Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 12:05 PM
PIN: 16054140340000
Property Address: 5648 W AUGUSTA BLVD
City - Zip: CHICAGO - 60651
2023 Property Class: 202
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR SOUTH WOOD STAIRS HAVE RISERS VARY 5", 7", 10". NORTH STAIRS GRADE TO BASEMENT MISSING GUARD/HANDRAILS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
INSTALL SMOKE DETECTORS 1ST FLOOR/2ND FLOOR MISSING SMOKE DETECTORS - DANGEROUS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
CARB MONOX DETECT IN RESID 1ST FLOOR/2ND FLOOR MISSING CARBON MONOXIDE DETECTORS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR NORTH ELEVATION HAS WOOD DECK CONSTRUCTED WITHOUT PLANS/PERMITS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
REPAIR/REPLACE SMOKE DETECTORS BASEMENT HAS NON-WORKING SMOKE DETECTOR - DANGEROUS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
REPAIR FLOOR 2ND FLOOR HALLWAY FLOOR HAS DEFLECTION AND IS DROPPING OUT OF LEVEL - DANGEROUS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM NORTH INTERIOR STAIRS GRADE TO BASEMENT MISSING HANDRAIL. STAIR LANDING SUPPORTED BY 2X4. STRINGERS ARE CONSTRUCTED FROM 3/4 STOCK. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
BLOCKED FIRE DOOR EXTREME AMOUNT OF CONSTRUCTION, TOOLS, BIKES, COMPRESSORS AND OTHER MERCHANDISE CAUSING EGRESS PROBLEMS IN BASEMENT AND 1ST FLOORS. THIS CAUSES A DANGEROUS AND HAZARDOUS CONDITION TO OCCUPANTS AND FIRST RESPONDERS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
REPAIR FLOOR 3"X12" CENTER BEAM HAS LARGE NOTCH REMOVED TO ACCOMMODATE HVAC DUCT AND 5 2"X8" FLOOR JOIST ARE ROTTED AND SISTERED WITH 2"X8"'S - DANGEROUS. CEILING HAS A TYVEK MATERIAL STAPLED TO CEILING/FLOOR JOIST. ALL MATERIAL NEED TO BE REMOVED TO SEE EXTENT OF CEILING/FLOOR STRUCTURE. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR PLANS/PERMITS ARE REQUIRED FOR SCOPE OF REPAIRS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
SUBMIT STRUCT. ENG. RPT (INT.) AN INTERIOR STRUCTURAL ENGINEER'S REPORT IS REQUIRED FOR BEAM AND FLOOR JOISTS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
WORK NOT ALLOWED STEEL/WOOD PICKET FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY SERVICE WALK HAS BROKEN CONCRETE CAUSING A TRIP HAZARD. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
REMOVE UNUSED OIL DRUMS/TANKS STORED COMPRESSED GAS TANKS, FUEL, PROPANE IN YARD AND GARAGE. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED EXTENSION CORDS AND POWER STRIPS THROUGHOUT 1ST FLOOR - DANGEROUS AND HAZARDOUS. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
UNAPPROVED CORDS REMOVE ROMEX FROM ELECTRICAL PANEL. 5648 W AUGUSTA BLVD COMPLAINT PASSED View
INSTALL GFCI'S TO WET LOCATIONS IN LAUNDRY ROOM AND INTERIOR AND EXTERIOR OF GARAGE. (18-27-210.8) 5648 W AUGUSTA BLVD COMPLAINT PASSED View