Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 2:53 AM
PIN: 16094020240000
Property Address: 354 N CICERO AVE
City - Zip: CHICAGO - 60644
2023 Property Class: 318
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77026
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 63 Violations
Violation Inspector Comments Address Category Status View
INSTALL ILLUMINATION REAR PORCH EXTERIOR 354 N CICERO AVE COMPLAINT FAILED View
EXPOSED WIRING STORE FRONT OPEN TO PUBLIC REAR DANGEROUS AND HAZARDOUS ELECTRICAL PERMIT IS REQUIRED 354 N CICERO AVE COMPLAINT FAILED View
SYSTEM III STAIRWELL OF BUILDING 354 N CICERO AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT EXTERIOR DOOR TO STAIRWAY GAPS 356 3RD FLOOR REAR DOOR GAPS AROUND DOOR 354 N CICERO AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH STRINGER OVER CUT, MISSING RISERS, STAIR SYSTEM LEANING, BALUSTER LOOSE, BROKEN AND MISSING PICKETS, STAIR SYSTEM DECKING IMPROPER AND LOOSE, LEDGER MISSING ANCHOR BOLTS, LEDGER NOT NOTCH INTO COLUMNS, COLUMNS MISSING ANCHOR BOLTS, GUARDRAILS EXCESSIVE OPEN OVER 10". 354 N CICERO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS AND PERMIT TO REBUILD OR REPAIR REAR PORCH 354 N CICERO AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS VARIOUS LOCATIONS BROKEN PLANS 354 N CICERO AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER 356 2 N BATHROOM CEILING IS MISSING 354 3S BATHROOM CEILING BUCKLED 354 N CICERO AVE COMPLAINT FAILED View
REPAIR FLOOR 356 2N BATHROOM KITCHEN ROTTED SUBFLOOR MISSING FLOOR TILE 354 N CICERO AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE 356 2N TOILET LOOSE 354 N CICERO AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION REGISTERED BUILDING 1997 TO 2003 AND 2005 354 N CICERO AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 354 2ND FLOOR NO CARBON MONOXIDE DETECTOR 354 N CICERO AVE COMPLAINT FAILED View
ILLUMINATE EXIT AREAS REAR PORCH NO LIGHTS 354 N CICERO AVE COMPLAINT FAILED View
PRV RECEIVER 450# PSIG FOR ONE COPELAND 4 HG.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WALK-IN-COOLER, ONE COPELAND 6 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WALK-IN-COOLER, ONE COPELAND 2 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WALK-COOLER, ONE COPELAND 7-1/2 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WIC, ONE MANEUROP 5 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WIC. 354 N CICERO AVE PERIODIC FAILED View
CONNECT VENT LINE 5/8" OD TYPE K COPPER OR ACR TUBING WITH BRAZED CONNECTIONS, FOR ALL ABOVE LISTED UNITS. 354 N CICERO AVE PERIODIC FAILED View
TERMINATE VENT LINE FOR ALL ABOVE LISTED UNITS. 354 N CICERO AVE PERIODIC FAILED View
REMV OBSTR FROM DRAINAGE SYSTM 356 2ND KITCHEN SINK CLOGGED 354 N CICERO AVE COMPLAINT FAILED View
STOP LEAKING WATER 354 356 2ND FLOOR BATH ROOM WATER LEAKING FROM 3RD FLOOR 354 N CICERO AVE COMPLAINT FAILED View
PRV PLUGGED/CAPPED 4503 PSIG FOR ONE COPELAND 4 HP REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVNG WALK IN COOLER 354 N CICERO AVE PERIODIC FAILED View
PRV RECEIVER 450# PSIG FOR ONE COPELAND 4 HG.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WALK-IN-COOLER, ONE COPELAND 6 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WALK-IN-COOLER, ONE COPELAND 2 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WALK-COOLER, ONE COPELAND 7-1/2 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WIC, ONE MANEUROP 5 H.P. REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVING WIC. 354 N CICERO AVE PERIODIC FAILED View
CONNECT VENT LINE 5/8" OD TYPE K COPPER OR ACR TUBING WITH BRAZED CONNECTIONS, FOR ALL ABOVE LISTED UNITS. 354 N CICERO AVE PERIODIC FAILED View
TERMINATE VENT LINE FOR ALL ABOVE LISTED UNITS. 354 N CICERO AVE PERIODIC FAILED View
PRV PLUGGED/CAPPED 4503 PSIG FOR ONE COPELAND 4 HP REMOTE REFRIGERATION UNIT LOCATED IN REAR MECH ROOM SERVNG WALK IN COOLER 354 N CICERO AVE PERIODIC FAILED View
PRV RECEIVER 450# PSIG FOR ONE COPELAND 3 HP REMOTE REFRIGERATION UNIT LOCATED ON REAR MECH RM SERVING R.I.C. AND ONE COPELAND 6 HP REMOTE REFRIGERATION UNIT LOCATED OUTSIDE NORTH SERVING W.I.C. 354 N CICERO AVE PERIODIC FAILED View
CONTRARY TO ORIGINAL PLAN BUILDING ORIGINALLY: FOUR DWELLING UNITS, TWO EACH AT 2ND AND 3RD FLOORS AND 2 MERCANTILE AT 1ST FLOOR. CURRENT USE: 1ST FLOOR MERCANTILE, 2ND FLOOR ONE OFFICE AND ONE APARTMENT. 3RD FLOOR ONE APARTMENT USED AS LARGE MEDIA/STORAGE. 354 N CICERO AVE COMPLAINT FAILED View
REPAIR FLOOR 3RD FLOOR MECHANICAL ROOM/COMMON STAIRWAY SUB-FLOORING HAVE ROTTED WOOD AND 2ND FLOOR REAR. 354 N CICERO AVE COMPLAINT FAILED View
PROVIDE THE 2ND/3RD FLOORS THAT WERE CONVERTED FROM RESIDENTIAL TO COMMERCIAL STORAGE CHANGE THE REQUIRED LIVE LOADS ASSUMED IN THE DESIGN OF BUILDINGS AND OTHER STRUCTURES SHALL BE THE MAXIMUM LEADS LIKELY TO BE PRODUCED BY THE INTENDED USE OR OCCUPANCY. BUT SHALL IN NO CASE BE LESS THAN THE MINIMUM UNIFORMLY DISTRIBUTED UNIT LOADS REQUIRED. 16(13-52-090) DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
CONTRARY TO ORIGINAL PLAN OBTAIN PLANS AND PERMITS FOR BUT NOT LIMITED TO: ONE STORY MASONARY ADDITION AT REAR. MASONARY AND STEEL PICKET FENCE AT REAR PERIMETER OF BUILDING. STEEL STRUCTURE AT NORTH ELEVATION TO SUPPORT AIR CONDITIONING COMPRESSORS 1ST, 2ND AND 3RD FLOORS HAVE BEEN ENTIRELY REMODELED AND PARTIALLY RECONFIGURED. OLD MECHANICAL SYSTEMS HAVE BEEN REPLACED, ELECTRICAL, PLUMBING AND VENTILATION. NORTH INTERIOR STAIR CASE HAS BEEN ALTERED TO A SUB-STANDARD CONFIGURATION. STEEL COLUMNS AND BEAMS IN A SMALL AREA AT THE FRONT OF 1ST FLOOR HAVE BEEN INSTALLED. 354 N CICERO AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 1ST FLOOR MARKED EXIT PADLOCKED. 2ND/3RD FLOOR BLOCKED BY OVERSTOCK OF MERCHANDISE. REDUCED HALLWAY AT 35" - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR WEST ELEVATION HAS A ONE STORY CINDER BLOCK STRUCTURE. ALL WORK CONSTRUCTED WITHOUT PLANS AND PERMIT. 354 N CICERO AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR NORTH/SOUTH ELEVATIONS, 2ND - 3RD FLOORS, WINDOWS HAVE BEEN BRICKED IN AND COVERED UP - NO PERMIT. 354 N CICERO AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 1ST - 3RD FLOORS MISSING SMOKE DETECTORS - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 1ST - 3RD FLOORS MISSING CARBON MONOXIDE DETECTORS - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
UNDERSIDE STAIR 1HR FIRE RES UNDERSIDE OF EAST INTERIOR STAIRWELL 1ST TO 2ND FLOOR IS WOODEN - DANGEROUS. 354 N CICERO AVE COMPLAINT FAILED View
INTERIOR FINISH FIRERESISTANCE EAST ELEVATION LOBBY WALLS HAS 1/4 PLYWOOD COVERING ALL AREAS, MISSING FIRE SPREAD RATING. (15-8-370, 15-12-340) DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
FLAM LIQ TANK FRONTAGE CONSENT STORED GAS COMPRESSOR/SNOW BLOWER AT 3RD FLOORS - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
PROVIDE COMMERCIAL TO RESIDENTIAL ABOVE HAS BREECH IN CEILING WITH HOLES WHERE SECTIONS OF PIPES GO THROUGH. (13-56-280) 354 N CICERO AVE COMPLAINT FAILED View
REMOVE 1ST FLOOR REAR MARKED EXIT DOOR AT 31" WHICH IS BELOW 36" REQUIRED OPENING. (13-160-220) 354 N CICERO AVE COMPLAINT FAILED View
STOP ODORS RPR DFT SEWAGE SYS 2ND FLOOR OPEN 6" SEWER LINE. 354 N CICERO AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE DEFECTIVE AND UNDERSIZED POWER SERVICE TO 356 N. CICERO IMPROPERLY INSTALLED. RELOCATE METERS TO FIRST FLOOR ON EXTERIOR. INSTALL MINIMUM 600 AMP POWER SERVICE - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE DEFECTIVE AND UNDERSIZED POWER SERVICE TO 354 N. CICERO. RELOCATE METER TO EXTERIOR OF BUILDING AND INSTALL MINIMUM 400 AMP POWER SERVICE. 354 N CICERO AVE COMPLAINT FAILED View
RESTORE EXIT AND EM MAINTAIN EMERGENCY LIGHTING SYSTEM IN OPERABLE CONDITION. INSTALL BULBS TO EXIT SIGNS. INSTALL ADDITIONAL CHICAGO APPROVED EMERGENCY LIGHTS AND REMOVE ALL PLASTIC NON-APPROVED BATTERY LIGHTS IN COMMERCIAL SPACE 1ST FLOOR 354-56 N. CICERO. DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
INSTALL COVERS INSTALL COVERS TO ALL ELECTRICAL JUNCTION BOXES AND ELECTRICAL EQUIPMENT INCLUDING COMPRESSORS THROUGHOUT STORE 354-56 N. CICERO. EXPOSED WIRING - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
INSTALL COVERS INSTALL FILLERS TO ALL ELECTRICAL PANELS AT 354-56 N. CICERO. 354 N CICERO AVE COMPLAINT FAILED View
(18-27-110.26) MAINTAIN CLEARANCES TO ALL ELECTRICAL EQUIPMENT. 354 N CICERO AVE COMPLAINT FAILED View
(18-27-110.12) REMOVE ALL IMPROPER INSTALLATIONS OF LIGHT FIXTURES AND JUNCTION BOXES WITH MORE THAN 4 PENETRATIONS. ALL FIXTURES MUST BE FED THROUGH A JUNCTION BOX. DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED EXTENSION CORDS THROUGHOUT FIRST FLOOR AND INSTALL ADDITIONAL RECEPTACLES TO AVOID USE OF CORDS - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURES IN WALK-IN FREEZER 1ST FLOOR AND 2ND & 3RD FLOOR UNITS 354-356 N. CICERO. 354 N CICERO AVE COMPLAINT FAILED View
EXPOSED WIRING REMOVE ALL EXPOSED WIRING IN WALK-IN FREEZER AND ON EXTERIOR OF WALK-IN FREEZER - DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
(18-27-110.12) REMOVE ELECTRICAL PANEL TO 3RD FLOOR AT 354 N. CICERO IMPROPERLY INSTALLED. DANGEROUS CONDITION - PANEL IS OPEN. 354 N CICERO AVE COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PERMIT FOR LOW VOLTAGE SECURITY SYSTEM. 354 N CICERO AVE COMPLAINT FAILED View
(18-27-230.70)(A) METERS AND DISCONNECTING MEANS LOCATION 1ST FLOOR OR BASEMENT. DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
PRV RECEIVER 450# PSIG FOR ONE COPELAND 3 HP REMOTE REFRIGERATION UNIT LOCATED ON REAR MECH RM SERVING R.I.C. AND ONE COPELAND 6 HP REMOTE REFRIGERATION UNIT LOCATED OUTSIDE NORTH SERVING W.I.C. 354 N CICERO AVE PERIODIC FAILED View
PRV RECEIVER 450# PSIG FOR ONE COPELAND 3 HP REMOTE REFRIGERTATION LOCATED IN REAR MECH. ROOM SERVING REACH IN COOLER 354 N CICERO AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE REAR FULL OF JUNK AND DEBRIS ALL ELEVATION, STORAGE ON PORCH WASHER, GRILL, TABLE AND GARBAGE. 354 N CICERO AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT BATHROOM CEILING UNLEVEL PLASTER, NOT PAINTED 2ND. 354 N CICERO AVE COMPLAINT FAILED View
RATS THROUGHOUT RATS 354 N CICERO AVE COMPLAINT FAILED View
PRV RECEIVER 450# PSIG FOR ONE COPELAND 4 HP REMOTE REFRIGERTION UNIT LOCATED REAR MECH ROOM SERVING WALK IN COOLER 354 N CICERO AVE PERIODIC FAILED View
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. 354 N CICERO AVE COMPLAINT FAILED View
PROVIDE MECHANICAL ROOMS HAVE BREECH IN CEILING WITH EXPOSED LATH AT 2ND/3RD FLOORS. 34(13-196-172) DANGEROUS CONDITION. 354 N CICERO AVE COMPLAINT FAILED View
PROVIDE (18-28-801.2) FIRST FLOOR HANGING FURNACES ARE VENTED DIRECTLY THRU WALL THEN TERMINATE. FORCED AIR FURNACES AND HOT WATER HEATERS AT 2ND AND 3RD FLOORS HAVE UNWORKMANLIKE FLUE INSTALLATIONS, ONE HOT WATER HEATER AT 2ND FLOOR IS MISSING FLUE PIPE ENTIRELY - DANGEROUS AND HAZARDOUS. 354 N CICERO AVE COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRING IN OFFICE 2ND FLOOR SWITCHES - DANGEROUS AND HAZARDOUS. 354 N CICERO AVE COMPLAINT FAILED View
ROACHES THROUGHOUT ROACHES 354 N CICERO AVE COMPLAINT FAILED View