The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 1427 S CENTRAL PARK AVE | COMPLAINT | CLOSED | View | |
OBSTRUCTIONS IN EXIT WAY | FRONT GATES - DOUBLE KEYED LOCKS | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION EXTERIOR WALL - OPEN WALL POCKETS UNDER PORCH; NORTH WALL - SPALLING BRICKS | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION - PARAPET WALL OPEN MORTAR JOINTS | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION - REAR BASEMENT STAIRS BROKEN CONCRETE | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OPEN WOOD PORCH - BROKEN CONCRETE AT BOTTOM STEP; IMPROPER RISER HEIGHTS; 6X6 BEAMS NOT CEMENTED INTO WALL POCKETS; COLUMN SPLICES 16" LONG WITH TWO BOLTS; 2X8 JOISTS UNDERSIZED FOR SPAN OF DECKS; STAIR TREADS 9 1/2" WIDE; HANDRAILS LESS THAN 36" HIGH; GUARDRAILS LESS THAN 42"HIGH; RAILS LOOSE WITH SPLIT WOOD; STAIR SYSTEM FROM 1ST TO 2ND FLOOR IMPROPERLY BUILT, UNSTABLE AND WEAK; STRINGERS NOT ATTACHED TO WALL; SCAB WOOD AT COLUMNS; ROOF LEVEL RIM JOIST AND BEAM ROTTED WOOD; PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OF REAR PORCH;WEST ELEVATION FRONT PORCH - NO VISIBLE FOOTINGS AT BASE OF COLUMNS; COLUMN TWISTING AT ROOF CONNECTION; STAIR STRINGER SPLIT WOOD; STRINGERS NAILED; LEDGER BOARD NOT BOLTED TO WALL; NO JOIST HANGERS; GUARDRAIL MISSING PICKETS; GUARDRAILS LESS THAN 42" HIGH; PERMIT REQUIRED FOR REPAIRS | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION RETAINING WALL - WASHED OUT MORTAR; STONES SHIFTED | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATION - FRONT GUARDRAIL AT BASEMENT LEANING;REAR AT BASEMENT STAIRS NO GUARDRAIL | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | FRONT AND REAR DOORS - NO VIEWING DEVICE | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT OR 1ST FLOOR AT TIME OF INSPECTION; UNVERIFIED CONDITIONS AND DETECTORS | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING ADDRESS NOT POSTED | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWELL - NO SMOKE DETECTOR | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | SOUTH AND WEST ELEVATION - IRON AND WOODEN FENCE OVER 5'-1" TALL, NO PERMIT ON FILE WORK WORK | 1427 S CENTRAL PARK AVE | COMPLAINT | FAILED | View |