Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:12 PM
PIN: 16231100250000
Property Address: 1316 S INDEPENDENCE BLVD
City - Zip: CHICAGO - 60623
2023 Property Class:
2023 Township: -
2023 Neighborhood:
2023 Tax District:
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 31 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING OWNERS'S ID SIGN NOT POSTED 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
NO POSTED ADDRESS BUILDING ADDRESS NOT POSTED 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR BALCONY WEST ELEVATION PEELING PAINT, CRACKS AT CEILING WAHSED OUT MORTAR AT PLANTER'S LEDGE ON 1ST FLR. 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR WEST ELEV. FRONT STAIRS CRACKED SPALLED. 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR LINTELS WEST ELEV.BALCONIES RUSTING LINTELS 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR LINTELS WEST ELEV. BALCONIES RUSTING LINTELS 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
NO KEY TO USE EXIT DOOR WEST ELEV. DOUBLED KEY LOCK ON SIDE GATE 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR EXTERIOR DOOR HARDWARE WEST ELEV. DOWNSPOUT RUSTING 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPLACE D&H PORCH EAST ELEV. REAR PORCH 6X6 COULMNS FLAKING AWAY FROM BEAMS AT 1ST 2ND FLOORS STEEL ANGLE BRACKETS MISSING AT BEAM/COLUMN CONNECTIONS 2X8 JOISTS SPAN 9'-6" BOLTS MISSING AT STRINGERS LEDGER BOARDS RAILS; SPLICE JOINTS ARE ONLY 16" WITH NO BOLTS RAIL HEIGHT IS ONLY 36" AND LOOSE THRU OUT RAIL SECTION MISSING ON 2ND FLR. DABGEROUS AND HAZARDOUS TREADS ARE WORN SPLIT AND BROKEN AT EDGE; PLANS AND PERMIT REQUIRED FRO REPAIRS TO REAR PORCH. 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
SERVICE WALK, PASSAGE, AREAWAY EAST ELEV. AREAWAY CRACKED UNEVEN 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
CUT OR REMOVE HIGH WEEDS SOUTH ELEV. HIGH WEEDS ALONGSIDE SERVICEWALK 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
CHIMNEY CAPPING SOUTH ELEV. CHIMNEY CAP MISSING 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR EXTERIOR WALL SOUTH ELEV. WASHED OUT MORTAR, SPALLING BRICKS. 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR OR REPLACE SOUTH EAST, ELEV. BARS OVER WINDOWS ARE RUSTING 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
INSTALL EXTRA SMOKE DETECTORS 1ST FLR APT SMOKE DET. MISSING AT FRONT OF UNIT 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID 1ST FLR APT. MISSING ADDITIONAL CARBON MONOX. DET. 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR FLOOR 1ST FLR APT MOLD DEVELOPING ON FLR. BOARDS 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR INTERIOR STAIR SYSTEM INT. STAIRWELL 2ND FLR NEWEL CAP MISSING 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS INT. STAIRWELL SMOKE DET. MISSING 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
STOP/REMOVE NUISANCE WEST ELEVATION BACKYARD DOG FECES. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION 3 STORY WOOD PORCH 6X6 COLUMNS ARE OVERNOTCHED AND FASTENED AT BEAM TO COLUMN CONNECTIONS WITH LIGHT GAUGE METAL BRACKETS.STATUS OF FOUNDATIONS UNKNOWN.RAILINGS ARE VERY LOOSE AND UNSTABLE.STRINGERS FASTENED WITH COMMON NAILS.PLAN AND PERMIT REQUIRED FOR REPAIRS. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# I.D SIGN MISSING ADDRESS. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 3RD FLOOR AT CEILING SMOKE DETECTOR MISSING. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR EAST AND WEST ELEVATION GATES HAVE DOUBLE KEY LOCKS. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO 1ST FLOOR APARTMENT TO VERIFY COMPLAINT OF MOLD IN WALLS. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST FLOOR APARTMENT DISCONNECTED/CAPPED GAS LINE ON FURNACE. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR INTERIOR ALTERATIONS OF EXISTING 3 STORY MASONRY BUILDING INCLUDING BUTNOT LIMITED TO:ERECTING NEW PARTITIONS AT BASEMENT.REMOVING DRYWALL FROM FIRST, SECOND AND 3RD FLOOR. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED EAST ELEV. GARAGE CRACKS IN EXT. WALL FASCIA BOARD ROTTING; SERVICE DOOR AND FRAME ROTTING. 1316 S INDEPENDENCE BLVD COMPLAINT CLOSED View
REPAIR/REBUILD GARAGE OR SHED WEST ELEVATION OVERHEAD GARAGE DOOR MISSING. 1316 S INDEPENDENCE BLVD COMPLAINT FAILED View