Last Modification Date: 2024-10-23 @ 9:09 PM
PIN: 20172100090000
Property Address: 5621 S ABERDEEN ST
City - Zip: CHICAGO - 60621
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72091
2023 Tax District: 72082
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 33 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED DETECTOR AND OCCUPANCY. 5621 S ABERDEEN ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED. 5621 S ABERDEEN ST COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS WEST AND EAST ELEVATION - HIGH WEEDS. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION - EXTERIOR WALL , WASHED OUT MORTAR AND SHIFTING BRICKS. 5621 S ABERDEEN ST COMPLAINT CLOSED View
PARAPET SOUTH ELEVATION - PARAPET WALL . WASHED OUT MORTAR AND SHIFTING BRICKS. 5621 S ABERDEEN ST COMPLAINT CLOSED View
DEBRIS, EXCESSIVE WEST ELEVATION - TRASH AND BOTTLES IN FRONT YARD. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPAIR DOOR FRAME, MULLION 2ND FLOOR - REAR EXTERIOR DOOR , MISSING BRICK MOLD , LOCKS EXPOSED. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPLACE D&H PORCH EAST ELEVATION - REAR PORCH / 6X6 COLUMNS FOUNDATION STATUS UNKNOWN. SOME COLUMN HALF -LAP JOINTS NOTCH ONLY 8" DEEP WITH MISSING BOLTS AND LOCK WASHERS , AND SOME TOE- NAILED ONLY AT SPLICE CONNECTION. TREADS CRACKED. 1ST AND 2ND FLOOR RAILING SECTIONS 10"-18" GAP BETWEEN BOTTOM RAIL AND TOP OF TREAD. 2ND FLOOR GUARDRAIL LOOSE. 2ND FLOOR STRINGER, GAP AT WALL, MISSING BOLT AT EXTERIOR WALL. 2X8 RIM JOIST ONLY TOE-NAILED TO COLUMNS.2X8 JOIST UNDERSIZED AND SPAN FROM 12'-15 ' FEET . BEAM TO COLUMN CONNECTION MISSING HARDWARE ,PULLING APART AT FIRECUT AND WASHED OUT MORTAR WITH NO VISIBLE STRAPS.SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH. 5621 S ABERDEEN ST COMPLAINT CLOSED View
MICE/RODENTS 1ST AND 2ND FLOOR APARTMENT - MICE, OPENINGS IN CEILING AND FLOORS IN HEATING CLOSETS. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPAIR FLOOR 2ND FLOOR APARTMENT - EXTERIOR DOOR MISSING FLOOR TRIM NEAR BACK DOOR, BLACK ANTS. 5621 S ABERDEEN ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED. 5621 S ABERDEEN ST COMPLAINT CLOSED View
CUT OR REMOVE HIGH WEEDS WEST AND EAST ELEVATION - HIGH WEEDS. 5621 S ABERDEEN ST COMPLAINT CLOSED View
DEBRIS, EXCESSIVE WEST ELEVATION - TRASH AND BOTTLES IN FRONT YARD. 5621 S ABERDEEN ST COMPLAINT CLOSED View
MICE/RODENTS 1ST AND 2ND FLOOR APARTMENT - MICE, OPENINGS IN CEILING AND FLOORS IN HEATING CLOSETS. 5621 S ABERDEEN ST COMPLAINT CLOSED View
REPAIR FLOOR 2ND FLOOR APARTMENT - EXTERIOR DOOR MISSING FLOOR TRIM NEAR BACK DOOR, BLACK ANTS. 5621 S ABERDEEN ST COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BLDG. - MISSING OWNER'S I.D. SIGN. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL - WASHED OUT MORTAR, WITH SHIFTING BRICKS. 5621 S ABERDEEN ST COMPLAINT FAILED View
PARAPET PARAPET WALL - WASHED OUT MORTAR, WITH SHIFTING BRICKS. 5621 S ABERDEEN ST COMPLAINT FAILED View
CHIMNEY CHIMNEY - WASHED OUT MORTAR, WITH LOOSE AND MISSING BRICKS. 5621 S ABERDEEN ST COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT STAIRWAY - MISSING GUARDRAIL AT GRADE. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION REAR FOUNDATION - RETAINING WALLS WASHED OUT MORTAR, WITH LOOSE BLOCKS, RUBBLE STONES AND CAPPING. 5621 S ABERDEEN ST COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR 6 FEET REAR WOODEN FENCE ERECTED WITHOUT A PERMIT. 5621 S ABERDEEN ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS INTERIOR STAIRWAY - MISSING SMOKE DETECTOR AT TOP. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPLACE D&H PORCH 2-STORY REAR PORCH: 4X4 AND 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X8 DECK JOISTS SPAN 15 FEET, WITH LANDING JOISTS ONLY TOE-NAILED TO RIM JOIST. COLUMNS WITH INADEQUATE HALF-LAP JOINTS, HAVING OVERLAP OF ONLY 8 INCHES AND MISSING BOLTS - ONLY TOE-NAILED AT SPLICE CONNECTIONS. 1 TO 2 RAILING SECTIONS 10 -18 INCHES GAP BETWEEN BOTTOM RAILS AND TOP OF TREADS. GRADE TO 1 TREADS AND RISERS LOOSE AND CRACKED, WITH ABOUT 4 INCHES GAP BETWEEN WALL AND STRINGERS. BEAM TO COLUMN CONNECTIONS ONLY TOE-NAILED, MISSING HARDWARE AND PULLING AWAY FROM FIRECUT, WITH BEAM POCKETS WASHED OUT MORTAR. ENTIRE STRUCTURE IS WEAK, DANGEROUS AND UNSTABLE. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. 5621 S ABERDEEN ST COMPLAINT FAILED View
REPAIR DOOR FRAME, MULLION 2ND FLOOR - REAR EXTERIOR DOOR , MISSING BRICK MOLD , LOCKS EXPOSED. 5621 S ABERDEEN ST COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND PERMITS AUTHORING WORK PERFORMED IN BASEMENT PREVIOUS STORAGE NOW A DWELLING UNIT KITCHEN, BATH AND BEDROOMS IN BASEMENT 5621 S ABERDEEN ST COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL FIXTURES INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN BASEMENT CAP ALL PLUMBING SUPPLY LINES 5621 S ABERDEEN ST COMPLAINT FAILED View
LIGHT AND VENT BASEMENT-GLASS BLACK WINDOWS ALL ELEVATIONS IN BASEMENT APARTMENT 5621 S ABERDEEN ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST FLOOR FORCED AIR FURNACE KEEPS TURNING ON AND SHUTTING OFF. 5621 S ABERDEEN ST COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE 1ST FLOOR FRONT DOOR DRAFTY. 5621 S ABERDEEN ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED DETECTOR AND OCCUPANCY. 5621 S ABERDEEN ST COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR EAST ELEVATION - GRADE TO BASEMENT / HANDRAIL AND GUARDRAIL , MISSING. 5621 S ABERDEEN ST COMPLAINT CLOSED View
UNAPPROVED HEATING DEVICE 5621 1ST FLOOR USING STOVE TO HEAT APARTMENT. 5621 S ABERDEEN ST COMPLAINT FAILED View