Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:03 PM
PIN: 20074070260000
Property Address: 5118 S ASHLAND AVE
City - Zip: CHICAGO - 60609
2023 Property Class: 212
2023 Township: 72 - Lake
2023 Neighborhood: 72091
2023 Tax District: 72094
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 20 Violations
Violation Inspector Comments Address Category Status View
POST OWNER NAME OF VACNT BLDG VIOLATION CLOSED PER PCR 1180 5118 S ASHLAND AVE COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 5118 S ASHLAND AVE COMPLAINT CLOSED View
WATCHMAN 5118 S ASHLAND AVE COMPLAINT CLOSED View
OBTAIN OR POST PERMIT 5118 S ASHLAND AVE COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 5118 S ASHLAND AVE COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 5118 S ASHLAND AVE COMPLAINT CLOSED View
PARAPET PARAPET NORTH AND SOUTH ELEVATION SPALLED CONCRETE (SKIM COAT APPLICATION) OVER WASHED OUT MORTAR JOINTS. 14X-3-303.6 5118 S ASHLAND AVE COMPLAINT FAILED View
POST OWNER INFO ON ABDN BLDG 5118 S ASHLAND AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN ASSEMBLY BUILDING MISSING CARBON MONOXIDE DETECTORS. 14X-1-103.2 5118 S ASHLAND AVE COMPLAINT FAILED View
CHIMNEY CHIMNEY SPALLED CONCRETE AND WASHED OUT MORTAR. 14X-3-303.1. 5118 S ASHLAND AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALLS FRONT FACE BRICK, NOT LEVEL WAVY AT SURFACE, FRACTURES AT FACE BRICK AND STRUCTURE, NORTH AND SOUTH ELEVATIONS SPALLED CONCRETE. 14X-3-303.1.1 5118 S ASHLAND AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BUILDING MISSING SMOKE DETECTORS IN MULTIPLE LOCATIONS. 14X-1-103.2 5118 S ASHLAND AVE COMPLAINT FAILED View
REPAIR FLOOR INTERIOR 1ST AND 2ND FLOOR FLOORS UNEVEN AND DEFLECT UNDER LOAD. (ADDRESS DEFECT IN PLANS AND PERMIT) 14X-3-304.4 5118 S ASHLAND AVE COMPLAINT FAILED View
MIXED OCCUPANCY SEPARATION 1ST FLOOR EXSPOSED JOIST, MISSING FIRE SEPERATION. (INCLUDE DETAIL IN PLANS WITH PERMIT) 14B-508. 5118 S ASHLAND AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT EXSPOSED JOIST. MISSING DRYWALL/ PLASTER, COMPROMISED FIRE SEPERATION. (PROVIDE DETAIL IN PLANS AND PERMIT. 14B-5-508 5118 S ASHLAND AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXURES (INCLUDING PLUMBING , ELECTRIC, AND HVAC) INSTALLED IN THE BUILDING WITH-OUT A PERMIT. 14A-4-401. 5118 S ASHLAND AVE COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK ENTIRE BUILDING - FRAME REAR ADDTION, INSUFFIENT, BUILDING HAD SEVERE FIRE DAMAGE PRE 2016 NO PLANS OR PERMIT FOR REPAIRS. SEVERE STRUCTURAL ISSUES; BASEMENT DAMAGED JOIST, TEMPORARY BEAMS AND COLUMNS, CONCRETE, AND WOOD BLOCKS AS FOOTING; FLOORS DEFLECT UNDER LOAD; STAIRS SYSTEMS UNSTABLE; EXTERIOR WALLS REPAIRS INSUFFICIENT; PLANS AND PERMIT WITH STRUCTURAL REQUIRED. 14X-3-303.1.1 5118 S ASHLAND AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, NONRESDNTL BUILDING MISSING TAGGED FIRE EXSTINGUISHERS WITH SIGNAGE. 14X-5-504.5 5118 S ASHLAND AVE COMPLAINT FAILED View
WORK NOT ALLOWED EXTERIOR METAL FENCE OVER 5' REDUCE HEIGHT, OR PROVIDE PERMIT. 14A-4-404.7 5118 S ASHLAND AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BUILDING - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BUILDING. MUST ADDRESS STRUCTURE, ADDITION, MECHANICALS, AND USE OF BUILDING. 14A-4-401.1 5118 S ASHLAND AVE COMPLAINT FAILED View