Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 2:41 PM
PIN: 21311190120000
Property Address: 8141 S KINGSTON AVE
City - Zip: CHICAGO - 60617
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70100
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS SMOKE DETECTOR-MISSING. 8141 S KINGSTON AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING WALLS-(LIVING ROOM @ FRONT WINDOWS)-WATER DAMAGE; FLAKING PLASTER. (NORTH BEDEROOM @ WINDOW AND EAST BEDROOM @ EAST WALL) MILDEW. 8141 S KINGSTON AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHER-EXPIRED SERVICE TAG. 8141 S KINGSTON AVE COMPLAINT FAILED View
REMOVE UTILIZED AS HABITABLE LIVING SPACE (BEDROOM) (SEC.7-28-060). 8141 S KINGSTON AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY EXIT DOOR-BLOCKED WITH FURNITURE AND PERSONAL ITEMS. 8141 S KINGSTON AVE COMPLAINT FAILED View
REPAIR DOWNSPOUT DOWNSPOUT-BROKEN; DEBRIS PROTRUDING OUT. 8141 S KINGSTON AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH-COLUMNS SPLICES ARE ONLY 16 INCHES WITH ONLY THREE BOLTS; SOUTH COLUMN WITH EXCESSIVE SPLITTING OF THE LUMBER AT THE SPLICE. EDGE BEAMS ARE ONLY NAILED AT COLUMNS AND LEDGER JOISTS CONNECTIONS. 2X8 JOIST HANGERS UTILIZED FOR 2X12 DECK JOISTS. 4X6 POSTS ARE ONLY NAILED AT RIM JOISTS CONNECTIONS. STRINGERS ARE ONLY NAILED AT COLUMN CONNECTIONS. LOOSE GUARDRAIL AT (3); 2X4 MEMBER UTILIZED IN LIEU OF 4X4 INTERMEDIATE POSTS. MOST RAILS ARE ONLY TOE NAILED AT THE CONNECTIONS. GUARDRAIL MISSING AT BASEMENT AREAWAY PERIMETER. (PORCH ENCLOSURES) 6X6 COLUMNS ARE SET ON UNDERSIZED 7X7 CONCRETE BASES; SOUTH ENCLOSURE COLUMNS ARE ROTTED. BEAMS ARE ONLY TOE NAILED AT COLUMN CONNECTIONS. UNDERSIZED 2X8 DECK JOISTS SPAN 11FEET 4INCHES. PLANS / PERMIT REQUIRED FOR REPAIRS. 8141 S KINGSTON AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION BUILDING-NOT REGISTERED FROM: 2007 THRU 2011. 8141 S KINGSTON AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE-UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. 8141 S KINGSTON AVE COMPLAINT FAILED View