Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEMO DEBRIS | 1946 REAR DEBRIS: BRICKS AND LIMESTONE. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY REAR LOOSE FLASHING, MISSING MORTAR. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST AND NORTH EXTERIOR WALL ABOVE 3RD FLOOR WINDOWS-LOOSE AND SHIFTED BRICK. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | EAST AND NORTH LINTELS-FALLING | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1946 FRONT STAIRS GRADE TO 1ST FLOOR-HANDRAIL MISSING. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 3403-1 FRONT-EXIT SIGN NOT ILLUMINATED. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S I.D. SIGN MISSING. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT, 2ND AND 3RD FLOOR-NO RESPONSE-UNVERIFIED DETECTORS. UNABLE TO INSPECT FRONT STAIRWAYS. UNABLE TO INSPECT REAR PORCHES. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
DEMO DEBRIS | 1946 REAR DEBRIS: BRICKS | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY REAR LOOSE FLASHING, MISSING MORTAR. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST AND NORTH EXTERIOR WALL ABOVE 3RD FLOOR WINDOWS;BRICKS BUCKLING OUT [PERMIT TO RESET BRICKS] | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | EAST AND NORTH LINTELS;SAGGING | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1946 FRONT STAIRS GRADE TO 1ST FLOOR-HANDRAIL MISSING.[NO ENTRY TO INTERIOR 11-30-10] | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 3403-1 FRONT-EXIT SIGN NOT ILLUMINATED.[NO ENTRY TO INTERIOR 11-30-10] | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S I.D. SIGN MISSING.[INSUFFICIENT INFORMATION] | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT, 2ND AND 3RD FLOOR-NO RESPONSE-UNVERIFIED DETECTORS. UNABLE TO INSPECT FRONT STAIRWAYS. UNABLE TO INSPECT REAR PORCHES.[ NO ENTRY TO INTERIOR NO RESPONSE FROM TENANTS 11-30-10] | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
PARAPET | NORTH-WEST CORNER PARAPET WALL;BRICKS MISSING AND LOOSE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS;OPEN JOINTS | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EAST EXTERIOR DOOR FRAME;ROTTED | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALKS;BROKEN CONCRETE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | NORTH ELEVATION STORE FRONT PLATE GLASS;BROKEN | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
DEMO DEBRIS | REAR - DEMOLITION DEBRIS | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR - ABANDONED VEHICLE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | 1ST-3401 & 1ST-1948 STORES - VACANT & SECURE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
DEMO DEBRIS | 1946 REAR DEBRIS: BRICKS | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY REAR LOOSE FLASHING, MISSING MORTAR. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION 3RD FLOOR WALL SECTION BETWEEN WINDOWS, BRICKS ARE SHIFTING OUTWARD.MASONRY PERMIT REQUIRED TO REPAIR EXTERIOR WALL. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 1948N./ 1ST NORTH ( NON RESIDENTIAL), EXIT SIGNS - NOT ILLIMINATED. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S I.D. SIGN MISSING.[INSUFFICIENT INFORMATION] | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT AND MOST DWELLING UNITS - NO ENTRY, NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS.NO ENTRY TO FRONT INTERIOR STAIRWAY AT 1946 N./. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THRU 2005 AND 2007 THRU 2010 | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
PARAPET | NORTH-WEST CORNER PARAPET WALL;BRICKS MISSING AND LOOSE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS;OPEN JOINTS | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EAST EXTERIOR DOOR FRAME;ROTTED | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALKS;BROKEN CONCRETE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | NORTH ELEVATION STORE FRONT PLATE GLASS;BROKEN | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING & REAR ENCLOSED PORCHES - NO ENTRY | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SIDE ENTRANCE DOOR TRANSOM - MISSING PANE | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - POST FULL MANAGEMENT SIGN | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | 1948 N./ - 1ST FLOOR NORTH ( NON RESIDENTIAL ) - MISSING FIRE EXTINGUISHER. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EAST EXTERIOR DOOR AT GRADE, LEADING TO INTERIOR STAIRWAYS - PEELING PAINT. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | INTERIOR STAIRWAY AT 1948 N./ STAIR SOFFIT 1ST TO 2ND - EXPOSED WOOD LATH. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 1948 N./ APT 1ST FLOOR, KITCHEN CEILING - PEELING PAINT. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | INTERIOR STAIRWAY AT 1948 N./ , 2ND FLOOR LIGHT FIXTURE - HANGING LOOSE. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 3403 W./ 1ST FLOOR - MISSING CARBON MONOXIDE DETECTOR. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH THREE STORY ENCLOSED PORCH, UNDERSIZED 6"X6" BEAMS SPAN 8'-7.BEAMS FASTENED TO COLUMNS WITH NAILS ONLY.UNDERSIZED 2"X8" DECK JOISTS SPAN 15'-4".GUARD RAILING SECTIONS ARE ONLY 36" HIGH.STINGERS ARE SCABBED.PORCH ENCLOSED WITH PLYWOOD ( NOT FIRE RATED).NORTH THREE STORY ENCLOSED PORCH, BEAMS ARE FASTENED TO COLUMNS WITH NAILS ONLY; MISSING SOUTH BEAMS AT 2ND AND 3RD FLOOR.3RD FLOOR DECK HEADER BEAM FASTENED TO RIM JOIST WITH NAILS ONLY.3RD FLOOR GUARD RAILING SECTION IS ONLY 37" HIGH, END POST TO WALL FASTENED WITH NAILS ONLY.GRADE TO 3RD STRINGERS ARE CRACKED AND FASTENED WITH NAILS ONLY.STAIR TREADS ARE LOOSE.PORCH ENCLOSED WITH PLYWOOD ( NOT FIRE RATED).PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH SYSTEMS (2). | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION 3RD FLOOR WALL SECTION BETWEEN WINDOWS, BRICKS ARE SHIFTING OUTWARD.MASONRY PERMIT REQUIRED TO REPAIR EXTERIOR WALL. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 3403 W./ 1ST FLOOR - MISSING CARBON MONOXIDE DETECTOR. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH THREE STORY ENCLOSED PORCH, UNDERSIZED 6"X6" BEAMS SPAN 8'-7.BEAMS FASTENED TO COLUMNS WITH NAILS ONLY.UNDERSIZED 2"X8" DECK JOISTS SPAN 15'-4".GUARD RAILING SECTIONS ARE ONLY 36" HIGH.STINGERS ARE SCABBED.PORCH ENCLOSED WITH PLYWOOD ( NOT FIRE RATED).NORTH THREE STORY ENCLOSED PORCH, BEAMS ARE FASTENED TO COLUMNS WITH NAILS ONLY; MISSING SOUTH BEAMS AT 2ND AND 3RD FLOOR.3RD FLOOR DECK HEADER BEAM FASTENED TO RIM JOIST WITH NAILS ONLY.3RD FLOOR GUARD RAILING SECTION IS ONLY 37" HIGH, END POST TO WALL FASTENED WITH NAILS ONLY.GRADE TO 3RD STRINGERS ARE CRACKED AND FASTENED WITH NAILS ONLY.STAIR TREADS ARE LOOSE.PORCH ENCLOSED WITH PLYWOOD ( NOT FIRE RATED).PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH SYSTEMS (2). | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 1948 N./ , 1ST FLOOR APT., BATHROOM DOOR - MISSING DOORKNOB. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION/3401-3RD FLOOR WALL SECTION BETWEEN WINDOWS.BULGING MASONARY OVER PUBLIC SIDEWALK,(DANGEROUS CONDITION).MASONARY PERMIT REQUIRED TO REPAIR EXTERIOR WALL. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE,UNVERIFIED DETECTORS,NO ENTRY TO VERIFY COMPLAINT OF 1948-RODENTS,FECES IN SHOWER,NO HEAT.NO ENTRY TO REAR ENCLOSED PORCHES. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2007 THRU 2008. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THRU 2005 AND 2007 THRU 2010 | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT AND MOST DWELLING UNITS - NO ENTRY, NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS.NO ENTRY TO FRONT INTERIOR STAIRWAY AT 1946 N./. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
PROTECT SIDEWALK DURING CONST | INSTALL PROTECTIVE CANOPY OVER NORTH ELEVATION.PUBLIC SIDWALK.WITH CANOPY.PERMIT ISSUED BY DEPARTMENT OF TRANSPORTATION REQUIRED FOR SUCH INSTALLATION. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 1948-N,3303-W,(NON-RESIDENTIAL)EXIT SIGNS-NOT ILLUMINATED. | 3401 W ARMITAGE AVE | PERIODIC | FAILED | View |