Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 1:38 AM
PIN: 20184130050000
Property Address: 6011 S HERMITAGE AVE
City - Zip: CHICAGO - 60636
2023 Property Class: 202
2023 Township: 72 - Lake
2023 Neighborhood: 72120
2023 Tax District: 72163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 8 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR REAR GRADE TO 1ST FLOOR EXTERIOR STAIRWAY/ LEDGER BEAM - ONLY NAILED TO BUILDING'S EXTERIOR WALL. STRINGER - UPPER ENDS ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. STAIR RAILINGS - LADDER TYPE WITH APPROXIMATELY 8 TO 10 INCHES BETWEEN MEMBERS. PERMIT ONLY REQUIRED FOR REAR STAIRWAY REPAIRS. 6011 S HERMITAGE AVE COMPLAINT FAILED View
REPLACE D&H PORCH FRONT 1-STORY WOOD PORCH WITH ROOF/ 6X6 COLUMNS ARE ROTTED, TWISTED AND LEANING OUT OF PLUMB; DOUBLE NOTCHED FOR RIM JOISTS.LEDGER BEAM - ONLY NAILED TO BUILDING'S EXTERIOR WALL.RIM JOISTS ARE ONLY NAILED TO COLUMN NOTCH.UNDERSIZED 2X6 DECK SPAN APPROXIMATELY 12 FEET AND ARE ONLY NAILED TO RIM JOISTS.4X4 COLUMNS ARE RESTING ON CONCRETE BLOCKS, FOUNDATION STATUS IS UNKNOWN; LEANING OUT OF PLUMB.STRINGERS - UPPER END ARE INADEQUATELY SUPPORTED WITH NAILS ONLY.LANDING RIM AND DECK JOISTS ARE ROTTED AND ONLY NAILED; SLOPED AND UNSTABLE.ALL RAILING ARE LOOSE, PULLING AND ONLY NAILED TO COLUMNS AND POSTS; LADDER TYPE WITH APPROXIMATELY 6 TO 10 INCHES BETWEEN MEMBERS.GUARD RAILINGS - ONLY 36 INCHES HIGH.TREADS - LOOSE, ROTTED AND BROKEN THOUGHOUT.ROOF HEADER BEAM - ROTTED WITH PEELING PAINT.PLAN AND PERMIT REQUIRED TO REPLACE FRONT PORCH. 6011 S HERMITAGE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED. 6011 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR ROOF ENTIRE ROOF/ SHINGLES - MISSING SECTIONS AND DETERIORATED. 6011 S HERMITAGE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT ELEVATION/ ATTIC WINDOW - BROKEN PANE.SOUTH ELEVATION/ BASEMENT WINDOW NEAR EAST END - BROKEN PANE. 6011 S HERMITAGE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH FRONT, SOUTH AND REAR ELEVATIONS/ VARIOUS WINDOIW SAHSES - ROTTED WITH PEELING PAINT. 6011 S HERMITAGE AVE COMPLAINT FAILED View
MAINTAIN WINDOW FRONT, SOUTH AND REAR ELEVATIONS/ VARIOUS WINDOWS/ EXTERIOR TRIM - ROTTED WITH PEELING PAINT. 6011 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT AND SOUTH ELEVATIONS/ EXTERIOR WALL/ EXTERIOR SIDING - MISSING AND BROKEN SECTIONS. 6011 S HERMITAGE AVE COMPLAINT FAILED View