The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE | PROVIDE THERMOSTATIC MINING VALUES ON ALL CHILDREN SINKS. 18-29-607-1-1. | 6420 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
REPAIR COPING | EAST ELEVATION COPING STONES HAVE WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | GAINED ENTRY TO DAY CARE CENTER AND 6420 COMMON HALLWAY BUT UNABLE TO GAIN ENTRY TO 6422 HALLWAY AND APARTMENTS TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2016 ANNUAL INSPECTION. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | 6420 2ND FLOOR HALLWAY FIRE EXTINGUISHERS ARE DATED 2010 AND DAYCARE IS CENTER IS DATED 2014. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | EAST ELEVATION STONE CORNICE HAS WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | 6420 2ND FLOOR HALLWAY FIRE EXTINGUISHERS ARE DATED 2010 AND DAYCARE IS CENTER IS DATED 2014. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 1ST FLOOR NEAR FRONT DOOR EXIT SIGN OUT OF SERVICE. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | EAST ELEVATION STONE CORNICE HAS WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 1ST FLOOR NEAR FRONT DOOR EXIT SIGN OUT OF SERVICE. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION 6422 COMMON ENTRY DOOR DON'T SHUT OR LOCK. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 3RD FLOOR SMOKE DETECTOR MISSING AT CEILING. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2013 THRU 2016. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION 6422 COMMON ENTRY DOOR DON'T SHUT OR LOCK. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION NEAR TOP MASONRY WALL HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR COPING | EAST ELEVATION COPING STONES HAVE WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION STONE SILLS HAVE WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
CUT OR REMOVE HIGH WEEDS | WEST ELEVATION OVERGROWN WEEDS AND GRASS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION STONE SILLS HAVE WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | GAINED ENTRY TO DAY CARE CENTER AND 6420 COMMON HALLWAY BUT UNABLE TO GAIN ENTRY TO 6422 HALLWAY AND APARTMENTS TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2016 ANNUAL INSPECTION. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2013 THRU 2016. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION 3 STORY WOOD PORCH.6X6 COLUMNS ARE OVERNOTCHED,PULLING AWAY AT BEAM TO COLUMN CONNECTIONS AND ERECTED ON TOP OF CONCRETE SLABS.STATUS OF FOUNDATIONS UNKNOWN.GUARDRAILS HAVE MISSING PICKETS,TOENAILED TO COLUMNS AND WEAK AND UNSTABLE.2X8 JOIST SPANNING 10FT.STRINGERS FASTENED WITH COMMON NAILS.DECK BOARDS AND TREADS ARE BUCKLED.SOME SCABBING AT ROOF TOP BEAM TO COLUMNS.PLAN AND PERMIT REQUIRED TO REPLACE. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION NEAR TOP MASONRY WALL HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 3RD FLOOR SMOKE DETECTOR MISSING AT CEILING. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
CHIMNEY | THE CHIMNEY HAS SEVERELY ERODED BRICK MORTAR. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR PORCH ... 3 LEVELS. ALL NAILED JOINT CONECTED BANISTER COMPONENTS HAVE FAILED TO SUCH A DEGREE THE THESE WOOD MEMBERS ARE PULLING APART. THERE ARE NO METAL TIE BACK CLIPS AT ANY OF THESE BANISTER JOINTS.THERE ARE NO HEAVY DUTY BRACKETS AT ANY OF THE VITAL BEAM TO COLUMN JOINT CONECTIONS. THERE IS JOINT SEPARATION BETWEEN THESE STRUCTURAL BEAMS AND COLUMNS. THE COLUMNS ARE ALL OVER NOTCH CUT. THE LOUNGE AND GROOVE FLOOR DECK BOARDS, THAT ARE NOT DESIGNED FOR EXTERIOR USE, ARE SEVERELY DRY ROTTED AND BUCKLING. THE STAIR TREADS ARE LOOSE AND DRY ROTTED. THE ENTIRE STAIR SYSTEM, A SEPARATE STRUCTURE AFFIXED TO THIS PORCH, IS LATERALLY UNSTABLE AND SWINGS SEVERELY FROM SIDE TO SIDE. THE BEAMS SUPPORTING THIS STAIR SYSTEM ARE UNDERSIZED 2"X8" BOARDS. THIS PORCH IS IN A SEVERE STATE OF DISREPAIUR AND DANGEROUS AND HAZARDOUS. TEAR DOWN AND REPLACE WITH NEW ... PLANS AND PERMIT REQUIRED. | 6420 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |