Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | SOUTH ELEVATION / 2 STORY WOOD PORCH / COLUMNS ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. COLUMNS - DOUBLE NOTCHED. HALF LAP JOINTS MEASURE ONLY 16 INCHES AND HAVE UNDERSIZED 3/8 INCH BOLTS. SINGLE 2X8 BEAMS SPAN UP TO 9 FEET 4 INCHES AND ARE FASTEND TO NOTCHED OUT COLUMN WITH NAILS ONLY. DECK JOISTS - FASTENED WITH NAILS ONLY. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. HANDRAILS - LOOSE AND MOVE WHEN SHAKEN. GUARD RAILS SPAN UP TO 9 FEET 4 INCHES. NORTH WOOD PORCH / COLUMNS ERECTED ON CONCRETE SLAB. FOUNDATION STATUS - UNKNOWN. GUARDRAILS - MEASURE ONLY 30 INCHES AND SPAN UP TO 10 FEET ONG. ALL RAILINGS - FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE REAR 2 STORY WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 605 E 41ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / EXTERIOR WALL - MASONRY FRACTURES. | 605 E 41ST ST | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 605 E 41ST ST | PERMIT | PASSED | View | |
OPEN | 605 E 41ST ST | PERMIT | PASSED | View | |
OPEN | 605 E 41ST ST | PERMIT | PASSED | View | |
SEE INSPECTOR COMMENTS | PROVIDE AT LEAST (1) 20 AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEOTACLES (SHALL SERVE NO OTHER OUTLETS) - NO ACCESS TO GFCI 14E-2-210.11(C)(2) 14E-2-210.52(F) | 605 E 41ST ST | PERMIT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE THE REQUIRED GFCI PROTECTION FOR PERSONNEL FOR DISH WASHERS IN DWELLING UNITS - NO ACCESS TO GFCI'S 14E-2-210.8(D) | 605 E 41ST ST | PERMIT | PASSED | View |
SEE INSPECTOR COMMENTS | LIGHT FIXTURE SHALL BE PROPERLY GROUNDED - NO CONTINUITY BETWEEN LIGHT FIXTURE AND JUNCTION BOX 14E-4-410.44 | 605 E 41ST ST | PERMIT | PASSED | View |
SEE INSPECTOR COMMENTS | THE GROUNDED CONDUCTOR (NEUTRAL) SHALL NOT DEPEND ON WIRING DEVICES SUCH AS LAMPHOLDERS AND RECEPTACLES TO MAINTAIN CONTINUITY - NEUTRAL TO BE PIGTAILED 14E-3-300.13(B) | 605 E 41ST ST | PERMIT | PASSED | View |
SEE INSPECTOR COMMENTS | METAL RACEWAYS AND METAL ENCLOSURES SHALL BE MECHANICALLY JOINED TOGETHER AND CONNECTED TO BOXES, FITTINGS AND CABINETSSO AS TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY - NO RACEWAY BETWEEN BOXES AT LAUNDRY ROOM 14E-3-300.10 | 605 E 41ST ST | PERMIT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE MINIMUM WORKING SPACE AND CLEARANCES AROUND ELECTRICAL EQUIPMENT - NEED PROPER WORKING SPACE AT 1ST FLOOR PANEL 14E-1-110.26 | 605 E 41ST ST | PERMIT | PASSED | View |