The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALL SPALLED BRICKS AND STEP FRACTURES AT MORTAR JOINTS, ALLEY SIDE, REAR AND SOUTH. | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. UNABLE TO VERIFY OCCUPANCY AND DETECTORS. | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS. (14A-4-404.6 & 14A-4-404.6.1) | 1217 S KEELER AVE | COMPLAINT | FAILED | View | |
LISTED FOR USE TEMP & LOCATION | MISSING WEATHERPROOF BOXES ON THE EXTERIOR NORTH ELEVATION OF THE BUILDING. | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS FRONT, NORTH AND SOUTH ELEVATIONS WASHED OUT MORTAR. | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
ABANDONED EQUIPMENT | REMOVE ABANDONED PIPE ON THE REAR OF THE BUILDING ON THE EAST ELEVATION. | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | WEST ELEVATION FRONT ENTRY DOOR,GLASS BROKEN AND BOARDED. | 1217 S KEELER AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NO ADDRESS POSTED. | 1217 S KEELER AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR THREE STORY PORCH, 4X4 COLUMNS REST ON CONCRETE SLAB,FOUNDATION STATUS UNKNOWN.STRINGERS ALL LEVELS IMPROPERLY CUT, TREADS 12 1/2 INCHED IN DEPTH,INCONSISTANT RISER HEIGHTS,2ND AND 3RD FLORR STRINGERS ONLY SUPPORTED BY FLOATING 4X4 POST AND SINGLE BOLT.WINDERS AT 2ND AND 3RD FLOORS SUPPORTED BY TOP ENDS OF STRINGERS AND NAILED TO LEDGER ONLY. BEAM TO COLUMN CONNECTIONS NAILED ONLY. 4X4 COLUMNS BUTT JOINT CONSTRUCTION. 2X8 JOISTS SPAN 10'2. 4X4 BEAMS SQUARE CONNECTION AND NAILED ONLY. PLANS AND PERMITS REQUIRED FOR REPLACEMENT. | 1217 S KEELER AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NO ADDRESS POSTED. | 1217 S KEELER AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR THREE STORY PORCH, 4X4 COLUMNS REST ON CONCRETE SLAB,FOUNDATION STATUS UNKNOWN.STRINGERS ALL LEVELS IMPROPERLY CUT, TREADS 12 1/2 INCHED IN DEPTH,INCONSISTANT RISER HEIGHTS,2ND AND 3RD FLORR STRINGERS ONLY SUPPORTED BY FLOATING 4X4 POST AND SINGLE BOLT.WINDERS AT 2ND AND 3RD FLOORS SUPPORTED BY TOP ENDS OF STRINGERS AND NAILED TO LEDGER ONLY. BEAM TO COLUMN CONNECTIONS NAILED ONLY. 4X4 COLUMNS BUTT JOINT CONSTRUCTION. 2X8 JOISTS SPAN 10'2. 4X4 BEAMS SQUARE CONNECTION AND NAILED ONLY. PLANS AND PERMITS REQUIRED FOR REPLACEMENT. | 1217 S KEELER AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH MISSING BOLTS ON SPLICE CONNECTIONS INADEQUATE CONNECTION BEAM TO COLUMN MISSING BOLTS ON TOP OF STRINGERS ALSO ON ALL UPRIGHT POSTS AND COLUMNS THAT THE IN WITH RIM JOISTS RAIL HEIGHT IS ONLY 36" INCHES STRINGERS ARE OVER CUT MISSING BOLTS ON LEDGER BOARDS MID LANDING JOISTS ARE ONLY TOE NAILED SUBMITS PLANS AND OBTAIN PERMIT FOR REPAIRS ON REAR PORCH | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | 2ND FLOOR WINDOW FRAMES ROTTED | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING. | 1217 S KEELER AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5'. REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT. | 1217 S KEELER AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | ALL ELEVATIONS VARIOUS LOCATIONS THERE ARE WINDOW OPENINGS THAT HAVE BEEN IN-FILLED WITH BRICK AND DONE WITHOUT PROPER MASONRY PERMITS. | 1217 S KEELER AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION ABOVE 3RD FLOOR WINDOW SPALLING BRICK ERODED WASHED OUT MORTAR BETWEEN 3RD AND 2ND SEE STEP FRACTURES | 1217 S KEELER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING,NO RESPSONE TO VERIFY DETECTORS. | 1217 S KEELER AVE | PERIODIC | FAILED | View |