Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBSTRUCTIONS IN EXIT WAY | REAR GATE PADLOCKED. EXTERIOR ENTRY DOOR - DOUBLE KEYED LOCK. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD, ACCUMULATION OF TRASH AN JUNK. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE ALL ELEVATIONS ROTTING WOOD. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND FLOOR APARTMENT, KITCHEN FLOOR, BROKEN AND MISSING TILE. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | ENCLOSED REAR PORCH JOISTS MISSING HANGERS AND TOE-NAILED. INADEQUATE BEAM TO COLUMN CONNECTIONS. COLUMN SPLICES MISSING. GUARDRAILS BELOW 42". GAP BETWEEN WALL AND STAIR STRINGS. DECKING WORN AND UNEVEN. OBTAIN PLANS AND PERMITS FOR PORCH REPAIRS. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | (18-29-102.3) (18-29-402.1) (18-29-402.1.1) | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR ENCLOSED STAIRS - BASEMENT TO 2ND FLOOR - 4X4 COLUMN OVER12' UNDER SIZED, GUARDRAILS UNDER 42" INCHES 34" INCHES, LOOSE TREADS, UNEVEN TREAD HEIGHTS, PLYWOOD DECKING AT LANDINGS, TREADS UNDER 10" INCHES, MISSING JOIST HANGERS, CANTILEVERED FLOOR JOIST AT 2ND FLOOR LANDING UNSUPPORTED, NO TOP RAILS AT HANDRAILS. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | WOODEN WALLS AT STAIRWAY ENCLOSURE. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
UNDERSIDE STAIR 1HR FIRE RES | STAIR UNDERSIDE UNPROTECTED. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
FOLLOW APPROVED PLANS | STAIRS NOT BUILT TO PLANS. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 7106 S EGGLESTON AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 7106 S EGGLESTON AVE | COMPLAINT | CLOSED | View | |
STOP LEAKING WATER | (18-29-1023) 2ND FL KITCHEN SINK | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 2ND FLOOR APARTMENT, REAR DOOR, BROKEN GLASS. | 7106 S EGGLESTON AVE | COMPLAINT | FAILED | View |