The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE OUTLETS | 2ND FLOOR UNIT DANGEROUS AND HAZARDOUS | 3535 W CARROLL AVE | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | REAR PORCH 2ND FLOOR | 3535 W CARROLL AVE | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | REAR PORCH, ELECTRICAL PERMIT REQUIRED | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | REAR PORCH | 3535 W CARROLL AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN HAS INCOMPLETE INFORMATION POSTED: MISSING MAILING ADDRESS. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | FRONT AND WEST ELEVATIONS/ VARIOUS WINDOWS - MISSING SCREENS. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
PARAPET | FRONT ELEVATION/ PARAPET WALL - WASHED OUT MORTAR.WEST ELEVATION/ PARAPET WALL - LOOSE AND SPALLING BRICKS WITH WASHED OUT MORTAR.PERMIT REQUIRED FOR MASONRY REPAIRS. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION/ LINTELS - RUSTED. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - NO ADDRESS POSTED. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION/ EXTERIOR WALL - WASHED OUT MORTAR. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR YARD GATE - DOUBLE KEY LOCKED. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY - MISSING SMOKE DETECTOR. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 2-STORY ENCLOSED WOOD PORCH/ COLUMNS - ROTTED; DOUBLE NOTCHED FOR FIRE CUTS AND HEADER JOISTS. BEAMS - ROTTED AND ONLY NAILED TO COLUMNS; PULLING OUT OF FIRE CUTS. 2ND FLOOR DECK - UNDERSIZED 2X6 DECK JOISTS SPAN 12 FEET. UNDERSIZED 2X6 ROOF JOISTS SPAN 12 FEET AND ROTTED. STRINGERS - ONLY NAILED TO COLUMNS AND POSTS. 2ND FLOOR RAILING - ONLY 29 INCHES HIGH. ALL RAILINGS - LOOSE AND PULLING; ONLY NAILED TO COLUMNS AND POSTS. TREADS, RISERS AND DECK BOARDS - ROTTED THROUGHOUT.PLANS AND PERMIT REQUIRED TO REPLACE PORCH. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT AND 1ST FLOOR - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. | 3535 W CARROLL AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | GFCI PROTECTION 2ND FLOOR BATH ROOM AND KITCHEN | 3535 W CARROLL AVE | COMPLAINT | PASSED | View |