The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP/REMOVE NUISANCE | REAR YARD - ABANDONED VEHICLE (EXPIRED PLATES 2015). | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / FRONT ENTRY DOOR-BROKEN PANE. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST AT 2 - BELOW WINDOW SILL - VERTICAL CRACKS; EAST ABOVE 3RD FLOOR - BRICKS LOOSE AND BULGING OUT. | 1340 N WESTERN AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED | REAR YARD / 10 FOOT ROLLING GATE,8 FOOT METAL FENCE BUILT.NO PERMIT OBTAINED. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD / TWO ABANDONED AUTO'S. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | EAST ELEVATION / 1ST FLOOR LINTELS-RUSTED. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
PARAPET | FRONT, NORTH AND SOUTH ELEVATIONS/ PARAPET WALLS - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID SIGN POSTED. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION / 4 CHIMNIES-MISSING CAPS. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
PARAPET | SOUTH ELEVATION / PARAPET WALL-WASHED OUT MORTAR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION / 2ND AND 3RD FLOOR STONE WINDOW SILLS-WASHED OUT MORTAR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
CHIMNEY HEIGHT | NORTH ELEVATION / 1ST FLOOR- 4 INCH FLUE PIPE STOPS AT 1ST FLOOR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / NO RESPONSE,UNVERIFIED DETECTORS,CONDITIONS,NO ENTRY TO REAR PORCH FOR 2018 ANNUAL INSPECTION. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID SIGN POSTED. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION / 4 CHIMNIES-MISSING CAPS. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / FRONT ENTRY DOOR-BROKEN PANE. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | EAST ELEVATION / 1ST FLOOR LINTELS-RUSTED. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION / 2ND AND 3RD FLOOR STONE WINDOW SILLS-WASHED OUT MORTAR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
CHIMNEY HEIGHT | NORTH ELEVATION / 1ST FLOOR- 4 INCH FLUE PIPE STOPS AT 1ST FLOOR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR GRADE TO BASEMENT EXTERIOR STAIRWAY - MISSING GUARD RAILS AT GRADE. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT TO GRADE EXTERIOR STAIRWAY - MISSING HAND RAIL. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR COPING | FRONT ELEVATION/ COPING STONES - WASHED OUT MORTAR. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR 3-STORY WOOD PORCH/ COLUMNS ARE RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. ALL COLUMNS (GRADE TO 3RD FL.) ARE TWISTED, BOWED AND LEANING OUT OF PLUMB; COLUMN HALF-LAP SPLICES ARE PULLING APART AT TWISTED COLUMNS. BEAMS - PULLING OUT OF COLUMN NOTCHES AND ONLY NAILED TO COLUMNS; BEAM NOTCHES AND COLUMN HALF LAP SPLICES ARE LOCATED AT SAME LOCATION ON COLUMN. UNDERSIZED 2X6 DECK JOISTS SPAN 10 TO 12 FEET AND ARE ONLY NAILED TO STAIR HEADERS. HEADER JOISTS ARE ONLY NAILED TO COLUMNS. GUARD RAILINGS ARE ONLY 39-40 INCHES HIGH. ALL RAILINGS ARE ONLY NAILED TO COLUMNS, POSTS AND EXTERIOR WALLS. MOST WOOD MEMBERS ARE DRY-ROTTED. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION AT 2 AND 3 - WINDOW SILLS - SHIFTING, OPEN JOINTS AND MISSING MORTAR. | 1340 N WESTERN AVE | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | SOUTH ELEVATION - THREE CHIMNEYS - MISSING CAPPING. | 1340 N WESTERN AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED | REAR ELEVATION/ 10 METAL FENCE WITH SLIDING GATE SYSTEM - CONSTRUCTED WITHOUT OBTAINING A PERMIT. (NEED ZONING APPROVAL BEFORE OBTAINING A PERMIT). SUBJECT TO FIELD INSPECTION AND APPROVAL BY IRON BUREAU.NORTH ELEVATION/ 7FT METAL FENCE - CONSTRUCTED WITHOUT OBTAINING A PERMIT. SUBJECT TO FIELD INSPECTION AND APPROVAL BY IRON BUREAU. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION/ EXTERIOR WALL - FRACTURED MASONRY, LOOSE AND BULGING BRICKS AT VARIOUS LOCATIONS.NORTH ELEVATION/ EXTERIOR WALL - LARGE FRACTURE FROM GRADE TO 2ND FLOOR NEAR EAST END.PERMIT REQUIRED FOR MASONRY REPAIRS. | 1340 N WESTERN AVE | PERIODIC | FAILED | View |
NO PERMIT WIRING | EVIDENCE OF FIRE, SIGN SAYS CONSTRUCTION AREA KEEP OUT. BUT NO PERMIT. SQUATERS IN THE BLDG, MAY BE TENANTS, BUT CLIMBING IN AND OUT OF WINDOWS. | 1340 N WESTERN AVE | COMPLAINT | FAILED | View |