Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY CAPPING | CHIMNEY MISSING CAP. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PROVIDE GUTTER & DOWNSPOUT | NORTHEAST CORNER MISSING DOWNSPOUT. SOUTHEAST CORNER DISCONNECTED DOWNSPOUT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY LOOSE & MISSING MORTAR. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR FURNACE ROOM PLASTER CEILING COMING DOWN. DINING ROOM WALL HAS LOOSE PLASTER. EXPOSED LATH. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR UNIT MISSING CO DETECTOR. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS TO BRING REAR WOOD PORCH UP TO TODAY'S SAFETY CODE STANDARDS, CURRENT ATTEMPTED REPAIRS ARE SUBSTANDARD. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR WOOD FRAMED PORCH LOOKOUT PULLING AWAY FROM SUPPORT COLUMN. 6X6 ROTTED AT FOOTING, PICKET SPACING TOO FAR APART. PORCH IS DANGEROUS & HAZARDOUS. IMPROPERLY SCABBED & REPAIRED. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION WALL LOOSE AND MISSING MORTAR. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE. TRIP HAZARD. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES ON 1ST FLOOR. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO 2ND FLOOR FRONT DECK. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | PROVIDE PERMIT TO CORRECT VIOLATIONS. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE ROUGH INSPECTION FOR INSTALLATION OF NEW ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT 1ST, 2ND FLOOR UNITS AND ATTIC SPACE, PORCH AREAS. (13-12-380) | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF NEW ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT 1ST, 2ND FLOOR UNITS, ATTIC SPACE AND PORCH AREAS WITHOUT PLANS OR PERMITS. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS AND GARAGE. (18-27-210.25) | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View | |
DEFECTIVE LIGHTING SERVICE | REPLACE DEFECTIVE CABLES IN SERVICE CONDUIT RISER, CABLES ARE TOO SHORT OUT OF SERVICE HEAD. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR INTERIOR AND EXTERIOR ALTERATIONS TO THIS BUILDING. ALTERATIONS INCLUDE BUT ARE NOT LIMITED TO: 1). INTERIOR DEMOLITION THAT INCLUDED REMOVAL OF FINISH AND SUBFLOORING, REMOVAL OF WOOD LATH AND PLASTER AND REMOVAL OF PARTITIONS AT FIRST AND SECOND FLOORS. 2). INSTALLATION OF NEW SUBFLOORING, NEW PARTITION FRAMING, NEW DRYWALL ON WALLS AND CEILINGS AT FIRST, SECOND AND THIRD FLOORS. ON THE FIRST FLOOR THERE IS A SINGLE DWELLING UNIT WITH A LIVING AREA, KITCHEN, BATHROOM, TWO BEDROOMS AND A UTILITY ROOM WITH FURNACE, ON THE SECOND FLOOR THERE IS A SECOND DWELLING UNIT WITH THE SAME ROOM CONFIGURATION AND AT THE ATTIC THERE IS A FINISHED ROOM AT THE FRONT WITH CLOSETS, A ROUGHED-IN BATHROOM AT THE CENTER AND A FINISHED ROOM AT THE REAR. 3). INSTALLATION OF NEW INTERIOR DOOR SYSTEMS ON FIRST, SECOND AND ATTIC LEVELS. 4). INSTALLATION OF NEW CABINETS IN KITCHEN ON FIRST AND SECOND FLOORS. 5). INSTALLATION OF NEW GAS FIRED, FORCED WARM AIR FURNACES WITH ELECTRICAL POWER SUPPLY, GAS SUPPLY PIPING AND DUCTWORK ON FIRST AND SECOND FLOORS. 6). INSTALLATION OF TWO CENTRAL AIR CONDITIONING CONDENSER UNITS AT SECOND FLOOR PORCH DECK. 7). REPAIR OF THREE LEVEL WOOD PORCH SYSTEM THAT INCLUDED REPLACEMENT OF STRUCTURAL MEMBERS. 8). NEW WINDOW AND DOOR SYSTEMS AT EXTERIOR. 9). NEW VINYL SIDING AT REAR ENCLOSED PORCH. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE ONE HOUR FIRE RESISTIVE ENCLOSURE AT REAR THREE LEVEL WOODEN PORCH ENCLOSURE. EXISTING CONDITION IS EXPOSED WOOD FRAMING AT INTERIOR SIDE AND WOOD SHEATHING COVERED WITH VINYL SIDING AT EXTERIOR. (13-200-260(2)) | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REPAIR WOODEN THREE LEVEL PORCH SYSTEM AT REAR OF BUILDING: 1). REPLACE CENTER SUPPORT BEAM AT SECOND FLOOR DECK. BEAM IS BADLY ROTTED AT CONNECTION TO COLUMN. 2). 38 INCH TALL BALUSTRADE ON SECOND FLOOR DECK IS LESS THAN 42 INCH MINIMUM REQUIREMENT. 3). BALUSTER SPACING VARIES FROM 5-3/8 INCHES TO 5-3/4 INCHES WHICH EXCEEDS MAXIMUM ALLOWED. 4). JOIST AT SOUTHEAST CORNER OF SECOND FLOOR DECK SPLICED AT MID SPAN. 5). DECKS AT SECOND FLOOR AND ATTIC LEVEL DO NOT PROVIDE 100 POUNDS PER SQUARE FOOT LIVE LOAD REQUIREMENT. 6). WOOD MEMBER SUPPORTING STAIR SYSTEM AND LANDING BETWEEN GROUND LEVEL AND SECOND FLOOR HAS PULLED AWAY FROM POCKET IN BRICK WALL. PORCH REPAIRS REQUIRES ARCHITECTURAL PLANS AND PERMIT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | REPAIR EXTERIOR WALLS AT: 1). ERODED MORTAR JOINTS AT EAST ELEVATION NEAR GROUND LEVEL. 2). AT SOUTH ELEVATION SEE GLASS BLOCK WINDOW INSTALLATION AT FIRST AND SECOND FLOORS. AMATEURISH WORKMANSHIP THAT INCLUDES WOOD BOARD INSTALLED FLAT WAYS AND PROJECTING BEYOND WALL SURFACE THAT APPEARS TO BE A MAKESHIFT LINTEL AND INCOMPLETE BRICK INFILL ABOVE WINDOW. 3). PROPERLY INFILL TWO ABANDONED WINDOW OPENINGS AT ATTIC LEVEL. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | REPAIR ROOF COVERING ABOVE REAR ENCLOSED PORCH. THE SHINGLES ARE INDULATING UP AND DOWN INSTEAD OF LAYING FLAT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | ATTIC STORAGE SPACE CONVERTED TO LIVING SPACE THAT INCLUDES A BEDROOM, A BATHROOM AND LIVING AREA. ON THE DATE OF INSPECTION THE WORK TO COMPLETE THIS AREA WAS NOT FINISHED AND APPEARS TO BE AN EFFORT TO INSTALL AN ADDITIONAL DWELLING UNIT. THE ATTIC SPACE DOES NOT PROVIDE REQUIRED NATURAL LIGHT AND VENTILATION AND THE SINGLE EXIT IS INSUFFICIENT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE PLBG FIXTURE | FIRST FLOOR BATHROOM - TUB SURFACE CHIPPED, REPAIR OR REPLACE UNIT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
INSTALL FIXTURES PROPER MATERL | FIRST FLOOR BATHROOM - TUB HAS PLUNGER STYLE WASTE AND OVERFLOW, REPLACE WITH AN APPROVED STYLE UNIT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
OPEN | FIRST FLOOR WATER HEATER - INSTALL A SAFE PAN AND PIPE TO AN OPEN SITE DRAIN. (18-29-504.8) | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PRV RELIEF VALVE HOTWATER HTR | FIRST FLOOR WATER HEATER - PIPE RELIEF VALVE TO OPEN SITE DRAIN. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
INSTALL FIXTURES PROPER MATERL | SECOND FLOOR BATHROOM - TUB HAS PLUNGER STYLE WASTE AND OVERFLOW, REPLACE WITH AN APPROVED STYLE UNIT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
PRV FLUE FOR HOT WATER HEATER | WATER HEATER FIRST FLOOR - RUN FLUE PIPE TO AN APPROVED CHIMNEY THROUGH ROOF. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
SUBMIT REVISED PLANS FOR PERMT | SUBMIT PLANS FOR REVIEW FOR COMPLETE REHAB OF TWO DWELLING UNITS AND ATTIC SPACE. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. | 1453 S KEDVALE AVE | COMPLAINT | PASSED | View |