Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 11:22 PM
PIN: 20341090230000
Property Address: 8008 S PRAIRIE AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 203
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70111
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 7 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY ATTIC APT. - ROOM TEMPERATURE 57 DEGREES F. AT 11:39 AM.HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. 8008 S PRAIRIE AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS ATTIC - MISSING SMOKE DETECTORS. 8008 S PRAIRIE AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR REAR GRADE TO ATTIC EXTERIOR WOOD STAIRWAY/ COLUMNS ARE RESTING ON DIRT, FOUNDATION STATUS IS UNKNOWN. LEDGER BEAM FOR ATTIC LANDING IS ONLY NAILED TO FASCIA OF ROOF EAVE.ATTIC LANDING/ RIM JOISTS ARE ONLY NAILED TO COLUMNS AND MISSING INNER DECK JOISTS. ALL HEADERS ARE ONLY NAILED TO COLUMNS.STRINGERS - UPPER AND LOWER ENDS ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. TREADS AND RISERS - WEAK, LOOSE WITH NAILS PULLING OUT.ALL RAILINGS - LOOSE, PULLING AND ONLY NAILED TO COLUMNS AND POSTS.ENTIRE STAIRCASE IS WEAK AND UNSTABLE WITH EXCESSIVE SWAYING.DANGEROUS AND HAZARDOUS CONDITIONS.PLANS AND PERMIT ARE REQUIRED TO REPLACE REAR GRADE TO ATTIC EXTERIOR STAIRWAY. 8008 S PRAIRIE AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE BUILDING TO THE ORIGINAL STATE. ATTIC HAS BEEN REMODELED WITH DORMERS INTO DWELLING UNIT WITHOUT PLANS AND A PERMIT.SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 8008 S PRAIRIE AVE COMPLAINT CLOSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE ATTIC WITHOUT A PERMIT. 8008 S PRAIRIE AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID ATTIC - MISSING CARBON MONOXIDE DETECTOR. 8008 S PRAIRIE AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE BUILDING TO THE ORIGINAL STATE. ATTIC HAS BEEN REMODELED WITH DORMERS INTO DWELLING UNIT WITHOUT PLANS AND A PERMIT.SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 8008 S PRAIRIE AVE COMPLAINT FAILED View