Last Modification Date: 2024-08-30 @ 2:16 PM
PIN: 20363170010000
Property Address: 1705 E 85TH ST
City - Zip: CHICAGO - 60617
2023 Property Class: 314
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70080
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 8 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS 1705 / APT 1 / SMOKE DETECTOR - MISSING. 1705 E 85TH ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION / EXTERIOR WALL - MASONRY FRACTURES WITH WASHED OUT MORTAR. LIME STONES ABOVE 2ND FLOOR WINDOWS ARE LOOSE AND BULGING OUTWARD. SOME APPEAR TO BE ON THE VERGE OF FALLING TO THE GROUND ( DANGEROUS AND HAZARDOUS ). PERMIT REUIRED FOR ALL MASONRY REPAIRS. 1705 E 85TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF MOST APTS AND BASEMENTS - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 1705 E 85TH ST COMPLAINT FAILED View
PARAPET NORTH ELEVATION / PARAPET - WASHED OUT MORTAR. 1705 E 85TH ST COMPLAINT FAILED View
REPAIR LINTELS NORTH ELEVATION / LINTELS - RUSTED, SAGGING AND DETERIORATED. SOME ARE COVERED WITH HEAVY CAULING TO HIDE DEFICIENCIES. WEST LINTELS ARE COVERED WITH CAPPING, UNABLE TO VERIFY LINTEL CONDITIONS. PLANS AND PERMIT REQUIRED FOR LINTEL REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. 1705 E 85TH ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 1701 AND 1705 / 1ST FLOOR APTS. / BATHROOM CEILINGS AND WALLS - WATER DAMAGED WITH MISSING PLASTER. 1705 E 85TH ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR ELEVATION / 2 2 STORY WOOD PORCHES / 8509 / DOUBLE WOOD BEAM - ROTING AND DETERIORATED. LEDGER BOARDS - FASNTENED WITH NAILS ONLY. STRINGER - ROTTIN AND DETERIORATED. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. 4X4 SUPPORT POST - NOTCHED AROUND END BEAM AND FASTENED WITH NAILS ONLY. 1701 - 05 / 2 STORY WOOD PORCH / LEDGER BOARDS - FASTENED WITH NAILS ONLY. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. TOP RAILS - ROTTING AND DETERIORATED. TREADS - LOOSE WITH POPPED NAILS. PLANS AND PERMIT REQUIRED FOR ALL PORCH REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. 1705 E 85TH ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 1705 / APT 1 / CARBON MONOXIDE DETECTOR - MISSING. 1705 E 85TH ST COMPLAINT FAILED View