The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN WINDOW | MANY DAMAGED WINDOW FRAMES THRU-OUT ALL ELEVATIONS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | A.) BRICK ADD ON, 2 STORY SECTION, MUCH BRICK MOVEMENT ON ALL WINDOWS ABOVE LINTELS, AT EAST WALL SOME BULGING SHOWING WITH A STRESS CRACK FROM 1ST TO 2ND FLOOR, OTHER AREAS WITH STRESS FRACTURES; B.) FRAME SECTION OF MAIN HOUSE THERE IS A MISSING SECTION OF SIDING ON REAR GABLE, MANY OTHER AREAS MISSING CORNER PIECES OF THE SIDING | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | THERE IS MOVEMENT ON THE EAST AND NORTH CORNER OF THE PARAPET WALLS WITH BULGING BRICKS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | THERE ARE BROKEN PANES AT 1ST AND 2ND REAR, 2 WEST ON SOUTH BAY FRAME HOUSE SECTION. ON BRICK SECTION 2ND SOUTH OVER SIDE ENTRANCE, 1ST AND 2ND FLOOR EAST | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | WOOD BALCONY ON BRICK SECTION, 2ND FLOOR SOUTH ALL WOOD IS ROTTED, LOW GUARD RAILS, MISSING JOIST HANGERS, DECK IS PULLING AWAY FROM WALL, HLED UP ON 2 2X4 KICKERS FOR SUPPORT | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | MANY WINDOWS THRU-OUT ALL ELEVATIONS MISSING PUTTY | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | MANY DAMAGED WINDOW SASHES THRU-OUT ALL ELEVATIONS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | DAMAGED DOORS AND FRAME ON EAST ELEVATION 1ST FLOOR FRENCH DOORS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | A.) SOUTH ELEVATION ENTRY STAIRS MISSING JOIST HANGERS, LOW GUARD AND HAND RAILS, LEDGER BOARD NAILED TO WALL | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT WOOD ENTRY PORCH 23X10 MUCH ROTTED WOOD ON ALL COMPONENTS, LOW GUARD AND HAND RAILS, NORTH SECTION OF GUARD RAIL HAS FALLEN OFF, FRONT STEPS ARE FALLING DOWN, LIMESTONE SUPPORT COLUMNS ARE LEANING FORWARD, BRACING HAS BEEN INSTALLED UNDER THE DECK FOR SUPPORT-DANGEROUS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
CHIMNEY | LARGE SOUTH CHIMNEY HAS OPEN MORTAR JOINTS WITH LIMESTONE CAP FALLING APART, NORTH CHIMNEY MISSING CAP | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | GABLE PEAKS ON ALL ELEVATIONS HAVE DAMAGED EAVES | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | WEST NORTH, BAY ROOF, IS FALLING APART WITH ROOF DECK RAILINGS REMOVED | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | REAR GARAGE WITH SIDE ATTIC ACCESS, ALL SASHES AND WINDOW FRAMES FALLING APART, GRADE AND ATTIC ENTRY DOORS FALLING APART, NORTH ENTRY STEEL STAIRS RUSTED AND FALLING APART, ROOF ON BUILDING IS FALLING APART WITH SHEETING EXPOSED, SECTIONS CAVING IN, SHINGLES AND SHEETING FALLING APART, EAVES ALL WOOD ROTTED-DANGEROUS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | AUTO IN YARD, HIGH WEEDS, CONCRETE DRIVEWAY IS FALLING APART | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | PLANS AND PERMITS NECESSARY TO MAKE ALL REPAIRS ON BUILDING WITH MANY VIOLATIONS | 4853 S KIMBARK AVE | COMPLAINT | FAILED | View |