The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN OR REPAIR HYDRO ELEVA | OBTAIN PERMIT TO PROPERLY REMOVE ELEVATOR | 7600 S STEWART AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROPERLY SECURE HOISTWAY DOORS FOR ELEVATOR | 7600 S STEWART AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE MAINTENCE CONTROL PROGRAM (MAINTENANCE LOGS).LOGS MUST INCLUDE MONTHLY FIRE SERVICE TESTING LOGS. ALL ELEVATORS. | 7600 S STEWART AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR ELEVATOR FOR PROPER OPERATION. | 7600 S STEWART AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE MEANS OF 2 WAY COMMUNICATION INSIDE ELEVATOR. EMERGENCY PHONE SHALL CONTACT A 24 HOUR LIVE OPERATOR (NOT TO DIAL 911). MUST BROADCAST BUILDING ADDRESS AND ELEVATROR NUMBER. | 7600 S STEWART AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PERFORM CATEGORY 1 TEST ON ALL ELEVATORS. TEST MUST BE PERFORMED BY LICENSED ELEVATOR CONTRACTOR. MUST PROVIDE DOCUMENTATION AND TAG/SEAL RELIEF VALVE. | 7600 S STEWART AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR DOOR MISSING AT FRONT OF PROPERTY EAST ELEVATION | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILING WATER DAMAGED AT COMMON AREA 1ST FLOOR SOUTH SECTION, UNIT 204 BATHROOM CEILING COLLAPSED FROM WATER DAMAGES, UNIT 104 BATHROOM CEILING COLLAPSING FROM WATER DAMAGES. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | UNIT 204 BATHROOM CEILING OPEN AND EXPOSED CEILING JOISTS SEVERE TERMITE DAMAGES 136026 | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | MICE RODENT INFESTATION THROUGHOUT PROPERTY, EXTERMINATION REQUIRED. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
ROACHES | ROACH INFESTATION THROUGHOUT PROPERTY EXTERMINATION REQUIRED. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY UNIT 101-02-03, 205-06-07-08-02, 301-02-04. FULL INTERIOR INSPECTION REQUIRED FOR ENTIRE PROPERTY. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING/NOT OPERATING SMOKE DETECTORS UNITS 104,105,106,107,305 INSURE ENTIRE PROPERTY HAS FUNCTIONING SMOKE DETECTORS THROUGHOUT. DANGEROUS AND HAZARDOUS CONDITIONS. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING PAINT EAVES ENTRY CANOPY ALL ELEVATIONS | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXABLE SUPPLY TO KITCHEN FAUCET, LAV, AND TOILET, UNIT 3E | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
SYSTEM III | INSTALL EMERGENCY LIGHTING SYSTEM III, INSTALL ADDITIONAL BATTERY PACKS TO MAIN ENTRY DOORS. PROVIDE EMERGENCY LIGHTING PLAN. REMOVE IMPROPER CONNECTIONS FROM EXISTING BATTERY PACKS TO LIGHT FIXTURES | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT ELECTRICAL VIOLATIONS 13-12-360 | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
CARB MONOX DETECT IN RESID | MISSING CARBON DIOXIDE DETECTOR IN LAUNDRY ROOM WHERE FOSSIL FUEL IS BEING USED FOR DRYER. DANGEROUS AND HAZARDOUS. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | LOOSE FIXTURE REAR PORCHES | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | INTERIOR HALLWAY DOOR AT 2ND FLOOR NORTH MISSING LITE | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | HALLWAYS ALL LEVELS UNFINISHED FLOORS | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | VARIOUS EM LIGHTS NOT OPERABLE. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | NO BACKFLOW PREVENTER TO BOILER AT BASEMENT MECHANICAL ROOM 18-29-602 | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | OPEN STUDDED WALL IN STORAGE ROOM LOCATED AT THE 1ST FLOOR NON COMBUSTIBLE MATERIAL REQUIRED FOR THIS AREA. (13-160-220) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | LEAK ABOVE TUB AT UNIT 104 CAUSING CEILING TO CAVE IN. LEAKING KITCHEN SINK TUBULAR DRAINAGE PIPING IN UNIT 204. (18-29-102.3) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | LOOSE KITCHEN SINK HANDLE AT UNIT 105 LOOSE SHOWER VALVE HANDLE AT 204 (18-29-102.3) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED FLEXIBLE WATER SUPPLIES TO BATHROOM TOILET AND LAVATORY IN UNIT 108 (18-29-605) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE SOIL PIPING | KITCHEN SINK AND BATHROOM LAVATORY CLOGGED NOT DRAINING WATER AT UNIT 104. (18-29-102.3) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | UNAPPROVED PVC UNDERGROUND PIPING TO LAUNDRY WASTE AT BASEMENT LAUNDRY ROOM. (18-29-702) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | INADEQUATE HOT WATER THROUGHOUT PREMISES TO KEEP FIXTURES CLEAN AND SANITARY. (13-196-430) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING, OR USING PLUMBING SYSTEM. (13-12-080, 13-12-010) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. (18-29-106.1) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | SERVICE CABLES SEVERELY DETERIORATED | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
CORD TO FIXTURE | UNAPPROVED CORD WIRE LIGHT FIXTURES AT TOP REAR EXTERIOR STAIRS.. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
ALL EXTERIOR LIGHT FIXTURES, BOXES, FITTINGS, DEVICES MUST BE SUITABLE FOR WET LOCATION. (14E-1-110.3) | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
EXPOSED WIRING FIXTURES | EXPOSED WIRING BEHIND LIGHT FIXTURE AT NORTH END REAR EXTERIOR LOWER LEVEL. DANGEROUS AND HAZARDOUS. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
SYSTEM II | UNAPPROVED EM LIGHT AT 1ST FLOOR FRONT FOYER | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE WORKING SPACE FOR MAIN ELECTRICAL SERVICE EQUIPMENT AT 1ST FLOOR AND APARTMENT G101 PANEL, APARTMENT 201 PANEL, APARTMENT 204 PANEL AND WHERE REQUIRED IN TYPICAL UNITS AND SPACES THROUGHOUT 1ST FLOOR, 2ND FLOOR, 3RD FLOOR. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLAVE CORRODED DEVICES IN APARTMENT G101 KITCHEN AND WHERE REQUIRED IN TYPICAL UNITS AND SPACES THROUGHOUT 1ST FLOOR, 2ND FLOOR, 3RD FLOOR. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | INSTALL GLOVE/COVER FOR LIGHT FIXTURE IN APARTMENT 204 CLOSET AND WHERE REQUIRED IN TYPICAL UNITS AND SPACES THROUGHOUT 1ST FLOOR, 2ND FLOOR, 3RD FLOOR. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
DOOR/ACCESS/INTERCOM SYSTEM INOPERABLE (14E-7-725.31) | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
INSTALL COVER ON MAIN PHONE DISTRIBUTION ENCLOSURE LOCATED IN 1ST FLOOR LAUNDRY AREA. (14E-1-110.3) | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
INSTALL GFCI PROTECTION IN 1ST FLOOR LAUNDRY AND MECHANICAL AREA AND WHERE REQUIRED IN TYPICAL UNITS AND SPACES THROUGHOUT 1ST FLOOR, 2ND FLOOR, 3RD FLOOR.14E-2-210.8) | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
PROVIDE PERMIT TO CORRECT VIOLATIONS. (13-12-360) | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
REMOVE | REMOVE ALL GAS POWERED MACHINERY FROM STORAGE ROOM LOCATED AT THE 1ST FLOOR. DANGEROUS AND HAZARDOUS. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | OBTAIN PERMIT TO REMOVE/DECOMMISSION ELEVATOR. PREVIOUSLY CITED. | 7600 S STEWART AVE | PERIODIC | FAILED | View |
18-27-210.2 INSTALL ARC FAULT BREAKERS TO BEDROOMS. | 7600 S STEWART AVE | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE ONE LINE DIAGRAM AND LOAD CALCULATION FOR ELECTRICAL SERVICE FEEDER. (14E-215.5, 14E-2-220.40) | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | RESTORE ELEVATOR TO SAFE, NORMAL OPERATION. ELEVATOR NOT RUNNING UPON ARRIVAL. PREVIOUSLY CITED. | 7600 S STEWART AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS / SCREENS - MISSING AND TORN IN VARIOUS LOCATIONS. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | ENTRY DOOR / GLASS - BROKEN AND LAYING IN THE FOYER. | 7600 S STEWART AVE | COMPLAINT | FAILED | View |