Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE SERVICE | REMOVE EMT IN SERVICE RUN FROM THE LOAD SIDE OF METER 14E-2-230.43 | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF EXISTING 1.5 STORY MASONRY HOUSE INCLUDING BUT NOT LIMITED TO:FULL REHAB OF BASEMENT, FIRST FLOOR AND ATTIC.BUILT NEW PARTITIONS.REPLACED SUPPORT BEAM IN BASEMENT WITH NEW LAMINATED BEAM. | 1811 N HARDING AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | NO PERMIT FOR ELECTRICAL WORK. NEW SERVICE INSTALLED, NEW DEVICES AND FIXTURES THROUGH OUT, NEW EQUIPMENT AND APPLIANCES | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | ADD LIGHT AT REAR BASEMENT DOOR | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
SUPPLEMENTAL GROUND | REPAIR BROKEN SUPPLEMENTAL GROUND | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | LABEL ALL CIRCUITS IN SERVICE PANEL | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD OUTLETS TO COMPLY WITH THE 6 FOOT 12 FOOT RULE FOR REQUIRED RECEPTACLES ON WALL SPACING 14E-2-210.52 | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | INSTALL MOGUL TYPE LB FOR SERVICE RUN 14E-3-314.16B | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
APPLIANCE INSIGHT DISCONNECT | PROVIDE DISCONNECT FOR DISHWASHER | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | ADD LIGHTS TO ALL BEDROOM CLOSETS 14E-2-210.52(2)(5) | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | FOR REMODELING WORK OF ELECTRICAL PIPE, WIRING SERVICE AND DEVICES | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT FOR FULL REHAB OF A SINGLE FAMILY HOME, INCLUDING BUT NOT LIMITED TO:ALL FLOORS FRAMING.DRYWALL AND ASSOCIATED MECHANICALS.TWO CAR WOOD FRAME GARAGE.ALL MASONRY WORK. | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | REAR ENCLOSURE AND AREAWAY AT EAST ELEVATION WATER SEEPAGE.13-196-520 RESIDENTIAL BUILDINGS THE FLOORS AND WALLS SHALL BE IMPERVIOUS TO LEAKAGE OF UNDERGROUND AND SURFACE RUNOFF WATER AND SHALL BE PROTECTED AGAINST DAMPNESS.13-196-530 THE FOUNDATION, EXTERIOR WALLS, AND EXTERIOR ROOF SHALL BE SUBSTANTIALLY WATERTIGHT AND PROTECTED, AND SHALL BE KEPT IN SOUND CONDITION AND REPAIR: | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7034) 18-28-604 INSULATION # 2 ALL SUPPLY & RETURN AIR DUCTS & PLENUMS SHALL BE INSULATION WITH A MINIMUM OF R-5 INSULATION WHEN LOCATED IN UNCONDITIONED SPACES | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
GIVE VENT OPENINGS % FL. AREA | 18-28-403.3 VENTILATION REQUIREMENT PROVIDE MECHANICAL EXHAUST AT CUBIC FEET PER MINUTE EQUAL TO SQUARE FEET OF FLOOR AREA TIMES FACTOR BASED ON USE NEED EXHAUST FANS FOR BASEMENT WASHROOM | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | 13-172-060 LIGHT & VENTILATION REQUIREMENT FOR OCCUPIED SPACES NEED NATURAL LIGHT FOR BASEMENT FAMILY ROOM & 2ND FLOOR MID BEDROOM | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7021) 18-28-603.5.1 FLEXIBLE AIR DUCTS # 3 NON METALLIC FLEXIBLE AIR DUCTS SHALL NOT BE ALLOWED IN RESIDENTIAL OCCUPANCIES NEEDS TO REMOVE PLASTIC FLEX FOR DRYER | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7038) 18-28-602 JOIST SPACE PLENUMS USED AS RETURNS FOR SINGLE FAMILY RESIDENCES #6 STUD WALL CAVITIES & JOIST SPACE PLENUM SHALL BE ISOLATED FROM ADJACENT CONCEALED SPACES BY APPROVED FIRE BLOCKING NEED TO PROPERLY SEAL JOIST SPACE RETURN AS PER CODE | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | REAR ENCLOSURE AND AREAWAY AT EAST ELEVATION WATER SEEPAGE.13-196-520 RESIDENTIAL BUILDINGS THE FLOORS AND WALLS SHALL BE IMPERVIOUS TO LEAKAGE OF UNDERGROUND AND SURFACE RUNOFF WATER AND SHOULD BE PROTECTED AGAINST DAMPNESS.13-196-530 THE FOUNDATION, EXTERIOR WALLS, AND EXTERIOR ROOF SHALL BE SUBSTANTIALLY WATERTIGHT AND PROTECTED, AND SHALL BE KEPT IN SOUND CONDITION AND REPAIR: | 1811 N HARDING AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT FOR FULL REHAB OF A SINGLE FAMILY HOME, INCLUDING BUT NOT LIMITED TO:ALL FLOOR FRAMING.DRYWALL AND ASSOCIATED MECHANICALS.TWO CAR WOOD FRAME GARAGE.ALL MASONRY WORK. | 1811 N HARDING AVE | COMPLAINT | PASSED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 1811 N HARDING AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE ARC FAULT CTIRCUIT INTERUPTER BREAKERS TO ALL BEDROOM CIRCUITS. 14E-2-210.12 | 1811 N HARDING AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE ACCESS FOR ROUGH INSPECTION 13-12-380 | 1811 N HARDING AVE | COMPLAINT | FAILED | View |