The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALL - STRUCTURAL CRACK FROM BASEMENT WINDOW TO PARAPET WALL; WASHED OUT MORTAR | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
REPAIR GUTTER | FRONT PORCH - WATER LEAKING AT CEILING SOFFIT FROM 2ND FLOOR BALCONY | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - LEANING SLIGHTLY | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
BELOW GRADE +2' - BASEMENT | BASEMENT - GLASS BLOCK WINDOWS FLUSH WITH GRADE | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
BELOW GRADE +2' - BASEMENT | BASEMENT - GLASS BLOCK WINDOWS FLUSH WITH GRADE | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
DEMO DEBRIS | LUMBER, DEBRIS UNDERNEATH REAR PORCH | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR APARTMENT - SMOKE DETECTOR - NOT WORKING AT TIME OF INSPECTION; BEEPING | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | REAR PORCH - DISCARDED FURNITURE, CRATES ON 3RD FLOOR DECK; TELEVISION ON 2ND FLOOR DECK | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | LUMBER, DEBRIS UNDERNEATH REAR PORCH | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | LUMBER, DEBRIS UNDERNEATH REAR PORCH | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - STRUCTURAL CRACK FROM BASEMENT WINDOW TO PARAPET WALL; WASHED OUT MORTAR | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - LEANING SLIGHTLY | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
REPAIR GUTTER | FRONT PORCH - WATER LEAKING AT CEILING SOFFIT FROM 2ND FLOOR BALCONY | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR APARTMENT - SMOKE DETECTOR - NOT WORKING AT TIME OF INSPECTION; BEEPING | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | LUMBER, DEBRIS UNDERNEATH REAR PORCH | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | CHIMNEY - CAP MISSING | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ENTRY DOOR - HASP (WITHOUT LOCK) INSTALLED ON DOOR; POTENTIAL OBSTRUCTION. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ENTRY DOOR - HASP (WITHOUT LOCK) INSTALLED ON DOOR; POTENTIAL OBSTRUCTION. | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | CHIMNEY - CAP MISSING | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCH - DISCARDED FURNITURE, CRATES ON 3RD FLOOR DECK; TELEVISION ON 2ND FLOOR DECK | 3051 W CULLERTON ST | COMPLAINT | CLOSED | View |
REPAIR OR REPLACE | 2ND FLOOR BATHROOM VANIT DRAWER BROKEN. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION 3 STORY WOOD PORCH STATUS OF FOUNDATIONS UNKNOWN.2X6 JOIST SPANNING 7'6". HANDRAILS ARE A LADDER TYPE DESIGN.6X6 COLUMNS OVERNOTCHED WITH 12" SPLICES AND FASTENED WITH 2 3/8 BOLTS.DOUBLE 2X6 RIM JOIST IS FASTENED WITH COMMON NAILS CONNECTED TO A SCABBED 2X4. MOST CONNECTIONS FASTENED WITH COMMON NAILS.PLAN AND PERMIT REQUIRED TO MAKE REPAIRS. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
MICE/RODENTS | 2ND FLOOR KITCHEN COUNTERTOP MICE DROPPINGS. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR FRONT ROOM 2 BROKEN SECTIONS OF HARWOOD FLOOR BOARDS. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION BOTH SIDES OF STAIRS CONCRETE WING WALLS HAVE LARGE CRACKS AND SHIFTING. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | SOUTH ELEVATION AT BOTTOM PORCH WALL HAS LARGE RAT HOLES. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | DANGEROUS AND HAZARDOUS REAR EXTERIOR 3 STORY PORCH / BEAMS- UNDERSIZED DOUBLE 2X6 BEAMS WITH SPANS UP TO 8 FEET. UNDERSIZED 2X6 DECK JOISTS SPAN 7 FEET 8 INCHES. STRINGERS FASTENED TO DECK JOISTS WITH NAILS ONLY.DECK JOISTS AT LANDINGS FASTENED WITH TOE NAILS ONLY. 2X6 LEDGER BEAM WITH BOLTS INTO EXTERIOR WALL AT 36 INCHES APART. TREADS ONLY 9+1/4 INCHES WIDE. UNDERSIZED 2X6 STAIR HEADER BEAMS SPAN 7 FEET 10 INCHES- WEAK, SAGGING, AND IN DANGER OF COLLAPSE AT ALL LEVELS. PLANS AND PERMIT REQUIRED TO REPLACE; DANGEROUS AND HAZARDOUS REAR EXTERIOR 3 STORY PORCH. | 3051 W CULLERTON ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING- OWNER'S ID SIGN POSTED. INCOMPLETE INFORMATION,MISSING MAILING ADDRESS. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | FRONT ELEVATION- FIRST FLOOR- MISSING SASH.[BOARDED UP WINDOW] | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY- SPALLED BRICKS,WASHED OUT MORTAR. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAPPING- BROKEN CAPPING- WASHED OUT MORTAR. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS. | 3051 W CULLERTON ST | COMPLAINT | FAILED | View |