Chicago Building Violations Data: 235 Violations
Violation Inspector Comments Address Category Status View
REPAIR ROOF SOUTHWEST STAIRWELL 3RD FLOOR - ROOF LEAK. 2600 W 35TH ST COMPLAINT FAILED View
PARAPET NORTH PARAPET (WEST END) - LENING OUT.SOUTH PARAPET- SPALLING BRICKS AND ERODED MORTAR JOINTS.EAST PARAPET - STEP CRACKS. MASONRY PERMIT REQUIRED FOR REPAIRS. PLANS AND PERMIT ARE REQUIRED TO REPAIR EXTERIOR WALLS. 2600 W 35TH ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL 3 STORY FACTORY INDUSTRIAL USE BUILDING :WEST, SOUTH AND EAST ELEVATIONS - CONCRETE WALL COUMNS AND BEAMS - SPALLING, ERODED, CRACKED, EXPOSED REBAR AND POOR CRAFTMANSHIP REPAIRS MADE. EAST ELEVATION - ERODED MORTAR JOINTS AND SPALLING BRICKS.PLANS AND PERMIT ARE REQUIRED TO REPAIR BUILDING EXTERIOR WALLS. 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR EMERGENCY ALARM IN PASSENGER ELEVATOR. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A CERTIFICATE FRAME IN ALL ELEVATORS. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
GIVE VENT OPENINGS % FL. AREA 18-28-403.3 VENTILATION REQUIREMENTS PROVIDE MECHANICAL EXHAUST AT CUBIC FEET PER MINUTE TIMES FACTOR BASED IN USE NEED EXHAUST VENTILATION FOR DULCE LANIA WAREHOUSE 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR VIOLATIONS ON UNIT OR DECOMMISSION. UNIT RUNNING UPON ARRIVAL. RED TAGGED. DO NOT USE. 2600 W 35TH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA FINALIAZE PERMIT NO. 100782592 (CAR #2) (PREVIOUSLY CITED). REPAIR OR DECOMMISSION UNIT. 2600 W 35TH ST PERIODIC FAILED View
ARRANGE ANNUAL INSP. 2600 W 35TH ST PERIODIC FAILED View
NO ENTRY 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE ANNUAL INSP. 2600 W 35TH ST COMPLAINT FAILED View
NO ENTRY 2600 W 35TH ST PERIODIC FAILED View
FIRE EXTNGSHR REQ, RESDNTL WAREHOUSE- MOST FIRE EXTINGUISHERS MISSING. 2600 W 35TH ST COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG MOST FIRE EXTINGUISHERS- EXPIRED TAGS. 2600 W 35TH ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR NEW TRUCK DOCK DOOR CUT INTO WALL.NO PERMIT ON FILE. 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN EXIT SIGN ILLUMINATED EXIT SIGNS NOT ILLUMINATED. 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS2600 W. 1ST FLOOR LEVEL. UNVERIFIED COMPLAINT OF: " NO BATHROOM FACILITIES, NO BLEACHERS". 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY TO CHECK OCCUPANCY DETECTORS AND COMPLAINT OF MISSING EXIT SIGNS. 2600 W 35TH ST COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT OBTAIN PERMIT FOR /FURNACE REPLACEMENT ON THE 3RD FLR OFFICE SPACE FOR "POPPIS DOE" 2600 W 35TH ST COMPLAINT PASSED View
PROVIDE PROVIDE ADEQUATE HEAT THRU OUT BUILDING 4(5-4-270) 54-56 DEGREE'S THRU OUT THE CORRIDORS 11:15AM 2600 W 35TH ST COMPLAINT PASSED View
MAINT PLATFORM LIFT PROVIDE A CERTIFICATE FRAME FOR ALL PLATFORM LIFTS 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CLOSE OUT PERMIT NO. 100782592 (CAR #2) 2600 W 35TH ST PERIODIC FAILED View
NO PERMIT WIRING OBTAIN PERMIT FOR WIRING INSTALLED WITHOUT PERMIT IN FIRST FLOOR SPACE (POPPIES BAKERY) 2600 W 35TH ST COMPLAINT FAILED View
EXPOSED WIRING FIXTURES EXPOSED WIRING AT TRACK FIXTURE IN MAIN LOBBY 1ST FLOOR 2600 W 35TH ST COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE FIXTURE IN 1ST FLOOR REAR HALLWAY 2600 W 35TH ST COMPLAINT FAILED View
RESTORE EXIT AND EM RESTORE EXITS AND EM SYSTEM TO OPERABLE CONDITION 2600 W 35TH ST COMPLAINT FAILED View
UNAPPROVED EM REMOVE UNAPPROVED WIRING FROM EMERGENCY SYSTEM 2600 W 35TH ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH METAL STAIRWAY - RUSTED. 2600 W 35TH ST COMPLAINT CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A CERTIFICATE FRAME IN ALL ELEVATORS 2600 W 35TH ST PERIODIC FAILED View
POST CURRENT CERTIF PASS ELE 2600 W 35TH ST PERIODIC CLOSED View
POST CURRENT CERTIF FRT ELE 2600 W 35TH ST PERIODIC CLOSED View
POST CURRENT CERTIF PLAT LIFT 2600 W 35TH ST PERIODIC CLOSED View
TEST G & S FRT ELE 2600 W 35TH ST PERIODIC CLOSED View
OPEN TYPE VIOLATION 1. PERFORM PRESSURE RELIEF TEST DATE W/TAG WHEN COMPLETED. 18-30-010,13-20-120. EV016002. 2600 W 35TH ST PERIODIC CLOSED View
PRV HIGH SIDE FOR ONE TRANE 75 TON ROOFTOP UNIT WITH SIX COMPRESSORS LOCATED ON HIGH ROOF. ONE TRANE 75 TON ROOFTOP UNIT WITH TWO COMPRESSORS LOCATED ON ROOF 35TH ST. SIDE. ONE TRANE 40 TON ROOFTOP UNIT WITH FOUR COMPRESSORS LOCATED ON ROOF 35TH ST. SIDE. ONE TRANE 30 TON ROOFTOP UNIT WITH TWO COMPRESSORS LOCATED ON ROOF 35TH ST. SIDE NORTH. 2600 W 35TH ST PERIODIC FAILED View
OBTAIN REFRIGERATION PERMIT FOR ONE DAIKEN 20 TON A/C UNIT LOCATED ON WEST MID ROOF -R410A,TWO COMPRESSORS,AIR COOLED AND SELF CONTAINED. FOR TWO CENTURY REFRIGERATION UNITS LOCATED ON NORTH ROOF CENTER-15HP. EACH ,R-507 WITH 8"X 60"RECEIVER SERVING W-IN FRZR AND COOLER. FOR ONE KRACK / COPELAND 20 HP. COMPRESSOR LOCATED ON LOW ROOF NORTHWEST. R404A,AIR COOLED,REMOTE WITH 8" X 60" RECEIVER. FOR TWO CENTURY REFRIGERATION 15 HP. COMPRESSORS LOCATED ON LOW MID ROOF CENTER,R507,AIR COOLED,REMOTE WITH A 8" X 60" RECEIVER. FOR ONE CENTURY REFRIGERATION 10 HP. COMPRESSOR LOCATED ON LOW MID ROOF CENTER,R507,AIR COOLED,REMOTE,WITH 8" X 40" RECEIVER. FOR ONE CARRIER 40 TON A/C UNIT LOCATED AT GRADE NORTH OF ENTRANCE,R-410A,AIR COOLED,SELF CONTAINED WITH FOUR COMPRESSORS. 2600 W 35TH ST PERIODIC FAILED View
FIRE RESISTIVE SUPPORTS FOR ONE DAIKEN 20 TON ROOFTOP A/C UNIT LOCATED ON WEST MID ROOF. PROVIDE PROPER ROOF CURBS. UNIT IS CURRENTLY SITTING ON WOOD 6X6"S 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA BUILDING TO COORDINATE AN INSPECTION WITH THE CITY OF CHICAGO'S ELEVATOR BUREAU, TO IDENTIFY ALL ELEVATORS AND HOISTWAYS, BOTH RUNNING AND OUT OF SERVICE. TO DETERMINE IF THE IN COMPLIANCE OR REMOVED PROPERLY. 2600 W 35TH ST PERIODIC FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED OF WARM AIR HEATING SYSTEMS 2600 W 35TH ST COMPLAINT FAILED View
STOP NUISANCE TO EMPLOYEES 7-28-030 COMMON LAW AND STATUTORY NUISANCES 7-7-060 CONDITIONS DETRIMENTAL TO HEALTH PUBLIC NUISANCE 7-28-080 NUISANCE IN CONNECTION TO BUSINESS 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 8011) 13-196-75 HEAT REQUIRED MAINTAIN AT LEAST 68 DEGREE'S IN FACTORIES & WORKSHOPS OR OTHER PLACE OF EMPLOYMENT BLDG OWNERS OR PLANT OPERATORS MUST MAINTAIN MINIMUM REQUIRED TEMPERATURES BETWEEN 8:00AM-6"00PM FROM OCT 1 TO JUNE 1ST W/EXCEPTION TO SUNDAY'S & HOLIDAYS 311 NO HEAT COMPLAINT 58 DEGREE'S WORK AREAS 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ALL FREIGHT ELEVATORS, PROVIDE SAFETY EDGE OR SAFE HOISTWAY DOOR CLOSING (A17.3-2.6.5) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A CURRENT MAINTENANCE CONTROL PROGRAM FOR ALL ELEVATORS 2600 W 35TH ST PERIODIC FAILED View
MAINT PLATFORM LIFT BUILDING TO COORDINATE AN INSPECTION WITH THE CITY OF CHICAGO'S ELEVATOR BUREAU, TO IDENTIFY ALL PLATFORM LIFTS, BOTH RUNNING AND OUT OF SERVICE. TO DETERMINE IF THEY ARE IN COMPLIANCE OR REMOVED PROPERLY. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CLOSE OUT PERMIT NO. 100812324 (CAR #9) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CLOSE OUT PERMIT NO. 100812325 (CAR #10) 2600 W 35TH ST PERIODIC FAILED View
BLANK-TEXT MUST CITE CODE SECT FAILED TO USE MATERIALS HAVING A FIRE RESISTANCE OF AT LEAST 4 HOURS TO SEPARATE ASSEMBLY AND STORAGE OCCUPANCIES AT SECOND AN 3RD FLOOR.SECTION 13-56-280. 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED ARRANGE FOR COMPLETE PERMIT INSPECTION WHEN HEAT IS ON 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 8011) 13-196-750 HEAT REQUIRED MAINTAIN AT LEAST 68 DEGREE'S F IN PLACES OF EMPLOYMENT UNLESS WORKING CONDITIONS OR PROCESS REQUIRED OTHER TEMPERATURES 2600 W 35TH ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY ROOM TEMPERATURE ON 3RD FLOOR 50FT NORTH OF ELEVATOR IN CORRIDOR TEMPERATURE IS 58 DEGREE'S F 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA UNABLE TO GAIN ACCESS TO MACHINE ROOMS. CONTACT ELEVATOR BUREAU FOR INSPECTION. 312-743-3594 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR DIRECTIONAL LANTERNS AND PASSING GONG ON PASSENGER ELEVATOR. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE CERTIFICATE FRAME AND DISPLAY CURRENT CERTIFICATES IN ALL ELEVATORS 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE MAINTENANCE CONTROL PROGRAMS AND MAINTENANCE LOGS FOR ALL ELEVATORS 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE EMERGENCY TELEPHONES IN ELEVATORS. PROGRAM EMERGENCY PHONE TO A 24 HR ANSWERING SERVICE. 2600 W 35TH ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ACCESS TO INTERIOR FOR 2017 ANNUAL INSPECTION. CALL 312 743-0407 FOR INSPECTION. 2600 W 35TH ST PERIODIC FAILED View
REPAIR EXTERIOR STAIR FRONT AND REAR EXIT STAIRS--MISSING INTERMEDIATE HANDRAILS. REPAIR BROKEN HANDRAIL AT NORTHWEST EXIT STAIR. 2600 W 35TH ST PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH, SOUTH AND WEST ELEVATIONS--MAINLY ABOVE WINDOWS--LOOSE AND FRACTURED MORTAR AT VARIOUS LOCATIONS. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA OBTAIN PERMIT TO PROPERLY REMOVE FREIGHT CARS NOT IN USE. (2) FREIGHT ELEVATORS 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY SERVICE & MAINTAIN #8 FREIGHT ELEVATOR 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PERFORM CAT5 TEST LAST TEST 2006 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA DETERMINE CONDITION OF SAFETY GOVERNOR AND BUFFERS, BEFORE TEST. 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE EMERGENCY PHONE INSIDE ELEVATOR 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA RED TAG VIOLATION 00604-DISCONTINUE USE OF RUNNING FREIGHT WITHOUT HOISTWAY DOOR ON 2ND FLOOR LANDING 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE PROPER PULL-STRAPS ON GATE AND HOISTWAY DOORS (A17.3-2.6.6) 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE SAFETY EDGE OR SAFE HOISTWAY DOOR CLOSING. (A17.3-2.6.5) 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE THE LOADING CLASS PLATE INSIDE FREIGHT ALONG THE "NO PASSENGER" SIGNAGE.(A17.3-3.7.5) 2600 W 35TH ST PERIODIC CLOSED View
MAINTAIN OR REPAIR HYDRO ELEVA OBTAIN A CURRENT PASSENGER ELEVATOR CERTIFICATE AND POST INSIDE THE ELEVATOR. 2600 W 35TH ST PERIODIC CLOSED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE MECHANICAL VENTILATION OR WARM AIR HEATING SYSTEM FINAL INSPECTION WHEN WORK COMPLETED 13-12-100 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE PROVIDE A VENTILATION PERMIT THE LIGHTHOUSE BANQUET 3RD FLR CHICAGO CAFFE HALL LIFE, CHURCH MIDWEST BAKERY FIRST FL, BOXING GYMNASIUM OFFICES 2ND FLR 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE MECHANICAL VENTILATION WHEN WORK IS COMPLETED CODE 13-12-100 2600 W 35TH ST COMPLAINT FAILED View
STOP NUISANCE TO NEIGHBORS STOP NUISANCE TO NEIGHBORS 7-28-020 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE LICENSE INSP. ARRANGE LICENSE INSPECTION 13-176-310 2600 W 35TH ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PERMIT FOR THE CONVERSION OF THE FORMER CAMPBELL SOUP FACTORY TO A MULTIPLE COMMERCIAL MIXED USE TENANT COMPLEX NOW KNOWN AS THE CMP CHICAGO BUSINESS CENTER. THE BUILDING INCLUDES ABOUT 683,000 SQUARE FEET HOUSING ABOUT 15 BUSINESS. A CONSIDERABLE PORTION OF THE BUILDING IS VACANT SPACE. EXISTING CONFIGURATION IS HAPHAZARD COMPLEXION OF TENANT BUILDOUTS WITHOUT REGARD TO LIFE SAFETY REQUIREMENT AND ADEQUACY OF ELECTRICAL, PLUMBING AND HVAC SYSTEMS. 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE SUBMIT REPORT FROM LICENSED FIRE PROTECTION ENGINEER THAT CERTIFIES AUTOMATIC SPRINKLER SYSTEM IS ADEQUATE FOR CURRENT USE OF BUILDING THE SYSTEM WAS DESIGNED FOR AN OPEN PLAN MANUFACTURING FACILITY THE CURRENT USE AS A MULTIPLE TENANT COMPLEX OF VARYING OCCUPANCY TYPES HAS INTRODUCED A RADICALLY ALTERED FLOOR PLAN THAT MAY JEOPARDIZE THE CAPABILITY OF THE SYSTEM TO PROTECT OCCUPANTS AND CONTENTS 13-32-010,15-6-170,15-16-350 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE SUBMIT REPORT TO DEPARTMENT OF BUILDINGS FROM ACCREDITED TESTING SERVICE THAT PROVIDES ANALYSIS OF PIPE INSULATION MATERIAL AS OBSERVED AT VACANT PORTION OF THIRD FLOOR IF REPORT WILL DETAIL THE ABATEMENT PLAN 11-4-2150 THRU 11-4-2180 2600 W 35TH ST COMPLAINT FAILED View
CLASS B DOOR IN STAIRWELL 3RD FLR SOUTHWEST STAIR DOOR # 7 RUBS AGAINST FRAME 2600 W 35TH ST COMPLAINT FAILED View
HOLDOPEN DEVICE, STAIR 3+ FLRS 3RD FL SOUTHWEST STAIR DOOR AND HALLWAY DOOR BEING HELD OPEN WITH EXTENSION CORDS AND TELECOMMUNICATION CABLE 2ND FLOOR/TOWER 3 DOORS HELD OPEN WITH CABLE 3RD FLR/TOWER 6 DOORS HELD OPEN WITH CORD 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION EAST ELEVATION FOURTH FLOOR NO ENTRY UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY 2600 W 35TH ST COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG ALL FLOOR MULTIPLE LOCATIONS EXPIRED FIRE EXTINGUISHER TAGS 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN EXIT SIGN ILLUMINATED ALL FLOOR MULTIPLE LOCATIONS EXIT SIGNAGE OUT OF OPERATION 2600 W 35TH ST COMPLAINT FAILED View
INSTALL EXIT SIGN ALL FLOORS, MULTIPLE LOCATIONS MISSING EXIT SIGNAGE OBTAIN PERMIT FOR INSTALLATION 2600 W 35TH ST COMPLAINT FAILED View
ILLUMINATE PUBLIC STAIR/HALL ALL FLOOR, MULTIPLE LOCATIONS EXIT ILLUMINATION OUT OF OPERATION ALL FLOORS MULTIPLE LOCATIONS MISSING INTERIOR EXIT ILLUMINATION OBTAIN PERMIT FOR INSTALLATIONS 2600 W 35TH ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE NORTHEAST, SECTION OF 2ND & 3R FLOOR MULTIPLE LOCATIONS EXCESSIVE STORAGE AND DEBRIS INCLUDING CONSTRUCTION DEBRIS PROPANE TANK STORAGE, GAS FUELED GO KATS, DISCARDED INVENTORY.STOCKPILE OF DISCARDED OFFICE EQUIPMENT,CARDBOARD AND MATTRESS TIRE STORAGE, 1ST FLOOR, NORTHEAST SECTION (DURANGO LIFTS) STOCKPILE OF MATTRESSES 2600 W 35TH ST COMPLAINT FAILED View
1HR PUB.CORIDR NON-RES/SPRNKLD 3RD FLOOR NORTHWEST CORRIDOR ELECTRICAL ROOM MISSING DOOR CLOSER AND "B" LABEL DOOR 3RD FLOOR NORTHWEST CORRIDOR MENS RESTROOM BROKEN DOOR CLOSER 2600 W 35TH ST COMPLAINT FAILED View
CLASS B DOOR IN STAIRWELL ALL FLOORS MULTIPLE LOCATING MISSING D?OR BROKEN DOOR CLOSERS, MISSING AND OR BROKEN PANIC HARDWARE DOORS RUBBING AGAINST FRAME RUSTING DOORS 2600 W 35TH ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR ALL FLOORS MULTIPLE LOCATIONS SUBMIT PLANS AND OBTAIN PERMIT FOR BUILD OUT OF INTERIOR PARTITIONS FOR TENANT SPACES SCOPE OF WORK INCLUDES MECHANICAL ELECTRICAL AND PLUMBING MODIFICATIONS PLANS AND PERMIT SHOULD INDICATE CHANGE OF USE 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE PROVIDE 7'-0" HEAD ROOM CLEARANCE AT 2ND FLR NORTH DOOR ADJACENT TO HOW MASONRY OPENING STAIR HEAD ROOM REDUCED TO 6'-0" HEAD ROOM AT INTERMEDIATE LANDING FROM SECOND FLOOR TO FIRST 7'-0" HEAD ROOM REQUIRED PER 10(13-160-350) 2600 W 35TH ST COMPLAINT FAILED View
CLASS B DOOR IN STAIRWELL 3RD FLOOR CHICAGO CAFFE/WEST EVENT ROOM-NORTH WEST STAIR, MISSING 'B' DOORS AT LANDING 2600 W 35TH ST COMPLAINT FAILED View
2-HR HEATING PLANT ENCLOSURE 3RD FLR CHICAGO CAFFE/WEST EVENT ROOM THREE HEATING PLANTS MISSING ENCLOSURE. 3RD FLOOR CHICAGO CAFFE/EAST EVENT ROOM-TWO HEATING PLANTS MISSING ENCLOSURE 2ND FLOOR CHICAGO CAFFE/ EAST EVENT ROOM -TWO HEATING PLANS MISSING ENCLOSURE PERMIT REQUIRED FOR HEATING PLANT ENCLOSURES 2600 W 35TH ST COMPLAINT FAILED View
REPAIR DOOR HARDWARE 3RD FLOOR CHICAGO CAFFE/WEST ROOM -NORTHWEST DOORS MALFUNCTIONING HARDWARE, 3RD FLOOR CHICAGO CAFFE/ EAST ROOM MISSING PANIC HARDWARE 2600 W 35TH ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 3RD FLOOR CHICAGO CAFFEE.WEST AND EAST ROOMS SLIDE BOLTS AT EXIT DOORS 2600 W 35TH ST COMPLAINT FAILED View
INSUFFICIENT MEANS OF EGRESS 3RD FLOOR CHICAGO CAFFEE/EAST ROOM INSUFFICIENT NUMBER OF EXITS ONLY 1 LABELED EXIT FOR 5,000 SQ FT 2600 W 35TH ST COMPLAINT FAILED View
REPAIR DOOR HARDWARE 3RD FLOOR CHICAGO CAFFE/WEST ROOM NORTHWEST DOORS MALFUNCTION HARDWARE,3RD FLOOR CHICAGO CAFFEE/EAST ROOM -MISSING PANIC HARDWARE 2600 W 35TH ST COMPLAINT FAILED View
INSUFFICIENT MEANS OF EGRESS 3RD FLOOR CHICAGO CAFFEE/EAST RM INSUFFICIENT NUMBER OF EXITS, ONLY 1 LABELED EXIT FOR 5,000 SQ FT SPACE. NORTHWEST EXIT DOORS SWING AGAINST EGRESS TRAVEL NORTH EXIT PATH OBSTRUCTED BY DEBRIS AND STORAGE 2600 W 35TH ST COMPLAINT FAILED View
POST APPROVED OCCUPANCY CARD OBTAIN OCCUPANCY PLACARD FOR FIVE CHICAGO CAFFE EVENT SPACES ON SECOND AND THIRD FLOORS 2600 W 35TH ST COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL MISSING FIRE EXTINGUISHER AT CHICAGO CAFFE EVENT SPACES AND CHICAGO CAFFE AUXILIARY SPACES 2600 W 35TH ST COMPLAINT FAILED View
INTERIOR FINISH FIRERESISTANCE PROVIDE FLAMESPREAD DOCUMENTATION FOR DECORATIVE FABRIC THROUGHOUT CHICAGO CAFFE EVENT SPACES ON SECOND AND THIRD FLOOR 2600 W 35TH ST COMPLAINT FAILED View
DOOR SWING IN DIR. OF TRAVEL 2ND FLR CHICAGO CAFFE/EAST ROOM LABELED EGRESS DOOR SWINGS AGAINST EGRESS TRAVEL 2600 W 35TH ST COMPLAINT FAILED View
STOP LEAKING WATER 2ND FLR CHICAGO.EAST ROOM LEAKING WATER FROM 3RD FLOOR PLUMBING 2600 W 35TH ST COMPLAINT FAILED View
KEEP FIXTUR CLEAN AND SANITARY 3RD FLOOR CHICAGO CAFFE/MENS .WOMENS RESTROOM UNSANITARY CONDITIONS 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE ANNUAL INSP. 13-20-290,13-20-020 INSPECTION REQUIRED. MAKE ARRANGEMENTS FOR INSPECTION OF VENTILATION EQUIPMENT 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN MECH. VENT SYSTEM 18-28-102 APPLICABILITY MAINTAIN MECHANICAL EQUIPMENT IN GOOD REPAIR TO PROVIDE ADEQUATE VENTILATION DURING HOURS OF OCCUPANCY 2600 W 35TH ST COMPLAINT FAILED View
NO PERMIT WIRING FOR BUILDOUT OF BANQUET HALL 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY SERVICE OR MAINTAIN FREIGHT CARS, NOT IN USE 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PERFORM CAT5 TEST - LAST TEST IS 2006 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY SERVICE #8 FREIGHT ELEVATOR 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA DETERMINE THE CONDITION OF SAFETY GOVERNOR AND BUFFERS BEFORE TEST 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE PROPER PULL STRAPS ON GATE AND HOISTWAY DOOR (A17.3-2.6.6) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE SAFETY EDGE OR SAFE HOISTWAY DOOR CLOSING (A17.3-2.6.5) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR THE LIGHTING INSIDE THE FREIGHT ELEVATOR 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE THE LOADING CLASS PLATE INSIDE THE FREIGHT AND NO PASSENGER SIGNAGE (A17.3-3.7.5) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA RED TAG VIOLATION-DISCONTINURE THE USE OF RUNNING FREIGHT WITH NO HOISTWAY DOORS ON 2ND LANDING 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA OBTAIN A CURRENT PASSENGER ELEVATOR CERTIFICATE FOR THE LOBBY HYDRAULIC 3-STOP ELEVATOR 2600 W 35TH ST PERIODIC FAILED View
THAT ON OR ABOUT 1-29-18 INSPECTION COMPLETED AND VIOLATION NOTICE PREAPRED AND FORWARDED FOR CIRCUIT COURT. 2600 W 35TH ST PERIODIC FAILED View
PROVIDE AUTOMATIC MIXING DEVIC MEN'S AND WOMEN'S RESTROOMS, ALL LAVATORIES NEED THERMOSTATIC MIXING VALVES (TMV) TO PREVENT SCALDING. 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE HOT/COLD WATER TO SINK BAR AREA - NOT HOT WATER TO HANDSINK AND BARSINK. 2600 W 35TH ST COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS BAR SINK LEAKING, NEED TO INSTALL AND TIGHTEN SLIPNUTS ON TAILPIECE UNDERSINK. 2600 W 35TH ST COMPLAINT FAILED View
KEEP FIXTUR CLEAN AND SANITARY KITCHEN AREA, BAR AREA AND RESTROOMS ARE FILTHY AND FOUL. 2600 W 35TH ST COMPLAINT FAILED View
INSTALL ILLUMINATION ALL HALLWAYS AND STAIWAYS (DANGEROUS CONDITION) 2600 W 35TH ST COMPLAINT FAILED View
SYSTEM II THROUGH OUT (DANGEROUS CONDITION) 2600 W 35TH ST COMPLAINT FAILED View
ADD RECEPTACLES TO EASE EXTENSION CORD USE IN BANQUET HALLS AND HALLWAYS AND STAIRWAYS (DANGEROUS CONDITION) 2600 W 35TH ST COMPLAINT FAILED View
LISTED FOR USE TEMP & LOCATION PROVIDE LABELS AND LISTING FOR LIGHTS BEING USED IN CEILING OF BANQUET HALL 2600 W 35TH ST COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE UNAPPROVED CORDS IN BANQUET HALL ( DANGEROUS CONDITION) 2600 W 35TH ST COMPLAINT FAILED View
INSTALL COVERS INSTALL COVERS FOR ALL OUTLETS AND SWITCHES IN BANQUET HALL (DANGEROUS CONDITION) 2600 W 35TH ST COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRING IN BANQUET HALLS (DANGEROUS AND HAZARDOUS) 2600 W 35TH ST COMPLAINT FAILED View
FIRE EXTNGSHR REQ, NONRESDNTL FIRE EXTINGUISHERS MISSING THROUGHOUT BUILDINGSECTION 15-16-640. 2600 W 35TH ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR ERECTED NEW PARTITIONS AT FIRST, SECOND AND 3RD FLOOR FOR NEW BUSINESS UNITS, STORAGE UNITS, ASSEMBLY UNITS AND MERCANTILE UNITS IN EXISTING 3 STORY INDUSTRIAL BUILDING. 2600 W 35TH ST COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT FAILED TO USE MATERIALS HAVING A FIRE RESISTANCE OF AT LEAST 4 HOURS TO SEPARATE ASSEMBLY OCCUPANCIES - 3RD FLOOR CONCRETE DECK BREACHED FOR NEW MECHANICALS AT SECOND FLOOR.SECTION 13-56-280. 2600 W 35TH ST COMPLAINT FAILED View
POST APPROVED OCCUPANCY CARD NO OCCUPANCY CARDS POSTED AT BANQUET HALLS AT SECOND AND 3RD FLOORSECTION 13-84-410. 2600 W 35TH ST COMPLAINT FAILED View
CLASS B DOOR IN STAIRWELL B-LABEL DOORS MISSING AT 3RD FLOOR STAIRWELL FIRE EXIT#8 AT NORTHWEST CORNER AND AT BRIDGEWAY CONNECTING CONNECTING 3RD FLOORS AT NORTH ELEVATION. 2600 W 35TH ST COMPLAINT FAILED View
NO EXIT FROM BUILDING AT GRADE FIRE EXIT #8 AT NORTHWEST CORNER CHAINED SHUT AT GRADESECTION 13-160-070. 2600 W 35TH ST COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT FAILED TO DISPLAY FLOOR PLAN AND EXIT DIAGRAM AT ASSEMBLY UNITS AT SECOND AND 3RD FLOOR.SECTION 13-84-400. 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 6012) 18-28-507 COMMERCIAL KITCHEN HOOD COMMERCIAL KITCHEN EXHAUST HOODS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 18-28-507 AND SHALL BETYPE I OR TYPE II & SHALL BE DESIGNED TO CAPTURE & CONFINE COOKING VAPORS -3RD FLOOR KITCHEN EXHAUST HOOD IS PHYSICALLY TO SMALL TO PROPERLY CAPTURE EXHAUST PLUME FROM COOKING EQUIPMENT NEEDS TO B E PROPERLY SIZED 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION 18-28-509 FIRE SUPPRESSION SYSTEM'S (1) COMMERCIAL FOOD HEAT PROCESSING APPLIANCES REQUIRED BY SECTION 18-28-507.2.1 TO HAVE A TYPE I HOOD SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM COMPLYING WITH BUILDING CODE 3RD FLOOR KITCHEN EXHAUST HAS NO FIRE SUPPRESSION SYSTEM 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION 18-28-711 CARBON MONOXIDE DETECTOR-NEED TO INSTALL CARBON MONOXIDE DETECTORS 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR THE LOCK ON LOBBY MACHINE ROOM DOOR TO BE SELF LOCKING WITH PROPER SIGNAGE 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A CODE DATA PLATE ON THE CONTROLLER FOR #1 & #8 ELEVATORS 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A FIRE SERVICE BOX WITH THE MACHINE ROOM KEY FOR THE LOBBY ELEVATOR 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A GROUNDING WIRE IN DISCONNECT FOR FREIGHT #8 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A ADDITIONAL LIGHTING IN MACHINE ROOM #8 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY REMOVE #11 FREIGHT ELEVATOR WITH PERMIT 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A GFCI IN MACHINE ROOM #8 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA SECURE MACHINE ROOM DOOR-PROVIDE LOCK 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE THE PROPER PERMIT TO DECOMMISSION #9 & #10 CURRENT PERMIT IS INCORRECT 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CALL FOR REINSPECTION TO PROPERLY IDENTIFY ALL PLATFORM LIFTS 2600 W 35TH ST PERIODIC FAILED View
MAINT PLATFORM LIFT OBTAIN CURRENT CERTIFICATE FOR ALL PLATFORM LIFTS 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CLASS LOADING AND NO PASSENGER SIGNAGE #8 2600 W 35TH ST PERIODIC FAILED View
WORKING SPACE PROVIDE 3 FEET OF WORKING SPACE AT PANEL 2600 W 35TH ST COMPLAINT FAILED View
EXPOSED WIRING EXPOSED WIRING AT WATER HEATER AND AT FIRE PUMP EQUIPMENT THROUGHOUT 2600 W 35TH ST COMPLAINT FAILED View
INSTALL COVERS PROVIDE COVERS FOR JUNCTION BOX'S THROUGHOUT 2600 W 35TH ST COMPLAINT FAILED View
RESTORE EXIT AND EM REPAIR EMERGENCY LIGHTING SYSTEM EXIT SIGNS BROKEN AND EMERGENCY BATTERY LIGHT HEADS ARE BROKEN 2600 W 35TH ST COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PERMIT FOR INSTALLATION OF AIR HANDLING UNIT 2600 W 35TH ST COMPLAINT FAILED View
PANEL SCHEDULES LABEL ALL PANELS AND BRANCH CIRCUITS 2600 W 35TH ST COMPLAINT FAILED View
CONTINUITY OF RACEWAYS REPAIR BROKEN CONDUITS THROUGH OUT WINDOW SHOP 2600 W 35TH ST COMPLAINT FAILED View
RESTORE EXIT AND EM 2600 W 35TH ST COMPLAINT FAILED View
CORD WIRED EQUIPMENT REMOVE CORD WIRING TO PERMANATELY INSTALLED EQUIPENT 2600 W 35TH ST COMPLAINT FAILED View
INSTALL COVERS CLOSE ALL OPEN BOX'S 2600 W 35TH ST COMPLAINT FAILED View
SECURE RACEWAY SUPPORT CONDUITS THROUGHOUT 2600 W 35TH ST COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRES IN REAR OF WINDOW SHOP 2600 W 35TH ST COMPLAINT FAILED View
RESTORE EXIT AND EM 2600 W 35TH ST COMPLAINT FAILED View
PANEL SCHEDULES LABEL ALL PANELS 2600 W 35TH ST COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE EXCESSIVE USE OF EXTENSION CORDS 2600 W 35TH ST COMPLAINT FAILED View
SECURE RACEWAY SUPPORT LOOSE CONDUITS 2600 W 35TH ST COMPLAINT FAILED View
CONTINUITY OF RACEWAYS MISSING ELECTRICAL CONDUIT FITTING AT HEATER 2600 W 35TH ST COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PERMITS FOR ALL BUILDOUTS 2600 W 35TH ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS ALL SERVICES MUST BE GROUPED 14E 2-230.72 2600 W 35TH ST COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXCESSIVE USE OF EXTENSION CORDS 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTIOM REQUIRED ARRANGE FOR COMPLETE PERMIT IMSPECTION & OBTAIN PERMITED WHEN WORK IS COMPLETE 2600 W 35TH ST COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT 13-32-13 OPERATIONS WITHOUT PERMIT SUBMIT PLANS & OBTAIN VENTILATION SYSTEM PERMIT NEED TO SUBMIT FOR TENANT BUILD OUT PERMIT FOR DULCE LANDI WAREHOUSE 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE SUPPLY 18-28-403.3 VENTILATION REQUIREMENTS PROVIDE MECHANICAL SUPPLY VENTILATION AT CUBIC FEET PER-MINUTE EQUAL TO SOURCE FEET OF FLOOR AREA TIMES FACTOR BASED ON USE NEED TO PROVIDE SUPPLY VENTILATION FOR ACTIVE WAREHOUSE 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED4D ARRANGE FOR COMPLETE PERMIT INSPECTION & OBTAIN PERMITS FOR VENTILATION SYSTEMS WHEN WORK IS COMPLETED 2600 W 35TH ST COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT 1 3-32-010 PERMIT REQUIRED 13-32-130 OPERATIONS WITHOUT PERMIT SUBMIT PLANS & OBTAIN VENTILATION -PERMIT FOR TENANT BUILD OUT (COLD STORAGE UNIT) 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION 18-28-403.3 #2 OCCUPIED REFRIGERATION ROOMS REQUIRE 0.6 CFM PER SQUARE VENTILATION & EXHAUST NEED TO PROVIDE SUPPLY VENTILATION & EXHAUST AS PER CODE FOR OCCUPIED COLD STORAGE UNIT 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 3019) 18-28-502.3 BATTERY CHARGING AREAS VENTILATION SHALL BE PROVIDED IN AN APPROVED MANNER IN BATTERY CHARGING AREAS TO PREVENT A DANGEROUS ACCUMULATION OF FLAMMABLE GASES NEED A DEDICATED EXHAUST FAN FOR BATTERY CHARGING AREA FOR FORK LIFTS 2600 W 35TH ST COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT 13-32-130 OPERATIONS WITHOUT PERMIT SUBMIT PLANS & OBTAIN VENTILATION SYSTEM PERMIT NEED TO SUBMIT FOR TENANT BUILDOUT PERMIT FOR SMALL ASSEMBLY THEATER 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE SUPPLY 18-28-403.3 VENTILATION REQUIREMENTS PROVIDE MECHANICAL SUPPLY VENTILATION AT CUBIC FEET PER MINUTE EQUAL TO SQUARE FEET OF FLOOR AREA TIMES FACTOR BASED ON USE NEED TO PROVIDE SUPPLY VENTILATION FOR SMALL ASSEMBLY THEATER 2600 W 35TH ST COMPLAINT FAILED View
GIVE VENT OPENINGS % FL. AREA 18-28-403.3 PROVIDE MECHANICAL EXHAUST T CUBIC FEET PER MINUTE EQUAL TO SQUARE FEET OF FLOOR AREA TIMES FACTOR BASED ON USE NEED TO PROVIDE EXHAUST VENTILATION FOR THEATER 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE FOR COMPETE PERMIT VENTILATION & OBTAIN PERMIT FOR WARM AIR HEATING SYSTEM & VENTILATION SYSTEMS WHEN WORK IS COMPLETE (18-28-106.1) 2600 W 35TH ST COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT OPERATIONS WITHOUT PERMIT NEED TO SUBMIT & OBTAIN TENANT BUILDOUT PLANS & PERMIT FOR WINDOW MANUFACTURING CO. 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE SUPPLY 18-28-403.3 VENTILATION REQUIREMENTS PROVIDE MECHANICAL SUPPLY VENTILATION AT CUBIC FEET PER MINUTE EQUAL TO SQUARE FEET OF FLOOR AREA TIMES FACTOR BASED ON USE NEED TO PROVIDE OUTSIDE AIR FOR WINDOW MANUFACTURING CO. THERE'S NO OUTSIDE VENTILATION AIR FOR ENTIRE PLANT 2600 W 35TH ST COMPLAINT FAILED View
GIVE VENT OPENINGS % FL. AREA 18-28-403.3 VENTILATION REQUIREMENTS PROVIDE MECHANICAL EXHAUST VENTILATION AT CUBIC FEET PER MINUTE TIMES FACTOR BASED ON USE NEED TO PROVIDE GENERAL EXHAUST FOR ENTIRE MANUFACTURING & OFFICE AREA & NEED TO PROVIDE EXHAUST FOR DOCK AREA 2600 W 35TH ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT3019) 18-28-502.3 BATTERY CHARGING AREA VENTILATION SHALL BE PROVIDED IN AN APPROVED MANNER IN BATTERY CHARGING AREAS TO PREVENT A DANGEROUS ACCUMULATION OF FLAMMABLE GASES NEED TO PROVIDE EXHAUST FOR BATTERY CHARGING AREA 2600 W 35TH ST COMPLAINT FAILED View
DUST SEPARATOR OUTSIDE OF BLDG 18-28-511.1.1 COLLECTORS AND SEPARATORS CYCLONE COLLECTORS & SEPARATORS AND ASSOCIATED SUPPORTS SHALL BE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL & SHALL BE LOCATED ON THE EXTERIOR OF THE BUILDING OR STRUCTURE NEED TO INSTALL A REMOTE DUST COLLECTION SYSTEM FOR ALL MACHINERY EXCESSIVE AMOUNT OF DUST THROUGH OUT ENTIRE MANUFACTURING PLANT 2600 W 35TH ST COMPLAINT FAILED View
STOP RECIRC.AIR F/CONTAMT'D. R 18-28-502 EXHAUST SYSTEMS NEED TO REMOVE DANGEROUS & HAZARDOUS NON CODE CONFORMING SPRAY BOOTH & INSTALL A UL LISTED & APPROVED SPRAY BOOTH COMPLETE WITH PROPER DEDICATED EXHAUST & SUPPLY AIR AS PER CODE 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-1096.1 ARRANGE FOR COMPLETE PERMIT INSPECTION & OBTAIN PERMIT FOR VENTILATION SYSTEMS WHEN WORK IS COMPLETE 2600 W 35TH ST COMPLAINT FAILED View
NO ENTRY 2600 W 35TH ST PERIODIC FAILED View
OPEN TYPE VIOLATION 13-196-750 HEAT REQUIRED NEED TO PROVIDE HEAT TO WAREHOUSE 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR EMERGENCY LIGHT IN LOBBY ELEVATOR 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CLOSE OUT PERMIT NO. 100782592 (CAR #2) (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A CURRENT MAINTENANCE CONTROL PROGRAM FOR ALL ELEVATORS (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CLOSE OUT PERMIT NO. 100812324 - CAR #9 (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR/REPLACE EMERGENCY PHONE. PROGRAM PHONES TO A 24 HR MANNED ANSWERING SERVICE. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CLOSE OUT PERMIT NO. 100812325 - CAR #10 (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY REMOVE #11 FREIGHT ELEVATOR WITH PERMIT. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR NO. 8 FREIGHT ELEVATOR THAT'S BEEN RED TAGGED. CALL FOR REINSPECTION BEFORE RETURNING TO SERVICE. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA BUILDING TO COORDINATE AN INSPECTION WITH THE CITY OF CHICAGO'S ELEVATOR BUREAU, TO IDENTIFY ALL ELEVATORS AND HOISTWAYS, BOTH RUNNING AND OUT OF SERVICE. TO DETERMINE IF THE IN COMPLIANCE OR REMOVED PROPERLY. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINT PLATFORM LIFT BUILDING TO COORDINATE AN INSPECTION WITH THE CITY OF CHICAGO'S ELEVATOR BUREAU, TO IDENTIFY ALL PLATFORM LIFTS, BOTH RUNNING AND OUT OF SERVICE. TO DETERMINE IF THEY ARE IN COMPLIANCE OR REMOVED PROPERLY. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA OBTAIN A CURRENT PASSENGER ELEVATOR CERTIFICATE FOR THE LOBBY HYDRAULIC 3-STOP ELEVATOR. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR THE LOCK ON LOBBY MACHINE ROOM DOOR TO BE SELF LOCKING WITH PROPER SIGNAGE. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A FIRE SERVICE BOX WITH THE MACHINE ROOM KEY FOR THE LOBBY ELEVATOR. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY SERVICE OR MAINTAIN FREIGHT CARS, NOT IN USE. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE NON SHEARING ASTRAGALS ON ALL BI PARTING FREIGHT HOISTWAY DOORS (ALL OPENINGS, ALL CARS) PER A17.3 SECTION 3.2.6.5. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE HOISTWAY DOOR VISION PANALS ON ALL FREIGHT HOISTWAY DOORS PER A17.3 SECTION 2.6.3. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE PULL STRAPS ON ALL MANNUALY OPERATED FREIGHT DOORS AND GATES PER A17.3 SECTION 2.6.6. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE PROPER FIRE RATED HOISTWAY DOOR WITH INTERLOCK ON FREIGHT ELEVATOR #8. UNIT RED TAGGED. DO NOT USE. PENDING DECOMMISSION PERMIT # 100948844. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE EMERGENCY PIT STOP SWITCH. FREIGHT ELEVATORS. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE LIGHTING IN ALL FREIGHT ELEVATOR PITS. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CODE COMPLIANT PIT ACCESS LADDERS FOR SAFETY. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE EMERGENCY 2 WAY COMMUNICATIONS (FREIGHT ELEVATORS). 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE A MAINTENANCE CONTROL PROGRAM FOR ALL ELEVATORS. (REF. A17.1 - 8.6.1.2) 2600 W 35TH ST PERIODIC FAILED View
SEE INSPECTOR COMMENTS FLEXIBLE METAL CONDUIT NEEDS TO BE REPLACED AT AIR HANDLING UNIT 14E-3-348.10 2600 W 35TH ST COMPLAINT FAILED View
SECURE RACEWAY 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE FOR INSPECTION 18-28-106.1 SR # 14-00124262 2600 W 35TH ST COMPLAINT PASSED View
REPAIR LINTELS RUSTED LINTELS AT NORTH ELEVATION. 2600 W 35TH ST PERIODIC FAILED View
ARRANGE ANNUAL INSP. ARRANGE FOR ANNUAL MECHANICAL VENTILATING SYSTEM INSPECTION 13-20-290 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE WORK WITHOUT A PERMIT CODE 18-28-106.1 18-28-106.1 2600 W 35TH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR THE LIGHTING INSIDE THE FREIGHT ELEVATOR 2600 W 35TH ST PERIODIC CLOSED View
STOP NUISANCE TO EMPLOYEES STOP NUISANCE TO EMOLOYEES 7-28-080 2600 W 35TH ST COMPLAINT FAILED View
REPAIR OR REPLACE REPAIR AN REPLACE FLUE EXHAUST IN SUITE 300 DU LEELANDIA DANGEROUS AND HAZARDOUS UNIT HEATER FLUE RUNNING INTO TOILET EXH 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE CHANGE OF OCCUPANCY 2600 W 35TH ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 3RD FLOOR NORTH EXIT #2 SLIDE BOLT 2ND FLR TOWER 6-SLIDE BOLTS 2 FLOOR/TOWER 3 SLIDE BOLTS ALL ELEVATIONS MULTIPLE LOCATIONS SPALLING CONCRETE AND BRICKS, PERMIT REQUIRED FOR MASONRY REPAIRS 2600 W 35TH ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 3RD FLOOR MULTIPLE LOCATIONS NO HEAT PROVIDED 2600 W 35TH ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM 3RD FLR CHICAGO CAFFE/WEST STAIRS-MISSING SECONDARY HANDRAIL, MISSING RETURNS AT HANDRAIL. 2600 W 35TH ST COMPLAINT FAILED View
MAINT PLATFORM LIFT PROVIDE A CERTIFICATE FRAME FOR ALL PLATFORM LIFTS. (PREVIOUSLY CITED) 2600 W 35TH ST PERIODIC FAILED View
MAINT PLATFORM LIFT REPAIR OR SECURE PERMITS TO DECOMMISSION ALL NON OPERATIONAL DOCK LIFTS (UNITS 2-10 AND UNITS 11-15 AND UNITS 17, AND 18. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE AN EMERGENCY PHONE IN ELEVATOR 2600 W 35TH ST PERIODIC FAILED View
MAINT PLATFORM LIFT VERIFY REPAIR, OR DECOMMISSION DOCK LIFTS 11-15. UNABLE TO ACCESS. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE ACCESS TO ALL ELEVATORS 2600 W 35TH ST PERIODIC FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED ARRANGE COMPLETE PERMIT INSPECTION & OBTAIN PERMIT FOR VENTILATION WORK WHEN WORK IS COMPLETE 2600 W 35TH ST COMPLAINT FAILED View
PROVIDE SUPPLY 18-28-403.3 VENTILATION REQUIREMENT PROVIDE MECHANICAL SUPPLY VENTILATION AT CUBIC FEET PER MINUTE EQUAL TO SQUARE FEET OF FLOOR ARE TIMES FACTOR BASED ON USE NEED TO FINISH INSTALLING OUTSIDE AIR INTAKE FOR AIR HANDLER FOR INDOOR SOCCER FIELD 2600 W 35TH ST COMPLAINT FAILED View
ARRANGE ANNUAL INSP. 2600 W 35TH ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PERFORM CATEGORY ONE TEST AND CATEGORY FIVE TEST, AS NEEDED FOR ELEVATOR'S(3). PROVIDE DOCUMENTATION AND TEST TAGS. 2600 W 35TH ST PERIODIC FAILED View
MAINT PLATFORM LIFT BUILDING TO COORDINATE AN INSPECTION WITH THE CITY OF CHICAGO'S ELEVATOR BUREAU, TO IDENTIFY ALL PLATFORM LIFTS, BOTH RUNNING AND OUT OF SERVICE. TO DETERMINE IF THEY ARE IN COMPLIANCE OR REMOVED PROPERLY. (PREVIOUSLY CITED - 3 TIMES) 2600 W 35TH ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ACCESS TO INTERIOR FOR 2019 ANNUAL INSPECTION. 2600 W 35TH ST PERIODIC CLOSED View