The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE SERVICE. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | MORTAR EROSION WEST AND EAST ELEVATION AT PARAPET. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR COPING | MORTAR EROSION AT COPING-SOUTH ELEVATION. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT SIGN ON BUILDING. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | AT SOUTH ELEVATION LOOSE STONES AT CONCRETE PORCH LOOSE HANDRAILS ARE LOOSE;MISSING FOUNDATION STONES. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | MISSING STABILIZER ROD FOR CYCLONE FENCE-EAST ELEVATION. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ROTTED WINDOW FRAMES-WEST ELEVATION. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | JUNK AND DEBRIS ON LANDING AT 1ST FLOOR REAR PORCH. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH WITH COLUMNS OUT-OF-PLUMB.BEAMS ARE NOT PROPERLY ATTACHED TO COLUMNS;UNDERSIZED COLUMNS SUPPORTING STRINGER REST ON INSIDE WING WALL;WING WALL PARTIALLY COLLAPSED.MORTAR EROSION AND FRACTURES IN WEST MASONRY WALL. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | ABANDONED AUTO(S) IN REAR. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | DRUG PARAPHERNALIA IN WEST WALKWAY. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | A-TYPE METER OUTSIDE REAR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | STRAP & SECURE RACEWAY UNDER REAR PORCH 1/4 EMT. STRAP 1ST & 2ND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
SYSTEM III | OPEN JUNCTION BOX BASEMENT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | MISSING CHIMNEY CAP EAST ELEVATION | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS FRONT INTERIOR STAIRS & BASEMENT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | PARAPET WALL IS BULGING OUTWARD EAST ELEVATION, DOWN SPOUT & HAZARDOUS LOOSE BRICKS WEST ELEVATION FRONT & REAR, LOOSE STONE WASH SOUTH ELEVATION | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | OPEN MORTAR JOINTS EAST & WEST ELEVATION, DANGEROUS & LOOSE BRICKS WEST ELEVATION | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | LOOSE HAND RAIL FRONT PORCH | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | SECOND FLOOR FRONT BEDROOM DOOR HINGES ARE LOOSE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | BROKEN SIDE WALK WEST ELEVATION | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | LOOSE HAND RAIL 1ST TO 2ND FLOOR INTERIOR, MISSING HAND RAIL BASEMENT TO 1ST FLOOR REAR INTERIOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | FLOOR IS SPONGY AT 2ND FLOOR BATHROOM | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | MISSING SECTION AT BALCONY DECORATIVE STONE WASH SOUTH ELEVATION | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | LOOSE WOODEN PANELING 1ST FLOOR BEDROOM | 5318 W RACE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | LOOSE WINDOW SASH 1ST FLOOR & NORTH | 5318 W RACE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | DEAD BOLT LOCKS ON BEDROOM DOORS AT 1ST & SECOND FLOORS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | LOOSE CEILING TILES FROM BEDROOM SECOND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR AT 1ST FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNER I.D. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | TORN LINOLEUM AT 2ND FLOOR BATHROOM 1ST FLOOR KITCHEN | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 2 BEDROOM DOORS ARE MISSING AT 2ND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | LOOSE GAP AT BASE OF 2ND FLOOR DOOR AT SECOND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | MISSING DEAD BOLT LOCK 2ND FLOOR REAR DOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | HIGH WEEDS AT FRONT & REAR YARD | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | GAP AT BASEMENT DOOR NORTH | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | MISSING BROKEN FENCE SECTIONS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: MISSING SCUTTLE HATCH, 8"X2" HOLE BURNED INTO 2ND FLOOR DECK, ROTTED ROOF RAFTER AND LOOK-OUT, HAND RAILS 38" IN HEIGHT 8"X8" LOOK-OUTS EXTENDS 12 FOOT, IMPROPER LOOK-OUT TO UPRIGHT CONDITION AT BRIDSMOUTH ABOUT 1" IS BEARING WEIGHT, IMPROPER FOUNDATION FOR UPRIGHT (CONCRETE BLOCK), LOOSE TREADS BASEMENT GRADE. MISSING HAND RAIL BASEMENT TO GRADE-TREADS ARE 9 1/4 THROUGH OUT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR BUT NOT LIMITED TOO: AT REAR PORCH REPAIR B) MASONRY WORK C) STEEL PICKET FENCE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | P.V.C SUPPLIES AT LAVATORY WATER CLOSET KITCHEN SINK 1ST & 2ND FLOORS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | LAVATORY HAS VERY LOW WATER PRESSURE. MISSING TUB HANDLES 2ND FLOOR NO WATER FROM KITCHEN SINK 1ST FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | SECURE LAVATORY TO WALL 2ND FLOOR. RAW SEWAGE IN BASEMENT AT BASE OF SOIL STACK. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH DEVICE | FLUSH DEVICE WATER CLOSER 1ST FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ROD OUT LAVATORY & BATHTUB 1ST FLOOR REAR STAIRWELL DRAIN & HOUSE DRAIN. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | NO HOT WATER THROUGH OUT BUILDING 1ST & 2ND FLOORS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | CLEAN OUT CATCH BASIN IN REAR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROVIDE TRAP FOR FIXTURE | BATHTUB TRAP MUST BE DIRECTLY BELOW FIXTURE DRAIN . BASEMENT CEILING | 5318 W RACE AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | TO CORRECT ALL PLUMBING VIOLATIONS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 5318 W RACE AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR HOTWATER HTR | FOR THE INSTALLATION OF ELECTRIC WATER HEATER | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN DISTRIBUTION PANELS BASEMENT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | SECURE LAVATORY TO WALL 2ND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | EAST ELEVATION MISSING CHIMNEY CAP | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION LOOSE BRICK DANGEROUS & HAZARDOUS EAST & WEST ELEVATIONS OPEN MORTAR JOINTS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH LOOSE HANDRAIL | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT & FRONT INTERIOR STAIRS MISSING SMOKE DETECTORS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRS FROM 1ST TO 2ND & REAR STAIRS FROM BASEMENT TO 1ST MISSING HANDRAIL | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION AT BALCONY MISSING SECTION OF DECLARATIVE STONE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR AT REAR BEDROOM LOOSE WOODEN PANELING | 5318 W RACE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | NORTH & SOUTH ELEVATIONS AT 1ST FLOOR LOOSE WINDOW SASHES | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | SECOND FLOOR AT FRONT BEDROOM LOOSE CEILING TILE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR MISSING CARBON MONOXIDE DETECTOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR KITCHEN & 2ND FLOOR BATHROOM TORN LINOLEUM | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 2ND FLOOR MISSING 2 BEDROOM DOORS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | LOOSE & MISSING PUTTY AT 1ST & 2ND FLOOR WINDOWS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | 2ND FLOOR AT REAR DOOR MISSING DEADBOLT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | LARGE CAP AT NORTH BASEMENT DOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | MISSING & BROKEN SECTIONS OF FENCE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH MISSING ROOF HATCH BURNT DECKING AT 2ND FLOOR ROTTED LOOK-OUTS & ROOF JOIST RAILS AT 38" IN HEIGHT LOOK-OUT BEAMS 12' SPAN INPROPER BEAM TO COLUMN CONNECTIONS OPEN FIRE CUTS (BEARING) 9'1/4" TREADS THROUGH OUT LOOSE TREADS FROM BASEMENT TO GRADE CONCRETE BLOCK FOUNDATION MISSING HANDRAIL FROM BASEMENT TO GRADE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE PVC SUPPLIES AT LAVATORY KITCHEN SINK & WATER CLOSET ST & 2ND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | LAVATORY HAS LOW WATER PRESSURE 2ND FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH DEVICE | FLUSH DEVICE WATER CLOSET 1ST FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ROD OUT LAVATORY & BATH TUB 1ST FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | NO HOT WATER THROUGH OUT BUILDING | 5318 W RACE AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | CLEAN OUT CATCH BASIN IN REAR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROVIDE TRAP FOR FIXTURE | BATHTUB TRAP MUST BE DIRECTLY BELOW FIXTURE DRAIN BASEMENT CEILING | 5318 W RACE AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | TO CORRECT ALL PLUMBING VIOLATIONS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 5318 W RACE AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR HOTWATER HTR | FOR THE INSTALLATION OF ELECTRIC WATER HEATER | 5318 W RACE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | A-TYPE METER BOX OUTSIDE REAR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | SECURE RACEWAY UNDER REAR PORCH 172" EMT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | ELECTRICAL OPEN DISTRIBUTION PANEL BASEMENT | 5318 W RACE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST ELEVATION BROKEN SERVICE WALK | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND FLOOR BATHROOM SPONGY FLOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN JUNCTION BOX BASEMENT AREA | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | SECOND FLOOR FRONT BEDROOM LOOSE DOOR HINGES | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF AN EXISTING 2 STORY MASONRY BUILDING INCLUDING BUT NOT LIMITED TO:REMOVED AND RELOCATED PARTITIONS AT FIRST AND SECOND FLOOR.ERECTING NEW GARAGE AT REAR, ALLEY ACCESS. | 5318 W RACE AVE | COMPLAINT | CLOSED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 5318 W RACE AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | BEAMS NOT PROPERLY ANCHORED AT MASONRY WALL MISSING BEAM SUPPORT ANCHOR OR STEEL STRAP. | 5318 W RACE AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | LOOSE & MISSING PUTTY AT 1ST & 2ND FLOORS | 5318 W RACE AVE | COMPLAINT | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | BATH TUB 2ND FLOOR PAINT IS WORN AWAY | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR PORCH REPAIR MASONRY WORK IRON FENCE | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | MISSING SCREW DOOR CLOSER 2ND FLOOR REAR | 5318 W RACE AVE | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | 2ND FLOOR REAR MISSING CLOSER AT SCREEN DOOR | 5318 W RACE AVE | COMPLAINT | FAILED | View |