Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | SR#07-00694134- HAND AND GUARDRAILS ARE LOOSE AND RUSTED. GUARDRAILS ARE ONLY 30 INCHES IN HEIGHT AND PICKETS ARE SPACED 5-1/2 INCHES APART. PERMIT IS REQUIRED FOR REPAIRS. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | FRONT BALCONY BROKEN PICKETS IMPROPER CONNECTIONS MOST MEMBERS ARE TOE NAILED TOGETHER AND ARE SEPERATING AT THE CONNECTIONS WITH LOOSE NAILS. PERMIT IS REQUIRED FOR REPAIRS. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | MOST WINDOWS WITH PEELING PAINT. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | REAR EAVES MISSING SECTION AND LOOSE SECTION OF ALUMINUM VENEER. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH AS VIEWED FROM THE ADJACENT PROPERTY COLUMNS ARE RESTED ON CONCRETE BASE, FOUNDATION STATUS IS UNKNOWN. THE NORTH BASE IS SPALLING. THERE IS NO POST TO SUPPORT THE STAIRS ABOVE GRADE LEVEL. STRINGERS ARE ONLY TOE NAILED INTO THE BUILDING. GUARDRAIL AT 1ST LANDING IS MISSING PICKETS. PICKETS ARE SPACED GREATER THAN 4 INCHES. SEVERAL MEMBERS ARE ROTTED, IMPROPER CONNECTIONS MOST MEMBERS ARE TOR NAILED TOGETHER AND ARE SEPERATING AT THE CONNECTIONS. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS OR REPLACEMENT. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | DOGS ARE CHEWING THRU DAMAGING THE FENCE BELONGING TO THE ADJACENT PROPERTY AT 5840. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT REVISED PLANS THAT SHOW NEW FOUNDATION FOR REAR 8 X 20 TWO STORY FRAME ADDITON PLUS PROCH | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | DETERMINE DAMAGED STRUCTURE FRACTURED FOUNDATION AND KNEE WALL | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
STOP WORK UNITL PERMIT IS OBTAINED 13-12-080 13-320-35 | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View | |
PERMIT REQUIRED - CONTRACTOR | SIDE AND REAR YARD - 78" FENCE; NO PERMIT OBTAINED | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | PERMITS #100237832, ISSUED 5/21/2009 AND #100225623, ISSUED 3/10/2008 FOR "RENOVATION OF PROJECT: 'REAR ADDITION AND REMODELING OF EXISTING SINGLE FAMILY HOUSE'" AND PERMIT ##100362159, ISSUED 9/8/2010 FOR "GARAGE" - NEVER FINALIZED. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS (IF ANY), BASEMENT, REAR PREMISES, AND REAR PORCH (IF ANY). UNVERIFIED DETECTORS AND OCCUPANCY. | 5838 S OAK PARK AVE | COMPLAINT | FAILED | View |