Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REBUILD GARAGE OR SHED | REAR GARAGE BROKEN PANES,BROKEN GARAGE OVERHEAD DOOR | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | KITCHEN BROKEN PANES 2ND CRACK | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
RATS | RATS DROPPING THRU-OUT DWELLING | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST AND 2ND NO WORKING SMOKE DETECTORS | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST AND 2ND NO WORKING SMOKE DETECTOR | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OF BUILDING/ EXTERIOR STAIR - GRADE TO 1ST FL.6X6 COLUMNS ERECTED ON DIRT. 4X4 COLUMNS ERECTED ON SERVICE WALK.LEDGER BOARD NAILED TO WALL JOIST SAGGING. JOIST NAILED TO HEADER. GUARD RAILS AND STRINGERS NAILED ONLY TO COLUMNS ,HEADERS AND WALL GUARD RAILS 36 HIGH .GUARD RAILS WEAK AND SPAN 10FT PLANS AND PERMIT REQUIRED FOR REPAIRS TO PORCH. | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD PILES WOOD AND SIDING . | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR OF BUILDING/ EXTEIOR STAIRWELL- BASEMENT TO GRADE HAND RAIL MISSING. | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUH ELEVATION / EXTERIOR WALL - WASHED OUT MORTAR. | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT OF BUILDING / WOODEN FENCE - 45X6 FT PERMIT REQUIRED FOR FENCE. | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE ROOF AND WALLS COLLAPSE. PERMIT REQUIRED FOR REPAIRS TO GARAGE. GARAGE DANGEROUS AND HAZARDOUS | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | 1-STORY 12FT.X 12FT REAR FRAME ADDITION ERECTED.REMOVE ALL WORK ELECTRICAL AND VENTILATION FIXTURES INSTALLED WITHOUT PERMIT. | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE REAR ADDITION AND ALTERATIONS TO EXISTING BUILDING OR RESTORE THE BUILDING TO ORIGINAL CONDITIONS. | 7219 S WOLCOTT AVE | COMPLAINT | FAILED | View |