Chicago Building Violations Data: 64 Violations
Violation Inspector Comments Address Category Status View
PLANS & PERMITS REQ - CONTRCTR EXTENDED REAR REPLACING STAIR SYSTEM 1ST TO 3RD FLOORS WITH NEW LUMBER. SEC. 13-32-010; 13-32-040; 13-40-010; 13-40-020 7737 S COLFAX AVE COMPLAINT FAILED View
ARRANGE FOR REINSPECTION REGAR STOP ALL WORK UNTIL PERMIT IS OBTAINED. SEC. 13-12-080 7737 S COLFAX AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE 3RD FLR.WINDOW AIR=SEEPAGE THRU FRAMES. 7737 S COLFAX AVE COMPLAINT CLOSED View
SAFE WORKING CONDITIONS 3RD FLR.APARTMENT FURNACE BROKEN. 7737 S COLFAX AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS 3RD FLR.APARTMENT, NO SMOKE DETECTOR. 7737 S COLFAX AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID 3RD FLR.APARTMENT, NO CARBON MONOXIDE. 7737 S COLFAX AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID MISSING 3RD FLOOR APARTMENT 7737 S COLFAX AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS 3RD FLOOR APARTMENT MISSING THERMOSTAT 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 3RD FLOOR APARTMENT NO SMOKE DETECTOR 7737 S COLFAX AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S ID SIGN N NOT POSTED. 7737 S COLFAX AVE COMPLAINT FAILED View
REPLACE D&H PORCH COLUMNS SET ON CONCRETE SLAB- FOUNDATION STATUS UNKNOWN. COLUMNS BUTT-JOINED. COLUMN SPLICE 12" WITH 2 BOLTS ONLY. RIM JOISTS AND DECK JOISTS AT 2ND AND 3RD FLOOR DETACHED AND COLLAPSING (D&H). DECKING ROTTEN 1ST THRU 3RD FLOOR (D&H). RIM JOIST, DECK JOISTS, 36" RAIL SECTIONS, LEDGER BEAM, STRINGERS ALL ATTACHED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. PORCH POSTED. REAR PORCH - REPLACED - PERMIT NOT AVAILABLE DURING INSPECTION - SMF BL290542 7737 S COLFAX AVE COMPLAINT FAILED View
REPLACE D&H PORCH COLUMNS SET ON CONCRETE SLAB- FOUNDATION STATUS UNKNOWN. COLUMNS BUTT-JOINED. COLUMN SPLICE 12" WITH 2 BOLTS ONLY. RIM JOISTS AND DECK JOISTS AT 2ND AND 3RD FLOOR DETACHED AND COLLAPSING (D&H). DECKING ROTTEN 1ST THRU 3RD FLOOR (D&H). RIM JOIST, DECK JOISTS, 36" RAIL SECTIONS, LEDGER BEAM, STRINGERS ALL ATTACHED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. PORCH POSTED. REAR PORCH - REPLACED - PERMIT NOT AVAILABLE DURING INSPECTION - SMF BL290542; 7737 S COLFAX AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 2ND AND 3RD FLOOR UNITS MISSING PEEP HOLES 7737 S COLFAX AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR 1ST, 2ND, 3RD FLOOR UNITS FURNACE INSTALLED IN ALL UNITS NO PERMIT ON FILE 7737 S COLFAX AVE COMPLAINT FAILED View
FOUNDATION FOR FURNACE/BOILER 1ST, 2ND, 3RD FLOOR UNIT NO METAL PLATES UNDER ALL THERE UNITS FURNACE 7737 S COLFAX AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY NORTH SERVICE WALK BROKEN 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH MISSING ROOF HATCH COVER 7737 S COLFAX AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS REAR AT GRADE METER BOX MISSING COVER DANGEROUS 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRS BASEMENT TO GRADE MISSING HANDRAIL 1ST TO 2ND BROKEN TREADS 7737 S COLFAX AVE COMPLAINT FAILED View
MAINTAIN WINDOW 2ND AND 3RD FLOOR FRONT DOOR FRAME BROKEN 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR DOOR, INT. 3RD FLOOR FRONT DOOR BUSTED, ALSO MISSING DOOR ON 3RD FLOOR FURNACE FROM MISSING DOOR 7737 S COLFAX AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; 7737 S COLFAX AVE COMPLAINT FAILED View
NO POSTED ADDRESS BUILDING ADDRESS - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS NORTH ELEVATION /BASEMENT GLASS BLOCK WINDOW - NOT INFILLED AT ARCH [OPEN TO BASEMENT]; GAP, AIR SEEPAGE; 7737 S COLFAX AVE COMPLAINT PASSED View
STOP ODORS RPR DFT SEWAGE SYS BASEMENT [VIEW THROUGH NORTH BASEMENT WINDOW [OPENING AT ARCH] /OBNOXIOUS ODOR - STANDING SEWER WATER; 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ELEVATION /EXTERIOR DOOR HARDWARE - MISSING; 7737 S COLFAX AVE COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT BASEMENT [VIEW THROUGH NORTH BASEMENT WINDOW [OPENING AT ARCH] /STANDING SEWER WATER; 7737 S COLFAX AVE COMPLAINT FAILED View
ABANDONED REFRIGERATOR REAR YARD [AT BASEMENT DOOR] 2 ABANDONED REFRIGERATORS - [DOORS ATTACHED]; 7737 S COLFAX AVE COMPLAINT FAILED View
CHIMNEY CAPPING NORTH ELEVATION /CHIMNEY CAPPING - MISSING; 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR COPING SOUTH ELEVATION /COPING - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR GUTTER REAR ELEVATION /ROOF GUTTER - BROKEN AT GRADE; 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR DOOR HARDWARE FRONT INTERIOR FOYER DOOR /CLOSER - MISSING;3RD. FL. APT. /FURNICE ROOM DOOR VENT - MISSING; 7737 S COLFAX AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT 3RD. FL. APT. /KITCHEN CEILING - PEELING PAINT; 7737 S COLFAX AVE COMPLAINT PASSED View
REPLACE DEFECTIVE PLBG FIXTURE 3RD. FL. APT. /BATHTUB - PORCELAIN FINISH WORN-OUT; 7737 S COLFAX AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS 3RD. FL. APT. /SMOKE DETECTOR - MISSING; 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS FRONT STAIRWELL /SMOKE DETECTOR ¿ OUT OF SERVICE, WITH LOW BATTERY; 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 3 STORY WOOD PORCH WITH ROOF;STAIRS /TREADS -CRACKED, BROKEN; LANDING BETWEEN 1ST. AND 3RD. FL. - PORCH UNSTABLE, PULLING, SWAYING;RAILINGS /GUARD RAILING SECTIONS [GRADE TO BASEMENT] - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS [GRADE TO 1ST. FL.] - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; 7737 S COLFAX AVE COMPLAINT PASSED View
STOP ODORS RPR DFT SEWAGE SYS BASEMENT [VIEW THROUGH NORTH BASEMENT WINDOW [OPENING AT ARCH] /OBNOXIOUS ODOR - STANDING SEWER WATER; 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR FRONT ELEVATION /EXTERIOR DOOR - BROKEN PANE, OFF HINGES; 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ELEVATION /EXTERIOR DOOR HARDWARE - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
REMOVE STAGNANT WATER BSMT BASEMENT [VIEW THROUGH NORTH BASEMENT WINDOW [OPENING AT ARCH] /STANDING SEWER WATER; 7737 S COLFAX AVE COMPLAINT PASSED View
ABANDONED REFRIGERATOR REAR YARD [AT BASEMENT DOOR] 2 ABANDONED REFRIGERATORS - [DOORS ATTACHED]; 7737 S COLFAX AVE COMPLAINT PASSED View
PROVID SELF CLSING SCREEN DVCE REAR ELEVATION /SCREEN DOORS - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR GUTTER REAR ELEVATION /ROOF GUTTER - BROKEN AT GRADE; 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR DOOR HARDWARE FRONT INTERIOR FOYER DOOR /CLOSER - MISSING;3RD. FL. APT. /FURNICE ROOM DOOR VENT - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS 3RD. FL. APT. /SMOKE DETECTOR - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
CHIMNEY CAPPING NORTH ELEVATION /CHIMNEY CAPPING - MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID APT 3 / CARBON MONOXIDE DETECTOR - OUT OF SERVICE AT TIME OF INSPECTION. 7737 S COLFAX AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS APT. 3 / SMOKE DETECTOR - MISSING. 7737 S COLFAX AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE APT. 3 - USING STOVE AS HEATING DEVICE. 7737 S COLFAX AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE 3RD FLR.TENANT USING STOVE FOR HEAT. 7737 S COLFAX AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING /MOST APTS. ¿ NO RESPONSE. UNABLE TO VERIFY DETECTORS, AND CONDITIONS. 7737 S COLFAX AVE COMPLAINT PASSED View
RATS REAR YARD [AT NORTH SCREEN FENCE] /RAT BORROWS. 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM FRONT ELEVATION [GRADE TO 3RD. FL.] /INTERIOR STAIR WELL TREADS - CRACKED, LOOSE. 7737 S COLFAX AVE COMPLAINT PASSED View
REPAIR/REPLACE SMOKE DETECTORS 2ND. FL. APT. /SMOKE DETECTOR - OUT OF SERVICE, WITH MISSING BATTERY. 7737 S COLFAX AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID 2ND. FL. APT. /CARBON MONOXIDE DETECTOR - OUT OF SERVICE, WITH MISSING BATTERY. 7737 S COLFAX AVE COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY 2ND. FL. APT. /FRONT ENTRY DOOR - BURGLAR GATE. 7737 S COLFAX AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. 7737 S COLFAX AVE COMPLAINT FAILED View
PARAPET WEST AND SOUTH PARAPET WALL LOOSE BRICKS 7737 S COLFAX AVE COMPLAINT FAILED View
PROVID SELF CLSING SCREEN DVCE REAR ELEVATION /SCREEN DOORS - MISSING; 7737 S COLFAX AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT ELEVATION /EXTERIOR DOOR - BROKEN PANE, OFF HINGES; 7737 S COLFAX AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; 7737 S COLFAX AVE COMPLAINT PASSED View
HEAT UNIT ADEQUATELY 3RD FLR.NO HEAT 53DG. 7737 S COLFAX AVE COMPLAINT CLOSED View
REPAIR DOOR, INT. STAIRWELL FOYER DOOR MISSING 7737 S COLFAX AVE COMPLAINT FAILED View