Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2300-04,2+3 +BASEMENT | 2300 W DEVON AVE | PERIODIC | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 2300 W DEVON AVE | COMPLAINT | FAILED | View | |
SUBMIT PLANS/GET VENT PERMIT | 2300 W DEVON AVE | COMPLAINT | FAILED | View | |
GIVE VENT OPENINGS % FL. AREA | PROVIDE VENTILATION OPENING 4% OF FLOOR AREA FOR AT 6410 N OAKLEY 18-28-403.3 | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
GIVE VENT OPENINGS % FL. AREA | PROVIDE EXHAUST VENTILATION 18-28-403.3 PHOTO STUDIO -1.2 CFM/SQ FT SALES-1 CFM/SQ FT TOILET- 2 CFM/SQ FT | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
PROVIDE OUTSIDE AIR SUPPLY | PROVIDE OUTSIDE SUPPLY AIR 18-28-403.3 MIN 100% CODE SUPPLY | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE LOCKING VOLUME DAMPERS IN FORCE WARM AIR RUN 18-28-603.15 | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
DUST SEPARATOR OUTSIDE OF BLDG | SEAL ALL JOINTS 18-28-603.8: 18-13-503.3.3.4.2 | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (1) PROVIDE COMBUSTION AIR 18-28-703.2 (2) FURNACE NOT ALLOWED IN BEDROOM-18-28-928.9.2 (3)PROVIDE FRONT CLEARANCE FOR FURNACE 18-28-919.9 (4) NO FLEX DUCT IN RESIDENTIAL UNIT 18-28-603.5.1 (5) MULTI STORY VENTING PROHIBITED 18-28-801.19 (6) PROVIDE PROPER PITCH TO FLUE 18-28-803.10.5 | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | REMOVE MORE THAN 5' OF FLEX DUCT FROM 1ST FL COMMERCIAL STORES | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAY OR REAR EXIT THAT USES ROOF AS EGRESS. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | 2300,2304,6410,/STORE FRONTS-VACANT AND SECURED. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | NORTH ELEVATION/WINDOW SILLS-WASHED OUT MORTAR. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION/2ND FLOOR-BROKEN GLASS PANE. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
OWNER OR LICENSED CONTRACTOR | 2300 W DEVON AVE | PERIODIC | CLOSED | View | |
VACANT BUILDING - REGISTER | 2300 W DEVON AVE | COMPLAINT | CLOSED | View | |
REPAIR EXTERIOR WALL | 2 EAST FRACTURES. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 640-1- REAR OF RESTAURANT WATER DAMAGED CEILING. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | 6406-1 REAR UNEVEN FLOORING. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR PLATFORM | WEST DECK SUPPORTS RUSTED . | 2300 W DEVON AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO COMMERCIAL SPACES, BASEMENT OR DWELLING UNITS. UNABLE TO VERIFY OCCUPANCY AND LIVING CONDITIONS. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BEEPING SMOKE DETECTOR ON 2ND AND 3RD COMMON HALLWAY. SMOKE DETECTOR HANGING BY WIRE ON 2ND FLOOR AT NORTH ELEVATION. DANGEROUS AND HAZARDOUS. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILING GRID ON 2ND AND 3RD FLOOR OF COMMON HALLWAY; BROKEN TILES, MISSING SECTIONS OF METAL GRID, WATER DAMAGED TILES. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
CARPETING | TORN CARPET CENTRAL INTERIOR STAIRS AT GRADE LEVEL WHICH CAUSES A TRIP HAZARD. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | BROKEN WINDOW SASH NORTH ELEVATION AT GRADE LEVEL. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH ELEVATION WINDOWS SILLS WITH WASHED OUT/MISSING MORTAR. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND WEST ELEVATION EXTERIOR WALL WITH WASHED OUT MORTAR AND SPALLING BRICK. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
REPAIR COPING | EAST AND SOUTH ELEVATION COPING STONES WITH WASHED OUT MORTAR JOINTS. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
IN THE DROP CEILINGS OF THE HALLWAYS THERE IS COMMUNICATION WIRING NOT PROPERLY SUPPORTED. THEY ARE NOT IN RING LOOPS OR BUNDLED PROPERLY. (18-27-300.4) | 2300 W DEVON AVE | COMPLAINT | FAILED | View | |
CONTINUITY OF RACEWAYS | PIPE NOT CONNECTED TO DISCONNECT FOR THE AIR CONDITIONING UNIT OUTSIDE SECOND FLOOR WEST ELEVATION. DANGEROUS AND HAZARDOUS. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | DEFECTIVE EXIT SIGN THIRD FLOOR LANDING CENTER. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | WIREMOLD COVER IS MISSING IN THE SECOND FLOOR HALLWAY SOUTH ELEVATION. | 2300 W DEVON AVE | COMPLAINT | FAILED | View |
LEAKING BOILER TUBES | #2 SELLERS FT #8982. | 2300 W DEVON AVE | PERIODIC | CLOSED | View |
OBTAIN PERMIT TO CORRECT VIOLATIONS. (13-12-360) | 2300 W DEVON AVE | COMPLAINT | FAILED | View | |
REPAIR INTERIOR WALLS/CEILING | 3RD FLOOR STAIRWELL / NEAR UNIT 306 / CEILING - ROOF HATCH AND CEILING, WATER DAMAGED AND OR STAINED WITH CHIPPED AND CRACKING PLASTER THROUGH OUT. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | STAIRWELL / ALL LEVELS / FIRE RATED DOORS - MISSING FIRE RATED TAGS | 2300 W DEVON AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | ALL LEVELS / FIRE EXTINGUISHERS - EXPIRED TAGS. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | ENTRY WAY AND 2ND FLOOR / HALLWAYS - OBSTRUCTIONS BLOCKING MEANS OF EGRESS. | 2300 W DEVON AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | STAIRWELL / NEAR UNIT 206 / FIRE RATED DOOR - SELF CLOSING DEVICE BROKEN. BROKEN HARDWARE. | 2300 W DEVON AVE | PERIODIC | FAILED | View |