The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO POSTING OF OWNERSHIP | 3251 W MAYPOLE AVE | COMPLAINT | PASSED | View |
SEAL CONDUIT OPENING | 3251 PATCH TELEPHONE CABLE OUTSIDE REAR | 3251 W MAYPOLE AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | IMPROPERLY INSTALLED OR NO DISCHARGE PIPE FOR HOT WATER TANK T&P VALVES IN UNITS A-2, B1, B2, C1, C2, D1, D2, AND THROUGHOUT | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | VERIFY GROUNDING ELECTRODE CONDUCTOR IS BONDED AND LANDED PROPERLY ON COLD WATER SERVICE | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE ALL CLOSET LIGHTS IN ALL UNITS WITH GLOBE TYPE FIXTURES (14E-5-570.10 (F) /LIGHT INOPERABLE IN UNIT B2 FRONT ENTRY WAY AND 2ND FLOOR HALL UNIT C1 LIGHT IN HALLWAY GLOBE MISSING IN LIMIT D1 KITCHEN AND DINING ROOM,UNIT C2 GLOBE MISSING IN HALLWAY KITCHRN AND DINING ROOMS UNIT D2 LIGHT FIXTURE INOPERABLE | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEP HOLE- D2 14X-4-403.1.4 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIR SYSTEMS METAL SIGNS OF RUST AND DETERIORATED SEC# 14X-5-505.9.1.3 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | FAUCETS CONTINUOUSLY DRIPPING IN KITCHEN OR BATHROOM IN UNITS A2, B2, C1, C2, D1 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | EMPLOY LICENSED AND BONDED PLUMBING CONTRACTOR TO PERFORM PLUMBING WORK | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SUPPLEMENTAL GROUND | PROVIDE SUPPLEMENTAL GROUND | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | CARPET UNSANITARY D2, C2 14X-1-103 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROVIDE | NO SAFE PAN UNDER HOT WATER HEATERS LOCATED IN MECHANICAL IN UNITS A-2, B1, B2, C1, C2, D1, D2 AND THROUGHOUT 18-29-504.8 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH DEVICE | TOILET CONTINUOUSLY RUN IN UNITS A2 AND C2 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE TRAP | DEFECTIVE S-TRAPS USED AT KITCHEN SINKS IN UNITS A1-2, B1, B2, C1, C2, D1, D2 AND THROUGHOUT | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | COVERS MISSING ON RECEPTACLES IN UNIT A2 NORTH BEDROOM/UNIT B2 2ND FLOOR NORTH AND WEST BEDROOMS | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | SMOKE DETECTOR MISSING FROM UNIT C1 HALLWAY WITH EXPOSED WIRES HANGING CEILING D&H | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | INSTALL PROPER AND LEGIBLE PANEL SCHEDULES IN ALL UNITS | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
APPLIANCE INSIGHT DISCONNECT | INSTALL APPLIANCE DISCONNECT SWITCH FOR DISHWASHERS IN ALL UNITS | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROVIDE ELECTRICAL PERMIT IN ORDER TO CORRECT VIOLATIONS 14A-4-404.6 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View | |
DEFECTIVE OUTLETS | UNIT A2 RECEPTACLE INOPERABLE IN SOUTH BEDROOM/UNIT B2 SWITCH UPSIDE DOWN IN 2ND FLOOR BATHROOM | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI PROTECTION FOR ALL RECEPTACLES SERVICING KITCHEN COUNTER AREA IN ALL UNITS AND VERIFY ALL BATHROOM GFCI RECEPTACLES ARE FUNCTIONING | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | FLOOR MISSING SECTIONS OF TILE AND OR ROTTEN WOOD SUBFLOOR-D2 KITCHEN FLOOR, C2 ENTRY WAY BATHROOM 1ST AND 2ND FLOORS 14X-3-304.4 REFRIGERATOR LEAKING- D1 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT BEFORE ANY REPAIRS ARE MADE | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | FURNACE ROOMS TYPICAL THROUGHOUT ENTRY TO 1B,B2,D1,C1,C2,D2 COMPROMISED FIRE SEPARATION FOAM USED AROUND PIPES (VERTICAL FIRE SEPARATION) 14B-4-420.2 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | EVIDENCE OF MICE A2,D2,C1,D2,B2 14X-3-308 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
WORKING SPACE | UNIT D2 HOT WATER HEATER DIRECTLY IN FRONT OF ELECTRICAL PANEL IN MECHANICAL ROOM D&H | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | SEPARATE CLASS 1 AND CLASS 2 WIRING IN MECHANICAL ROOM JUNCTION BOXES USED FOR LOW VOLTAGE FOR FURNACES IN ALL UNITS D&H | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
OPEN | NO FLOOR DRAINS LOCATED IN MECHANICAL ROOMS IN UNITS A-2, B1, B2, C1, D1, D2, AND THROUGHOUT 18-29-412 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF EVIDENCE OF WATER PENETRATION IN UNITS 3251-1B,A2, SEC# 14X-303.1.1 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BEEPING, HANGING AND OR MISSING BATTERY SMOKE DETECTORS A2,B2, C1 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | PROVIDE ADDITIONAL CARBON MONOXIDE DETECTORS IN UNITS FOR FURNACE ROOMS MISSING DETECTORS- 1B,A2,B2,D1,C1,C2,D2 14X-5-504.9 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOWS C-2, 14X-3-303.13 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | BATHROOM LAVATORY CABINET ROTTED AND UNSTABLE IN UNITS C2 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | MISSING WINDOW SCREENS THROUGHOUT 14X-1-103.3 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED FLEXIBLE WATER SUPPLY LINES AT KITCHEN SINKS, TOILETS AND BATHROOM LAVATORIES IN UNITS A-2, B1, C1, C2, D1, D2 AND THROUGHOUT | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | LOW HOT WATER PRESSURE AT KITCHEN AND BATHROOMS UNIT A2, C1, C2, | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILING WATER DAMAGED -A2 KITCHEN 14X-3-304.3 | 3251 W MAYPOLE AVE | COMPLAINT | FAILED | View |