Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FLAKY INTERIOR PAINT | LOOSE & FLAKING PAINT AT ALL WINDOW FRAMES, SASHES, AND MULLIONS AND REAR PORCH | 8405 S THROOP ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | DEBRIS & HIGH WEEDS AT REAR YARD & UNDER PORCH | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR FENCE AT ALLEY MISSING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH FROM GRADE TO 2ND FLOOR: SEVERELY ROTTED BEAM & COLUMN, LOOSE HANDRAILS, ROTTED FLOOR JOISTS, CUPPED DECKING, LOOSE TREADS, MISSING PICKETS, SUNKEN & OUT OF LEVEL TREADS, UNEVEN TREAD HEIGHTS & WIDTHS-DANGEROUS & HAZARDOUS (POSTED) | 8405 S THROOP ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | LOW HOT WATER PRESSURE AT 2ND FLOOR BATHTUB | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | NO WATER AT BATHROOM SINK, 2ND FLOOR | 8405 S THROOP ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | INOPERATIVE LIGHT FIXTURE AT 2ND FLOOR BATHROOM | 8405 S THROOP ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | OUTLETS INOPERATIVE AT 2ND FLOOR REAR BEDROOM | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WATER DAMAGE AT KITCHEN CEILING, 2ND FLOOR | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPL DEFECTIVE BATHROOM FLOOR | KITCHEN FLOOR TILES MISSING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER INFORMATION NOT POSTED | 8405 S THROOP ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD - JUNK AND TRASH. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS OPEN JOINTS. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
FLAKY INTERIOR PAINT | ALL EXT WOOD TRIMS - LOOSE AND PEELING PAINT. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | EXT WALL IVY GROWING AND FRONT AND REAR ELEVATIONS - HIGH WEEDS. REAR ABANDONED AND AUTO. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
CHIMNEY | CHIMNEY - OPEN JOINTS. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
REPAIR FENCE | NORTH FENCE - TORN AND BROKEN. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK AND PARKING PAVEMENT CRACKED AND BROKEN CONCRETE. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR EXTERIOR PORCH - ROTTED COLUMNS LOOKOUTS STRINGERS, RISER TREADS FLOOR JOISTS RAILS MISSING BOLTS ON LEDGERS BEAMS COLUMNS NO METAL HANGERS ON FLOOR JOIST NO FOOTINGS. OBTAIN PERMIT FOR ALL REPAIRS. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | FRONT MANAGEMENT SIGN NOT POSTED. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
SUBMIT FOR APPROVAL PLANS | 8405 S THROOP ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 8405 S THROOP ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 8405 S THROOP ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 8405 S THROOP ST | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | 8405 S THROOP ST | COMPLAINT | CLOSED | View | |
SAFE WORKING CONDITIONS | 2ND FLOOR INDIVIDUAL FURNACE WITH HOLES IN VENT AND GAPS IN METAL VENT PIPES AT CEILING. ALSO BATHROOM ACCESS DOOR TO FURNACE NOT B - TYPE FIRE RATED DOOR. BASEMENT WATER HEATER VENT PIPES EXIT THROUGH PLYWOOD BOARDED OVER WINDOW WITH NO PIPE CLEARANCE AT WOOD [HOT ] AND VENT PIPE ONLY EXTENDS UP 8' FROM GRADE. VENT PIPE EXHAUST AND CARBON MONOXIDE GASES EXIT AT 1ST FLOOR WINDOW - CREATING A HAZARDOUS CONDITION. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY AT 2ND - SMOKE DETECTOR - MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR APARTMENT - KITCHEN ONLY 66F. REAR EXIT DOOR AT KITCHEN - VERY DRAFTY WITH COLD AIR LEAKING IN AROUND DOOR AND JAMB - WEATHER STRIPPING MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT SMOKE DETECTOR OUT OF SERVICE. DETECTOR IS BROKEN OR HAS A LOW BATTERY. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT CARBON MONOXIDE DETECTOR - OUT OF SERVICE . DETECTOR IS BROKEN OR BATTERY IS LOW. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | EAST DOWNSPOUT - GRADE TO 1ST - SECTION MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AT 2ND - SMOKE DETECTOR - MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH BASEMENT AND EAST AT1ST AND 2ND BY PORCH - WINDOWS BOARDED OVER. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | REAR AT GRADE - CATCH BASIN - COVER MISSING . USING LOOSE PIECE OF PLYWOOD AS COVER. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
CHIMNEY HEIGHT | NORTH FLUE PIPE PROTRUDING FROM BASEMENT BOARDED OVER PLYWOOD WINDOW TO 1ST FLOOR WINDOW - CARBON MONOXIDEPOISONING AND FIRE HAZARDS [ FLUE PIPE ENDS ONLY 8' ABOVE GRADE - 2 STORY BUILDING IS 20' TO 25' HIGH ] . | 8405 S THROOP ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST BASEMENT STAIRWAY - GRADE TO BASEMENT AT GRADE - GUARDRAIL - MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE BLOCKS - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED OR SCREWED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM AND HEADER JOISTS. STRINGERS ONLY NAILED TO COLUMNS , HEADER JOISTS , AND MASONARY. 4 X 4 COLUMN LAP SPLICE ONLY NAILED AND ONLY 6'' LONG . 2 COLUMN SPLICES ONLY 3 ' APART. 6 X 6 COLUMN SCABBED WITH 1 X 6 WOOD PIECE NAILED ALONG 1 SIDE. ROOF BEAMS ONLY NAILED TO COLUMNS. STAIRWAY FROM 1ST TO 2ND LEVELS ONLY 28'' WIDE. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - APARTMENTS AND BASEMENT - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT BASEMENT INTERIOR STAIRWAY. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | RECENTLY BUILT REAR PORCH. PLANS AND PERMIT NOT AVAILABLE FOR REVIEW AT TIME OF INSPECTION. PERMIT #100438474, ISSUED 5/17/2012 NEVER FINALIZED. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY - MINOR HOME ALONE. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR CORNICE | SOUTH CORNICE - WASHED OUT MORTAR. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH AND WEST WINDOW SILLS - WASHED OUT MORTAR. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION STEP CRACK. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | GAPS, OPENINGS AT FOUNDATION ALLOWING RATS TO ENTER BUILDING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | TIRES, ETC. UNDERNEATH REAR PORCH | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT - WINDOW - CRACKED PANE | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - STEP FRACTURES | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION - GAPS, CREVICES AT REAR ENCLOSURE | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS - WASHED OUT MORTAR | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | WEST, EAST ELEVATIONS - STORM DOORS MISSING AT FRONT AND REAR ENTRANCES | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | GUTTER, DOWNSPOUT - RUSTING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | NORTH, EAST ELEVATIONS - TRASH, DEBRIS, LEAVES ON SIDE OF BUILDING, REAR YARD, AND BASEMENT AREAWAY | 8405 S THROOP ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 2ND FLOOR KITCHEN CEILING BUCKELED/LOOSE PLASTER. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
REPAIR GUTTER | REAR ELEVATION GUTTER RUSTED/LEAKING. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
REPAIR ROOF | ROOF LEAKING 2ND FLOOR KITCHEN. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
MICE/RODENTS | 2ND FLOOR APT. MICE. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
ROACHES | 2ND FLOOR APT. ROACHES. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
REPAIR SCREENS | ALL ELEVATIONS MISSING/BROKEN SCREENS. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR APT. DEFECTIVE SMOKE DETECTOR. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR APT. DEFECTIVE CARBON MONOXIDE DETECTOR. | 8405 S THROOP ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS & PERMITS NEEDED FOR PORCH | 8405 S THROOP ST | COMPLAINT | FAILED | View |
POST OWNER NAME OF VACNT BLDG | 8405 S THROOP ST | COMPLAINT | CLOSED | View | |
SEE INSPECTOR COMMENTS | SEE DEFECT NOTICE # 12418 | 8405 S THROOP ST | PERMIT | FAILED | View |
REPUTTY WINDOW PANES | WINDOW TRIM - PAINT PEELING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION 2 STORY WOOD PORCH SYSTEM / TREADS - WEATHERED, CUPPING AND BOWING IN MULTIPLE LOCATIONS. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; BEAMS TOENAILED TO COLUMNS AT 2ND FLOOR; CRACKED WINDER FROM 1ST TO 2ND FLOOR | 8405 S THROOP ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH - GRILLS, TABLES, COOLER, ETC. ON PORCH DECKS OBSTRUCTING EXITWAYS | 8405 S THROOP ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | TRASH, DEBRIS THROUGHOUT REAR YARD | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - WASHED OUT MORTAR | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR GUTTER | GUTTER - RUSTING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, AND ENCLOSED AREA OF REAR PORCH. UNVERIFIED DETECTORS AND CONDITIONS. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | DOWNSPOUT - RUSTING; NOT EXTENDING TO GRADE; SECTION MISSING | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | BUILDING / SCREENS - DAMAGED OR MISSING IN MULTIPLE LOCATIONS. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NORTH ELEVATION / CHIMNEY CAP - MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION / EXTERIOR WALL - STEP CRACKS WITH WASHED OUT MORTAR IN VARIOUS LOCATIONS. SOUTH ELEVATION / EXTERIOR WALL - COVERED IN IVY. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - DENIED ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF INSECT AND RODENT INFESTATION. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | EAST ELEVATION / DOWNSPOUT - DISCONNECTED FROM GROUND. | 8405 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION / GATE -MISSING. | 8405 S THROOP ST | COMPLAINT | FAILED | View |