Chicago Building Violations Data: 15 Violations
Violation Inspector Comments Address Category Status View
SMOKE & CARBON DETECTORS BASEMENT 344 S KOSTNER AVE COMPLAINT PASSED View
DEFECTIVE FIXTURES WATER DAMAGED LIGHT FIXTURE IN BASEMENT BATHROOM 344 S KOSTNER AVE COMPLAINT PASSED View
NO PERMIT WIRING BASEMENT BUILDOUT 344 S KOSTNER AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL SOUTH ELEVATION/ EXTERIOR MASONRY WALL - WASHED OUT MORTAR.WEST ELEVATION/ VINYL SIDING - LOOSE AND BUCKLED WITH HOLES. 344 S KOSTNER AVE COMPLAINT PASSED View
CONNECT DOWNSPOUT TO SEWER SOUTH AND REAR ELEVATIONS/ DOWNSPOUTS - NOT CONNECTED TO SEWER. 344 S KOSTNER AVE COMPLAINT PASSED View
REPAIR WINDOW SILLS SOUTH ELEVATION/ STONE SILLS - WASHED OUT MORTAR AND SHIFTING STONES. 344 S KOSTNER AVE COMPLAINT PASSED View
MAINTAIN WINDOW SOUTH ELEVATION/ BASEMENT WINDOWS - MISSING CASING AROUND WINDOWS. 344 S KOSTNER AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM WINDING STAIRCASE FROM BASEMENT TO 1ST FLOOR. TREADS ONLY 8" WIDE. RISER HEIGHTS NOT UNIFORM, VARY FROM 6.25" TO 11.25". 344 S KOSTNER AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS BASEMENT AND 1ST FLOOR APARTMENT/ SMOKE DETECTORS - MISSING 344 S KOSTNER AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT AND 1ST FLOOR APARTMENT/ CARBON MONOXIDE DETECTORS - MISSING. 344 S KOSTNER AVE COMPLAINT PASSED View
CEILING HEIGHT - 7' - BASEMENT BASEMENT/ CEILING - HEIGHT ONLY 6' 1" 344 S KOSTNER AVE COMPLAINT PASSED View
POULTRY-UNSANITARY CONDITIONS REAR ENCLOSED PORCH/ 2ND FLOOR DECK - CHICKEN COOP WITH ROOSTER IN IT. 344 S KOSTNER AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT SPACE FINISHED WITHOUT A PERMIT AND DUPLEXED INTO 1ST FLOOR APARTMENT. NO PERMIT OBTAINED. PLANS AND PERMIT FOR 1ST FLOOR TO BASEMENT DUPLEX ARE NOW REQUIRED. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 344 S KOSTNER AVE COMPLAINT PASSED View
WORK NOT ALLOWED BASEMENT SPACE FINISHED WITHOUT A PERMIT AND DUPLEXED INTO 1ST FLOOR APARTMENT. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 344 S KOSTNER AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 2-STORY ENCLOSED PORCH - UNDERSIZED 2X8 JOISTS SPAN 10'. STAIR RISER HEIGHTS VARY FROM 4.5" TO 8.25". RAILINGS ONLY 30" HIGH. ALSO LOOSE AND PULLING. ENTIRE PORCH LEANING AWAY FROM BUILDING.PLANS AND PERMIT REQUIRED TO REPAIR REAR ENCLOSED PORCH. 344 S KOSTNER AVE COMPLAINT PASSED View