The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST BUILDING MANAGEMENT IDENTIFICATION AT EXTERIOR | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REPLACE WORN, LOOSE AND ROTTEN DOORS AT: 1) TWO ON FIRST FLOOR AT EAST ELEVATION; 2) THREE ON FIRST FLOOR AT SOUTH ELEVATION; 3) ONE AT WEST ELEVATION. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | REPLACE WORN AND ROTTEN DOOR FRAMES AT: 1) TWO ON FIRST FLOOR AT EAST ELEVATION; 2) THREE ON FIRST FLOOR AT SOUTH ELEVATION; 3) ONE AT WEST ELEVATION. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | REPLACE WORN, LOOSE AND ROTTEN WINDOW SASH AT: 1) ALL LEVELS AT SOUTH ELEVATION; 2) FIRST FLOOR AT NORTH ELEVATION. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REPLACE WORN, LOOSE AND ROTTEN WINDOW FRAMES AT: 1) ALL LEVELS AT SOUTH ELEVATION; 2) FIRST FLOOR AT NORTH ELEVATION. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REPLACE DOWNSPOUTS AT: 1) DOWNSPOUT BADLY RUSTED AT NORTH ELEVATION; 2) LOWER SECTION OF DOWNSPOUT MISSING AT SOUTH ELEVATION. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REPLACE DANGEROUS AND HAZARDOUS EXTERIOR WOOD STAIR SYSTEM AT WEST ELEVATION: 1) STRINGERS, NEWEL POSTS, TREADS AND RISERS WORN, LOOSE AND ROTTEN; 2) HANDRAIL SYSTEM WORN, LOOSE AND ROTTEN; 3) PICKETS ARE LOOSE AND MISSING. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE SERIES OF DILAPIDATED WOOD FRAME ADDITIONS AND ENCLOSURES FROM GROUND LEVEL TO ROOF AT WEST ELEVATION: 1) CONSTRUCTED WITHOUT PLANS AND PERMITS; 2) AMATEURISH CONSTRUCTION; 3) IMPROPER FOUNDATION; 4) STRUCTURES ARE SAGGING, LEANING AND HAVE BOWED WALLS; 5) FASCIA BOARD MISSING AT FIRST FLOOR LEVEL WITH EXPOSED WOOD FRAMING AND INSULATION; 6) SIDING MISSING AND DAMAGED AT MISCELLANEOUS LOCATIONS; 7) WALL SHEATING AND SIDING MISSING ON SECOND FLOOR LEVEL WITH EXPOSED WALL FRAMING MEMBERS; 8) REAR ENTRY DOOR TO STAIR ENCLOSURE BADLY DAMAGED. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REMOVE LARGE ACCUMULATION OF DEBRIS FROM REAR YARD. SEE PAPER, WOOD, BRICKS, INSULATION AND HOUSEHOLD WASTE. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REMOVE OVER GROWTH OF WEEDS, TALL GRASS AND SHRUBS AT REAR YARD. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - ADDRESS NUMBERS MISSING. | 1306 S KOLIN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN NOT POSTED. | 1306 S KOLIN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / NO RSPONSE , UNVERIFIED DTECTORS AND OCCUPANCY.UNABLE TO INSPECT INTERIOR STAIRWAY AND REAR PORCH. | 1306 S KOLIN AVE | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | 3-STORY / REAR ENCLOSED PORCH REPAIRED UNDER PERMIT 100211515, ISSUED ON 6/23/2008 - PLANS AND PERMIT NOT AVALIABLE ON SITE FOR INSPECTOR'S REVIEW AND WORK APPROVAL. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 1ST FLOOR / STORE FRONT - REHAB WORK IN PROGRESS WITHOUT A PERMIT. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL REHAB WORKS - SUBJECT TO FIELD INSPECTIONS AND APPROVAL BY ALL RELATED TRADES. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST ELEVATION - BOWED AND RUSTED LINTELS. PERMIT REQUIRED FOR REPLACEMENTS. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION 1ST TO 2ND FLOOR STAIRS - LOOSE HANDRAILS,CRACKED TREADS WITH BROKEN OFF NOSINGS,FALL HAZARD. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST ELEVATION - BOWED AND RUSTED LINTELS. PERMIT REQUIRED FOR REPLACEMENTS. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION 1ST TO 2ND FLOOR STAIRS - LOOSE HANDRAILS,CRACKED TREADS WITH BROKEN OFF NOSINGS,FALL HAZARD. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | NORTH, SOUTH AND EAST ELEVATIONS - FRACTURES LOOSE AND ERODED MORTAR AT VARIOUS LOCATIONS. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
PARAPET | NORTH AND SOUTH ELEVATIONS - FRACTURES, LOOSE AND ERODED BRICKS / MORTAR . | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR WINDOW SILLS | EAST ELEVATION - OPEN SILL JOINTS | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR SCREENS | ALL ELEVATIONS / GRADE TO 3RD FLOOR SCREENS - MISSING / TORN IN VARIOUS LOCATIONS THROUGHOUT. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 2ND AND 3RD FLOOR APARTMENTS / SMOKE DETECTORS - NOT WORKING / NOT INSTALLED AT TIME OF INSPECTION. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
PROVIDE | REGISTER VACANT BUILDING WITH DEPARTMENT OF BUILDINGS (13-12-125) | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REPLACE BROKEN WINDOW PANES AT FIRST AND SECOND FLOOR AT WEST ELEVATION. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION - OPEN SILL JOINTS | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH, SOUTH AND EAST ELEVATIONS - FRACTURES LOOSE AND ERODED MORTAR AT VARIOUS LOCATIONS. | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH ELEVATIONS - FRACTURES, LOOSE AND ERODED BRICKS / MORTAR . | 1306 S KOLIN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | CALL (312) 743-0413 | 1306 S KOLIN AVE | COMPLAINT | PASSED | View |
RMV OBSTRN FROM HSE DRAIN PIPE | TOLIET AND BATHTUB ARE BACKED UP WITH WASTE AND NOT DRINING PROPERLY - SINK LAVATORY IN BATHROOM IN APARTMENT, 1ST FLOOR-REAR | 1306 S KOLIN AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | FRONT AND REAR INTERIOR STAIR SYSTEMS / GRADE TO 3RD FLOORINTERIOR WALLS / CEILINGS - HOLES / PATCHES AND UNFINISHED REPAIRS EXPOSING PLASTER / DRYWALL THROUGHOUT IN VARIOUS LOCATIONS | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR INTERIOR STAIR SYSTEM | GRADE TO 3RD FLOOR / FRONT AND REAR INTERIOR STAIR SYSTEMS/ TREADS / WINDERS - VARY LOOSE, CUPPING AND SQUEAKING. WINDERS AT /2ND TO 3RD FLOOR FRONT / ARE COLAPSING IN VARIOUS LOCATIONS THROUGHOUT. ENTIRE FRONT STAIR SYSTEM GRADE TO 2ND FLOOR ARE OUT OF PLUMNB.PERMIT REQUIRED FOR ALL REPAIRS TO STAIR SYSTEM. ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL UPON COMPLETION | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS / 2ND AND 3RD FLOOR APARTMENTS / WINDOWS - DONT OPEN / HARD TO OPEN, COME COMPLETLY OUT WHEN OPENED IN VAIROUS LOCATIONS THROUGHOUT. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION / GRADE TO 2ND FLOOR /TREADS - UNEVEN RISER HEIGHTS, NOSING BROKEN OFF, AND CRACKING CAUSING TRIPPING HAZARD. INADEQUATELY BUILT OVER 12' IN RISE WITHOUT A LANDING CAN BE VARY DANGEROUS.HANDRAILS - VARY LOOSE, AND DETERIORATING, MISSING PROPER HARDWARE. FASTENED WITH RUSTING NAILSSTAIRS NEED TO BE PROFESSIONALLY REDESIGNED WITH A LANDING.PLANS AND PERMIT REQUIRED TO REPLACE / REPAIR EXTERIOR STAIR SYSTEM. ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL UPON COMPLETION. | 1306 S KOLIN AVE | COMPLAINT | CLOSED | View |