EXPOSED WIRING / COMPONENTS. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS AND COMPLIANCE ON PREVIOUS VIOLATIONS OF: INSPECTION #10248357. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMIT FOR FRONT AND REAR PORCH | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPAIR COPING | SOUTH COPING STONE MISSING | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST EAST CRACKING PANE | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | SERVICE ENTRY RISER BROKEN AT HUB, D&H | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | INSTALL PUBLIC METER PANEL | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 4620 S EVANS 2ND FLOOR BACK BEDROOM 55 DEGREES | 4620 S EVANS AVE | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | FURNACE OUT OF SERVICE AT TIME OF INSPECTION GAS SERVICE SHUT OFF BECAUSE DANGEROUS CONDITION AT FURNACE | 4620 S EVANS AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR | 4620 S EVANS AVE | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | USING COOKING STOVE AS HEATING DEVICE | 4620 S EVANS AVE | COMPLAINT | PASSED | View |
WINDOW REPAIR FOR AIR SEEPAGE | WINDOW FRAMES-GAPS AND CRACKS,DRAFTY WINDOWS,AIR SEEPAGE | 4620 S EVANS AVE | COMPLAINT | PASSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | WATER TEMPERATURE 53 DEGREES GAS SERVICE-SHUT OFF NO HOT WATER FURNISHED DANGEROUS CONDITION ANT HOT WATER TANK | 4620 S EVANS AVE | COMPLAINT | PASSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | WATER SHUT OFF. NO HOT WATER PROVIDED. | 4620 S EVANS AVE | COMPLAINT | CLOSED | View |
PROVIDE COLD WATER TO FICTURES | WATER SHUT OFF. NO COLD WATER PROVIDED. | 4620 S EVANS AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | 2ND FLOOR THE GAS CO DISCONNETED THE FURNACE AND WATER HEATER DUE TO CLOGGED FLUE AND CHIMNEY. | 4620 S EVANS AVE | COMPLAINT | CLOSED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR IS USSING STOVE TO KEEP WARM. | 4620 S EVANS AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANE-BROKEN. | 4620 S EVANS AVE | COMPLAINT | FAILED | View |
OPEN | 4620 S EVANS AVE | PERMIT | PASSED | View |