The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SERVICE WALK, PASSAGE, AREAWAY | CEMENT CRACKED AT ALLEY BEHIND GARAGE | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT SIGN | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING 2007 | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
PARAPET & COPING | AT NORTH ELEVATION MORTAR EROSION BELOW COPING | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | GARAGE WITH GRAFFITI | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
1-HR STAIR ENCLOSURE, HOTEL | WEST PORCH ENCLOSURE(WOOD) IS NO 1-HOUR FIRE RATED | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | WEST PORCH MISSING JOIST HANGERS; STRINGERS ARE NOT BOLTED TO COLUMNS NOR TO WALLS; GUARD RAILS ARE AT 42" HIGH. OBTAIN PORCH REPAIR PERMIT TO CORRECT PORCH DEFICIENCIES. NO PLANS REQUIRED | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FRONT FOUNDATION STONES BELOW BASEMENT WINDOWS SPALLED, DETERIORATED, WASHED OUT MORTAR | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | EAST AND WEST GUTTERS/DOWNSPOUTS RUSTED FLAKING PAINT | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST STAIRS ROTTED STRINGERS AT GRADE | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | EAST AND WEST PORCHES REQUIRE 5/8 DRYWALL ON WALLS CEILINGS AND STAIR SOFFITS | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION PORCH, - 6X6 COLUMN SPLICE IS LESS THEN 18" WITH TWO BOLTS ONLY, - COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES: FOUNDATION STATUS UNKNOWN, - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS - PICKETS ARE ON EXTERIOR SIDE OF THE GUARDRAIL, - MISSING BRACKETS THROUGHT ENTIRE PORCH, - INCOMPLETE INSPECTION DONE FROM ALLEY, - UNABLE TO INSPECT EAST SECOND PORCH, - IRON GATE LOCK, - PERMIT TO REPAIR PORCH SYSTEM | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS OCCUPANCY AND CONDITIONS.UNABLE TO GAIN ENTRY, FRONT AND REAR SECURITY DOOR, UNABLE TO PERFORM 2016 ANNUAL INSPECTION. INCOMPLETE PORCH INSPECTION, DONE FROM PARKING LOT, UNABLE TO INSPECT SECOND PORCH FROM ALLEY. | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | EAST AT GRADE LOOSE TANGLED CABLE LINES | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO INTERIOR INSPECTION,UNABLE TO VIEW PORCH | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ACCESS TO EAST ENCLOSED PORCH | 3438 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | NORTH LIMESTONE SILL JOINTS OPEN WASHED OUT MORTAR | 3438 W FOSTER AVE | PERIODIC | FAILED | View |