The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
UNAPPROVED HEATING DEVICE | TENANT USING STOVE TO HEAT APT 1ST FLOOR. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION FALLING AND MISSING SECTIONS OF MASONRY FACADE | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR WOOD PORCH NORTH AND SOUTH COLUMNS MISSING CONCRETE FOUNDATIONS MISSPAN COLUMNS RESTING ON BOWING RETAINING WALLS,JOISTS AT LANDINGS MISSING HANGERS, SCABBED WOOD AT BEAM-COLUMN CONNECTIONS BEAMS NOTCHED INTO COLUMNS AND MISSING BOLTS AND METAL SEAT ANGLES BEAM POCKETS OPEN AT 2ND LEVEL DECKING SOUTH BEAM SUPPORTING 2ND LEVEL DECKING IMPROPERLY BEARING ON BEAM POCKET (1/4" BEARING) COLUMN SPLICE CONNECTIONS INADEQUATE GUARDRAILS BELOW 42" IN HEIGHT GUARDRAIL AT 2ND LEVEL LANDING LOOSE SOUTH END GUARDRAIL MISSING AT SOUTH END OF PORCH ABOVE BASEMENT STAIRS, STAIR STRINGER TO 2ND LEVEL CRACKED, VIEWED FROM UNDERSIDE, STAIR STRINGERS MISSING BOLTS FOR CONNECTION TO MASONRY WALL OBTAIN PLANS AND PERMIT FOR PORCH REPAIR OR REPLACEMENT | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | ELEVATION, EXTERIOR ENTRY DOOR MISSING KNOB | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
INSTALL DEAD BOLT LOCK | WEST ELEVATION, EXTERIOR ENTRY DOOR MISSING DEADBOLT | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION, 2ND LEVEL BROKEN WINDOW PANE | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FOUNDATION | REAR ELEVATION FOUNDATION WALL AT BASEMENT EXTERIOR STAIRS BOWING | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
REPAIR DOOR FRAME, MULLION | 1ST FLOOR APARTMENT, 2ND AND 3RD BEDROOM DOOR TRIM SEPARATING FROM WALL | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | 2ND BEDROOM 1ST FLOOR APARTMENT MOLD ON WALL | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | 1ST FLOOR APARTMENT, LIVING AND BEDROOM FLOORS HOLES FROM REMOVAL OF RADIATORS | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
FLUE PIPE CLEARANCE 6"X | 1ST FLOOR APARTMENT, FURNACE ROOM, MISSING FLUE PIPE COLLAR | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | 1ST FLOOR APARTMENT, FURNACE ROOM, TIRES WOOD CART, BIKE, STORED WITH 6" OF FURNACE | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | 1ST FLOOR APARTMENT, EVIDENCE OF LEAKING WATER UNDER KITCHEN AND BATHROOM SINKS | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT FOR PARTITIONS AND ALTERATIONS TO BASEMENT | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO BASEMENT APARTMENT ARRANGE INSPECTION OF BASEMENT APARTMENT | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | 1ST FLOOR APARTMENT, FURNACE ROOM, EXPOSED WIRING AT LIGHT SWITCH | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | INSTALL JOIST HANERS AT LANDINGS, INSTALL ANGLE IRON AND BOLTS AT BEAM TO COLUMN CONNECTIONS, SEAL BEAM POCKETS AT 2ND LEVEL, GUARD RAILS NOT 42 INCHES IN HEIGHT, BOLT STAIR STRINGERS TO FACE OF MASONRY WALL; OBTAIN PERMIT FOR REPAIRS, NO PLANS NEEDED | 6417 S EBERHART AVE | COMPLAINT | PASSED | View |
PARAPET | NORTH PARAPET WALL BROKEN CONCRETE,WEST AND NORTH PARAPET WALL MORTAR MISSING. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | CATCH BASIN - GROUND SINKING AROUND COLLAR; HOLE | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - SPALLING BRICKS; PAINT PEELING | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | 2ND FLOOR - WINDOW SCREENS - TORN | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | DIRT, TRASH, GARBAGE THROUGHOUT REAR YARD, BASEMENT AREAWAY, AND REAR PORCH. UNSANITARY CONDITIONS. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | EAST, SOUTH, WEST ELEVATIONS - WEEDS | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT - WINDOW - BOARDED (AT REAR) | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. (COVID-19 PANDEMIC) | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST - HANDRAIL FROM GRADE TO BASEMENT INSTALLED BACKWARDS;WEST - FRONT CONCRETE STAIRS - WASHED OUT MORTAR; PAINT PEELING | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 2X8 JOISTS SPAN APPROX. 11'-6"; BEAMS TOENAILED TO COLUMNS AT 2ND FLOOR; LOOSE, CUPPING RAIL AT 2ND FLOOR; TREADS CUPPING, SPLITTING FROM GRADE TO 1ST FLOOR; DIRT, TRASH THROUGHOUT STAIRS AND DECK. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | THRU-CORRIDOR - GUARDRAIL - LEANING | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EAST, SOUTH ELEVATIONS - TRASH, DEBRIS, GARBAGE AT REAR AND BASEMENT AREAWAY | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR SECURITY DOOR/2ND FLOOR - DOOR KNOB MISSING | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - SPALLING BRICKS. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH PARAPET SPALLING BRICKS. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | REAR PORCH - MISSING GUTTER AND DOWNSPOUT. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | EAST BASEMENT AREAWAY - MISSING FLOOR DRAIN. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | REAR YARD - LARGE HOLE NEXT TO PORCH. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | WEST CORNICE - WASHED OUT MORTAR. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST BASEMENT AREAWAY - CONCRETE HAS A LARGE HOLE. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | FRONT AND REAR YARDS - HIGH WEEDS AND GRASS. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH EXTERIOR STAIRS, GRADE TO BASEMENT - ERODED CONCRETE, MISSING HANDRAILS. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY PORCH: NORTH COLUMN EREDTED ON TOP OF CONCRETE BLOCK, FOOTING STATUS UNKNOWN.; UNDERSIZED 6"X6" BEAMS SPAN 6'-6".; UNDERSIZED 2"X8" DECK JOISTS SPAN 11'-5-1/2".; GUARDRAILS OVER 4'-0" LONG ARE MISSING INTERMEDIATE SUPPORT.; TREADS ARE SPLIT AND ONLY 9-1/4".; PORCH LUMBER COVERED WITH GREEN SUBSTANCE, CAUSING WOOD ROT.;DECK BOARDS ARE ROTTED ON EAST SIDE. PLANS AND PERMIT REQUIRED TO REPAIR OR REPLACE PORCH. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH EXTERIOR WALL MORTAR MISSING,WEST WALL VERTICAL JOINTS | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH ROOF ROTTED. | 6417 S EBERHART AVE | COMPLAINT | FAILED | View |