Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY CAPPING | CHIMNEY - MISSING CAPPING. | 7701 S NORMAL AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT TO GRADE STAIRWAY - MISSING HANDRAIL. | 7701 S NORMAL AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRWAY - MISSING GUARDRAIL SECTIONS AT GRADE. | 7701 S NORMAL AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | 2-STORY REAR PORCH WITH 12' X 18' WIDE DECKING AT 1: 4X4 AND 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. JOISTS ARE ONLY TOE-NAILED TO BEAMS, AND STRINGERS ARE ONLY TOE-NAILED TO COLUMNS. GUARDRAIL SECTIONS SPAN 11 FEET, WITH PICKETS LOOSE AND BROKEN. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 7701 S NORMAL AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO VERIFY COMPLAINTS OF MOLD AND WATER DAMAGE AT 1ST FLOOR. | 7701 S NORMAL AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 7701 S NORMAL AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NORTH AND SOUTH CHIMNEYS - CAPPINGS - MISSING. | 7701 S NORMAL AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRWAY - GUARDRAIL SECTIONS - MISSING AT GRADE. | 7701 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2-STORY REAR PORCH WITH 12 FT X 18 FT EXTENDED DECK AT 1ST FLOOR: 4X6 AND 6X6 COLUMNS ARE ERECTED ON CONCRETE BLOCKS WITHOUT BASES - FOUNDATION STATUS UNKNOWN; JOISTS ARE ONLY TOE-NAILED TO COLUMNS; GUARDRAIL SECTIONS SPAN 18 FEET WITHOUT INTERMIDATE POSTS; GUARDRAIL PICKETS MISSING AT 2; RAILINGS LOOSE AND PULLING. FRONT GRADE TO 1 / PORCH: UNDERSIZED 2X6 JOISTS SPAN 12 FEET AND ONLY TOE-NAILED TO RIM BEAM; RAILINGS WITH LOOSE AND BROKEN PICKETS. PLANS AND PERMIT REQUIRED TO REPAIR BOTH PORCHES. | 7701 S NORMAL AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS - LOOSE AND TORN SCREENS. | 7701 S NORMAL AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BLDG. - POSTED ADDRESS - NOT READABLE FROM STREET, NUMBERS ARE NOT VISIBLE. | 7701 S NORMAL AVE | COMPLAINT | FAILED | View |