Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SMOKE & CARBON DETECTORS | BASEMENT | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | WATER DAMAGED LIGHT FIXTURE IN BASEMENT BATHROOM | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | BASEMENT BUILDOUT | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION/ EXTERIOR MASONRY WALL - WASHED OUT MORTAR.WEST ELEVATION/ VINYL SIDING - LOOSE AND BUCKLED WITH HOLES. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
CONNECT DOWNSPOUT TO SEWER | SOUTH AND REAR ELEVATIONS/ DOWNSPOUTS - NOT CONNECTED TO SEWER. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION/ STONE SILLS - WASHED OUT MORTAR AND SHIFTING STONES. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | SOUTH ELEVATION/ BASEMENT WINDOWS - MISSING CASING AROUND WINDOWS. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | WINDING STAIRCASE FROM BASEMENT TO 1ST FLOOR. TREADS ONLY 8" WIDE. RISER HEIGHTS NOT UNIFORM, VARY FROM 6.25" TO 11.25". | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT AND 1ST FLOOR APARTMENT/ SMOKE DETECTORS - MISSING | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 1ST FLOOR APARTMENT/ CARBON MONOXIDE DETECTORS - MISSING. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT/ CEILING - HEIGHT ONLY 6' 1" | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
POULTRY-UNSANITARY CONDITIONS | REAR ENCLOSED PORCH/ 2ND FLOOR DECK - CHICKEN COOP WITH ROOSTER IN IT. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT SPACE FINISHED WITHOUT A PERMIT AND DUPLEXED INTO 1ST FLOOR APARTMENT. NO PERMIT OBTAINED. PLANS AND PERMIT FOR 1ST FLOOR TO BASEMENT DUPLEX ARE NOW REQUIRED. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | BASEMENT SPACE FINISHED WITHOUT A PERMIT AND DUPLEXED INTO 1ST FLOOR APARTMENT. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 2-STORY ENCLOSED PORCH - UNDERSIZED 2X8 JOISTS SPAN 10'. STAIR RISER HEIGHTS VARY FROM 4.5" TO 8.25". RAILINGS ONLY 30" HIGH. ALSO LOOSE AND PULLING. ENTIRE PORCH LEANING AWAY FROM BUILDING.PLANS AND PERMIT REQUIRED TO REPAIR REAR ENCLOSED PORCH. | 344 S KOSTNER AVE | COMPLAINT | PASSED | View |