The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | SR06-015922345 - INTERIOR OF BUILDING - UNABLE TO VERIFY COMPLAINT OF RATS INFESTATION AT 33 N. LOREL APARTMENT #2 WEST - UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND PREVIOUS VIOLATIONS. NO ENTRY TO INTERIOR STAIRWAY AND PORCH SYSTEM. | 31 N LOREL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE PREMISE INSPECTIONMOST APARTMENTS - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION / FENCE - RAILING MISSING, FENCE LEANING. | 31 N LOREL AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT OF BUILDING / SERVICE WALK - CONCRETE BROKEN, CRACKED. | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH PORCH REAR PICKETS MISSING 3RD FLOOR, 2ND FLOOR, COLUMN 4X4 FOR 3 STORIES UNDERSIZED STRINGERS IMPROPERLY CUT LEDGER BOARDS INSUFFICIENT BOLTS SOUTH PORCH REAR COLUMN SPLIT CRACKED AND TWISTED (NORTH COLUMN ON SOUTH PORCH) NO LEDGER BOLTS JOIST BEAM POCKETS LOOSE MORTAR | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | APARTMENT 2W REAR EXTERIOR DOOR, FRONT ENTRANCE 35 (N) DOOR BROKEN | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST WALL ERODED MORTAR BRICKS SPALLED AND MISSING SOUTH WALL OPEN JOINTS | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | 3RD FLOOR CENTER LINTEL RUSTED SAGGING | 31 N LOREL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | FURNACE ROOM AT BASEMENT, 2 WEST APARTMENT | 31 N LOREL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERS ID | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN PANES AT 3RD FLOOR BASEMENT VARIOUS LOCATIONS DOOR TRANSOM 35 (N) | 31 N LOREL AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | JUNK AND DEBRIS 3RD FLOOR DECK REAR PORCH | 31 N LOREL AVE | PERIODIC | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | EMERGENCY LIGHTS OUT AT 2 INTERIOR | 31 N LOREL AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK SIDEWALK CRACKED (SOUTH) HOLES IN CONCRETE | 31 N LOREL AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 2 WEST APARTMENT FURNACE ROOM | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | REPAIR BASEMENT CEILING LATH FALLING HOLES IN CEILING | 31 N LOREL AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT TO REPAIR REAR PORCHES | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 35 FRONT EXTERIOR DOOR BROKEN GLASS, 35 1W REAR DOOR GAPS ARROUND DOORS, 35-2E REAR DOOR GAPS AROUND DOORS | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 35-1W REAR DOOR DOOR KNOB LOOSE | 31 N LOREL AVE | PERIODIC | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 35 2E ALL ELEVATIONS LEAKING AIR WON'T SEAL | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | 35 2E BATHTUB LOWW PRESSURE FROM FAUCET & SHOWER HEAD | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | 35 2E BATHTUB ENAMEL PEELING OFF | 31 N LOREL AVE | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | 35 FRONT EXTERIOR DOOR NO LOCK | 31 N LOREL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 35 FRONT STAIRWAY DEFECTIVE SMOKE DETECTORS, APARTMENT 2E NO SMOKE DETECTOR | 31 N LOREL AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 35 APARTMENT 2E NO CARBON MONOXIDE DETECTOR | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 35 REAR PORCH GRADE TO 3RD RAILS TOO SHORT, MISSING PICKETS STRINGERS SPLICED TOGETHER. 33 REAR PORCH GRADE TO 3RD COLUMNS NOT PROPERLY SPLICED & BOLTED, OVERNOTCHED, JOIST ARE MISSING JOIST HANGERS STRINGERS ARE NOT PROPERTY ATTACHED RAILS ARE TOO SHORT COLUMNS NOT SET ON PROPER FOOTING | 31 N LOREL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS & PERMIT TO REPAIR BOTH REAR PORCHES | 31 N LOREL AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICE WALK BROKEN CONCRETE | 31 N LOREL AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS BROKEN & MISSING SCREENS | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | VARIOUS LOCATION BROKEN PANES | 31 N LOREL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING .NO RESPONSE | 31 N LOREL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR INSPECTION OF ALL UNITS TO VERIFY DETECTORS | 31 N LOREL AVE | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 35 FRONT DOOR TO BASEMENT BROKEN | 31 N LOREL AVE | PERIODIC | FAILED | View |