Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBSTRUCTIONS IN EXIT WAY | UNABLE TO USE REAR EXIT DUE TO PLACEMENT OF STOCK AND BAND SAW - DANGEROUS AND HAZARDOUS . | 457 E 79TH ST | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | UNTAGGED FIRE EXTINGUISHERS OBSERVED. | 457 E 79TH ST | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | WATER DAMAGED CEILING OBSERVED. | 457 E 79TH ST | COMPLAINT | PASSED | View |
REPAIR LINTELS | EAST ELEVATIONS LINTELS SAGGING. | 457 E 79TH ST | COMPLAINT | PASSED | View |
REPAIR FLOOR | MISSING FLOOR TILES. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE OPEN FRONT TOILET SEAT | RESTROOM SOUTHWEST ELEVATION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO LAVATORY, TOILET, RESTROOM HAND SINK AND TRIPLE COMPARTMENT SINK SOUTH ELEVATION. SINGLE COMPARTMENT SINK AND WATER HEATER SOUTHWEST ELEVATION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE | GREASE TRAP FOR THREE COMPARTMENT SINK TOO SMALL SOUTH ELEVATION. (18-29-1003.3.6) | 457 E 79TH ST | COMPLAINT | PASSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER TO LAVATORY HAND SINK, THREE COMPARTMENT SINK, SINGLE COMPARTMENT SINK. | 457 E 79TH ST | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON THREE COMPARTMENT SINK SOUTH ELEVATION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | THREE COMPARTMENT SINK LEAKS SOUTH ELEVATION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE | NO SAFE PAN UNDER WATER HEATER ABOVE THREE COMPARTMENT SINK SOUTH ELEVATION. (18-29-504.8) | 457 E 79TH ST | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | DISCHARGE PIPE MISSING ON RELIEF AT WATER HEATER ABOVE THREE COMPARTMENT SINK SOUTH ELEVATION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE VACUUM RELIEF ON WATER HEATER ABOVE THREE COMPARTMENT SINK SOUTH ELEVATION. (18-29-504.2) | 457 E 79TH ST | COMPLAINT | PASSED | View |
WORKING SPACE | REMOVE ALL DEBRIS FROM IN FRONT OF ELECTRICAL PANEL AT REAR INTERIOR AREA. | 457 E 79TH ST | COMPLAINT | PASSED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT ENTIRE STORE AREA - DANGEROUS AND HAZARDOUS CONDITION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR BARE WIRES BEHIND COOLERS, BETWEEN LIGHT FIXTURES AND BETWEEN JUNCTION BOXES THROUGHOUT STORE AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN SLOTS IN ELECTRICAL PANEL WITH EXPOSED LIVE PARTS AND JUNCTION BOXES MISSING KO FILLER THROUGHOUT STORE AREA - DANGEROUS AND HAZARDOUS CONDITION. | 457 E 79TH ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT IN REAR BATHROOM. | 457 E 79TH ST | COMPLAINT | PASSED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT, JUNCTION BOXES RUNS THROUGHOUT ENTIRE STORE AREA AND AT ALL EXTERIOR AREAS OF BUILDING. | 457 E 79TH ST | COMPLAINT | PASSED | View |
CORRODED CONDUIT & EQUIP | REPLACE ALL RUSTED, CORRODED CONDUIT, JUNCTION BOXES AT ALL EXTERIOR AREA OF BUILDING. | 457 E 79TH ST | COMPLAINT | PASSED | View |
APPLIANCE INSIGHT DISCONNECT | PROVIDE A DISCONNECT FOR ELECTRIC WATER HEATER AT REAR AREA OF STORE. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE WEATHERPROOF BOXES, FITTINGS AND APPROVED RACEWAYS FOR ALL EXTERIOR AREAS OF BUILDING. (18-27-110.11) | 457 E 79TH ST | COMPLAINT | PASSED | View | |
OBTAIN PERMIT BEFORE SIGN WORK | SIGN READS' WELCH'S, EBERHART FOOD FAITH DAIRY, ETC FLAT VINYL SIGN ON THE EAST NORTHEAST, NORTH ELEVATIONS APPROXIMATE, SIZE' 35'X 4' | 457 E 79TH ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT BEFORE SIGN WORK | SIGN READS' BAKERY, FROZEN, NACHOS, MEATS ETC INSIDE WINDOW APPROXIMATE, SIZE' 16'X 8 13-20-520 | 457 E 79TH ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSE PLUMBER FOR REPAIR WORK | 457 E 79TH ST | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVER FOR OPEN JUNCTION BOX WITH EXPOSE WIRING IN REAR STORE AREA AND OPEN SLOTS IN ELECTRICAL PANEL WITH EXPOSE LIVE PARTS DANGEROUS AND HAZARDOUS CONDITION | 457 E 79TH ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PERMIT FOR ALL PLUMBING WORK | 457 E 79TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN GLASS BLOCK WINDOWS EAST ELEVATIONS 14X-3-303.13 | 457 E 79TH ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHER AT REAR NOT TAGGED DANGEROUS AND HAZARDOUS 14X-5-504.5 | 457 E 79TH ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | RESTORE ALL EXIT SIGN AND EM LIGHTS TO WORKING CONDITION DANGEROUS AND HAZARDOUS CONDITION | 457 E 79TH ST | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE PROPER DISCONNECT FOR ELECTRIC WATER HEATER IN REAR OF BUILDING 18-29-504 | 457 E 79TH ST | COMPLAINT | FAILED | View |
WORKING SPACE | REMOVE ALL DEBRIS FROM ELECTRICAL PANEL AREAS | 457 E 79TH ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE AT COUNTERTOP AREA AND THROUGH OUT STORE AREAS DANGEROUS AND HAZARDOUS CONDITION | 457 E 79TH ST | COMPLAINT | FAILED | View |
PROVIDE | OPENING AT CASHIER 32" AND AISLES RESTRICTIONS WITH STOCK DANGEROUS AND HAZARDOUS 14B-10-1018.1 | 457 E 79TH ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | REMOVE UNAPPROVED 3/4" FLEXIBLE WATER SUPPLY LINE AT WATER HEATER IN REAR OF BUILDING AND HAND PIPE WITH APPROVED METAL WATER PIPING | 457 E 79TH ST | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 14A-4-404.6 | 457 E 79TH ST | COMPLAINT | FAILED | View | |
APPLIANCE INSIGHT DISCONNECT | PROVIDE DISCONNECT FOR ELECTRIC WATER HEATER | 457 E 79TH ST | COMPLAINT | FAILED | View |
REMOVE MINI-BREAKERS | REMOVE ALL MINI BREAKERS IN 3 PHASE PANEL DANGEROUS AND HAZARDOUS CONDITION | 457 E 79TH ST | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE MIXING VALVE FOR ALL HAND SINKS AT ALL LOCATIONS 18-29-607.1.1 | 457 E 79TH ST | COMPLAINT | FAILED | View |
HEAT FACTORY/WORKSHOP | FURNACE INSTALLED INCORRECT (RETURN AND VENTS AND NOT SEPARATED) MISSING COVER, VENTING UNKNOWN TEMP 60 DEGREES PROVIDE PLANS AND PERMIT 14X-8-802.3 FLUE PIPE FROM FURNACE NOT SEALED AT CHIMNEY | 457 E 79TH ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH REAR EXIT OF STORE SEALED WITH SPRAY FOAM SHUT SCIZZOR GATES DANGEROUS AND HAZARDOUS 14B-10-1004 | 457 E 79TH ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | LINTELS EAST RUSTED AND SAGGING PERMIT REQUIRED 14X-3-303.1.1 | 457 E 79TH ST | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | REPLACE DETERIORATED CONDUCTORS AT SERVICE HEAD | 457 E 79TH ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH REAR EXIT OF STORE EXIT BLOCKED WITH STORAGE INTERIOR DANGEROUS AND HAZARDOUS 14X5-505.1.2 | 457 E 79TH ST | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | PROVIDE OPEN FRONT SEAT AT TOILET AT ALL LOCATIONS | 457 E 79TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NON WORKING CARBON MONOXIDE DETECTOR DANGEROUS AND HAZARDOUS 14X-5-504.9 | 457 E 79TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL EAST STEP FRACTURES AT MORTAR JOINTS 14X-3-303.1.1 | 457 E 79TH ST | COMPLAINT | FAILED | View |
REMOVE | AISLE RESTRICTIONS THROUGHOUT DUE TO PLACEMENT OF STOCK AND SHELVING, CAUSING DANGEROUS CONDITIONS. (15-4-880) | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE AIR CHAMERS | NO AIR CHAMBERS TOILET, LAVATORY, HAND SINK, THREE COMPARTMENT SINK, SINGLE COMPARTMENT SINK. | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE SAFE PAN UNDER WATER HEATER SOUTHWEST ELEVATION. (18-29-504.8) | 457 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE FLOOR DRAIN FOR CONDENSATE AND HOT WATER HEATER SOUTHWEST ELEVATION. (18-29-412.4) | 457 E 79TH ST | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 457 E 79TH ST | COMPLAINT | PASSED | View |
ALL ELECTRICAL CONDUIT RUNS, JUNCTION BOXES AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER THROUGHOUT THE ENTIRE STORE. (18-27-110.12) | 457 E 79TH ST | COMPLAINT | PASSED | View | |
UNAPPROVED CORDS | REMOVE ALL UNAPPROVED CORDS THROUGHOUT ENTIRE STORE AREAS - DANGEROUS AND HAZARDOUS. | 457 E 79TH ST | COMPLAINT | PASSED | View |
ALL PANELS SHALL BE LEGIBLY LABELED WITH CORRESPONDING BREAKER IN PANEL. (18-27-384.13) | 457 E 79TH ST | COMPLAINT | PASSED | View | |
PROVIDE | PROVIDE FLOOR DRAIN FOR COOLER CONDENSATE WATER EAST ELEVATION. (18-29-412.4) | 457 E 79TH ST | COMPLAINT | PASSED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. (13-12-360) | 457 E 79TH ST | COMPLAINT | PASSED | View |