The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION,2ND FLOOR BROKEN PANE. | 311 W 47TH ST | COMPLAINT | FAILED | View |
RATS-ELEVATE MATERIAL 18" | REAR YARD,LUMBER STORED ON GROUND. | 311 W 47TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | BUILDING NORTH ELEVATION,2ND FLOOR,MISSING STONE VENEER. | 311 W 47TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT UNIT LIVING ROOM CEILING,LOOSE AND HANGING DRYWALL. | 311 W 47TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 311 W 47TH ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | OBTAIN PERMIT TO REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 311 W 47TH ST | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT DWELLING UNIT CEILING HEIGHT IS 6 FOOT 6 INCHES. | 311 W 47TH ST | COMPLAINT | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | BASEMENT DWELLING UNIT SPACE HEATER FLUE PIPE NOT CONNECTED. | 311 W 47TH ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT REAR FURNACE AREA,JUNK AND REFUSE ACCUMALATING. | 311 W 47TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT UNIT,MISSING SMOKE DETECTOR. | 311 W 47TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT UNIT,MISSING CARBON DETECTOR. | 311 W 47TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR PORCH,GRADE TO 2ND FLOOR,6 BY 6 COLUMNS SET ON DETERIORATING CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN,JOISTS ARE 2 BY 6 AND SPAN 9-FEET 8-INCHES,BEAM AND COLUMN CONNECTIONS PULLING APART AT FIRE CUTS,BEAMS SHOWING SIGNS OF ROTTING,COLUMNS ARE ROTTED AND OVER NOTCHED,RAILS ARE 33 INCHES HIGH,ROTTED,LOOSE AND PULLING,STRINGER ROTTED AND FACE NAILED AT TOP CONNECTION,TREADS ARE SPLITTING,DECKING BOARDS ARE ROTTED WITH HOLES.PLANS AND PERMIT REQUIRED. | 311 W 47TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION,FRONT STAIRS GRADE TO 1ST FLOOR,SPALLING CONCRETE SIDE WALLS. | 311 W 47TH ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE-MISSING SIDING,LEANING OUT OF PLUMB. | 311 W 47TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | ELECTRICAL POWER SERVICE DROP WITHIN REACH OF TENANTS / VISITORS. | 311 W 47TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO 1ST ,2ND AND ATTIC TO CHECK OCCUPANCY,DETECTORS. | 311 W 47TH ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT UNIT,WALLS THRU-OUT,MILDEW STAINS. | 311 W 47TH ST | COMPLAINT | FAILED | View |