Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 10:05 PM
PIN: 16222040090000
Property Address: 1217 S KEELER AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 315
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77125
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL EXTERIOR WALL SPALLED BRICKS AND STEP FRACTURES AT MORTAR JOINTS, ALLEY SIDE, REAR AND SOUTH. 1217 S KEELER AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR. UNABLE TO VERIFY OCCUPANCY AND DETECTORS. 1217 S KEELER AVE COMPLAINT FAILED View
OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS. (14A-4-404.6 & 14A-4-404.6.1) 1217 S KEELER AVE COMPLAINT FAILED View
LISTED FOR USE TEMP & LOCATION MISSING WEATHERPROOF BOXES ON THE EXTERIOR NORTH ELEVATION OF THE BUILDING. 1217 S KEELER AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS WINDOW SILLS FRONT, NORTH AND SOUTH ELEVATIONS WASHED OUT MORTAR. 1217 S KEELER AVE COMPLAINT FAILED View
ABANDONED EQUIPMENT REMOVE ABANDONED PIPE ON THE REAR OF THE BUILDING ON THE EAST ELEVATION. 1217 S KEELER AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME WEST ELEVATION FRONT ENTRY DOOR,GLASS BROKEN AND BOARDED. 1217 S KEELER AVE PERIODIC FAILED View
NO POSTED ADDRESS NO ADDRESS POSTED. 1217 S KEELER AVE PERIODIC FAILED View
REPLACE D&H PORCH REAR THREE STORY PORCH, 4X4 COLUMNS REST ON CONCRETE SLAB,FOUNDATION STATUS UNKNOWN.STRINGERS ALL LEVELS IMPROPERLY CUT, TREADS 12 1/2 INCHED IN DEPTH,INCONSISTANT RISER HEIGHTS,2ND AND 3RD FLORR STRINGERS ONLY SUPPORTED BY FLOATING 4X4 POST AND SINGLE BOLT.WINDERS AT 2ND AND 3RD FLOORS SUPPORTED BY TOP ENDS OF STRINGERS AND NAILED TO LEDGER ONLY. BEAM TO COLUMN CONNECTIONS NAILED ONLY. 4X4 COLUMNS BUTT JOINT CONSTRUCTION. 2X8 JOISTS SPAN 10'2. 4X4 BEAMS SQUARE CONNECTION AND NAILED ONLY. PLANS AND PERMITS REQUIRED FOR REPLACEMENT. 1217 S KEELER AVE PERIODIC FAILED View
NO POSTED ADDRESS NO ADDRESS POSTED. 1217 S KEELER AVE PERIODIC FAILED View
REPLACE D&H PORCH REAR THREE STORY PORCH, 4X4 COLUMNS REST ON CONCRETE SLAB,FOUNDATION STATUS UNKNOWN.STRINGERS ALL LEVELS IMPROPERLY CUT, TREADS 12 1/2 INCHED IN DEPTH,INCONSISTANT RISER HEIGHTS,2ND AND 3RD FLORR STRINGERS ONLY SUPPORTED BY FLOATING 4X4 POST AND SINGLE BOLT.WINDERS AT 2ND AND 3RD FLOORS SUPPORTED BY TOP ENDS OF STRINGERS AND NAILED TO LEDGER ONLY. BEAM TO COLUMN CONNECTIONS NAILED ONLY. 4X4 COLUMNS BUTT JOINT CONSTRUCTION. 2X8 JOISTS SPAN 10'2. 4X4 BEAMS SQUARE CONNECTION AND NAILED ONLY. PLANS AND PERMITS REQUIRED FOR REPLACEMENT. 1217 S KEELER AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH MISSING BOLTS ON SPLICE CONNECTIONS INADEQUATE CONNECTION BEAM TO COLUMN MISSING BOLTS ON TOP OF STRINGERS ALSO ON ALL UPRIGHT POSTS AND COLUMNS THAT THE IN WITH RIM JOISTS RAIL HEIGHT IS ONLY 36" INCHES STRINGERS ARE OVER CUT MISSING BOLTS ON LEDGER BOARDS MID LANDING JOISTS ARE ONLY TOE NAILED SUBMITS PLANS AND OBTAIN PERMIT FOR REPAIRS ON REAR PORCH 1217 S KEELER AVE COMPLAINT FAILED View
MAINTAIN WINDOW 2ND FLOOR WINDOW FRAMES ROTTED 1217 S KEELER AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR OF BUILDING. 1217 S KEELER AVE COMPLAINT PASSED View
WORK NOT ALLOWED STEEL PICKET FENCE OVER 5'. REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT. 1217 S KEELER AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR ALL ELEVATIONS VARIOUS LOCATIONS THERE ARE WINDOW OPENINGS THAT HAVE BEEN IN-FILLED WITH BRICK AND DONE WITHOUT PROPER MASONRY PERMITS. 1217 S KEELER AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL EAST ELEVATION ABOVE 3RD FLOOR WINDOW SPALLING BRICK ERODED WASHED OUT MORTAR BETWEEN 3RD AND 2ND SEE STEP FRACTURES 1217 S KEELER AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING,NO RESPSONE TO VERIFY DETECTORS. 1217 S KEELER AVE PERIODIC FAILED View