The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REPLACE SMOKE DETECTORS | 2163 S MILLARD UNIT 2 - SMOKE DETECTOR - BEEPING. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 2163 S MILLARD UNIT 2 - REAR DOOR - LARGE GAP NEAR BOTTOM/OUT OF PLUMB. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - MASONRY WALL - SPALLING BRICKS AND CEMENT PARGE. SOUTHEAST CORNER MIDWAY UP WALL - VERTICAL FRACTURE AND SHIFTING.PERMIT REQUIRED FOR MASONRY REPAIRS. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
CHIMNEY | EAST ELEVATION - CHIMNEY - SPALLING BRICKS AND CEMENT PARGE. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | 3624 W CERMAK UNIT 1 - VINYL WINDOWS ON WEST SIDE OF APARTMENT ARE HARD TO OPEN/NOT LATCHING. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
REPAIR CORNICE | SOUTHWEST CORNER NEAR TOP - CORNICE - WASHED OUT MORTAR. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | 3624 W CERMAK UNIT 1 - SMOKE DETECTOR MISSING NEAR FRONT BEDROOM. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION - SILLS - WASHED OUT MORTAR. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 3624 W CERMAK - CARBON MONOXIDE DETECTOR - MISSING NEAR FRONT BEDROOM. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | GAINED ENTRY TO HALLWAY'S,PORCHES AND SOME APARTMENTS BUT NOT ALL TO VERIFY OCCUPANCY<DETECTORS AND OVERALL CONDITION.UNABLE TO GAIN ENTRY TO BASEMENT TO VERIFY COMPLAINT OF A FOUL ODOR. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED 2006-2008. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | NORTH ELEVATION-NEWLY BUILT REAR PORCH-PLANS, PERMIT NOT AVAILABLE FOR REVIEW AT TIME OF INSPECTION. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | BUILDING RESIDENCE & COMMERCIAL-DEADBOLT LOCKS MISSING AT FRONT AND REAR ENTRANCES. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 3624-BARBERSHOP- BURGLAR BARS ON REAR ENTRANCE; PADLOCKED DURING BUSINESS HOURS. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
NO POSTED ADDRESS | 3624-BARBERSHOP ADDRESS NOT POSTED | 3622 W CERMAK RD | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 3624-BARBERSHOP EXIT SIGNS ARE NOT ILLUMINATED | 3622 W CERMAK RD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED 2006-2010. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | NORTH ELEVATION-NEWLY BUILT REAR PORCH-PLANS, PERMIT NOT AVAILABLE FOR REVIEW AT TIME OF INSPECTION. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | BUILDING RESIDENCE & COMMERCIAL-DEADBOLT LOCKS MISSING AT FRONT AND REAR ENTRANCES. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
NO POSTED ADDRESS | SOUTH MILLARD- ADDRESS CURRENTLY POSTED ON BUILDING 2171-2177 IS DIFFERENT FROM THE ADDRESS ON FILE 2163 - 2165 | 3622 W CERMAK RD | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 3624-BARBERSHOP LOUVERED/VENTILATED DOOR MISSING AT FURNACE ROOM | 3622 W CERMAK RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNABLE TO INSPECT 3622, 2163 APARTMENTS-UNVERIFIED DETECTORS. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
ARRANGE FOR INSPECTION | CONTACT INSPECTOR #655 AT 312 743-3562 | 3622 W CERMAK RD | PERIODIC | FAILED | View |
ACCESS TO ROOF | 3622 W CERMAK RD | PERIODIC | FAILED | View | |
REPAIR PORCH SYSTEM | 2163-65 REAR PORCH ALL LEVELS GUARDRAILS SCREWED TO WALL, NOT BOLTED; BEAM AT ROOF LEVEL NOT CEMENTED INTO WALL POCKET;3622-24 REAR PORCH LEDGER BOARDS AT 2ND FLOOR AND ROOF LEVEL NOT BOLTED; GUARDRAILS AT ALL LEVELS NOT ATTACHED TO THE EXTERIOR WALL, LARGE GAP BETWEEN END POST AND WALL | 3622 W CERMAK RD | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST TO 3RD FLOOR - REAR DOORS WITHOUT VIEWING DEVICES | 3622 W CERMAK RD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED | 3622 W CERMAK RD | PERIODIC | FAILED | View |
NO POSTED ADDRESS | SOUTH MILLARD- ADDRESS CURRENTLY POSTED ON BUILDING 2171-2177 IS DIFFERENT FROM THE ADDRESS ON FILE 2163 - 2165 | 3622 W CERMAK RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | 2ND AND 3RD FLOOR: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. | 3622 W CERMAK RD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - NEW OWNER'S I.D. SIGN - MISSING | 3622 W CERMAK RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNABLE TO INSPECT 3622, 2163 APARTMENTS-UNVERIFIED DETECTORS. | 3622 W CERMAK RD | PERIODIC | FAILED | View |