The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF EXISTING MASONRY 2 STORY BUILDING INCLUDING BUT NOT LIMITED TO FULL REHAB ALL LEVELS INCLUDING FRAMING PLUMBING ELECTRICAL AND VENTILATION REQUIRES FULL SET OF PLANS | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | ERECTING NEW 20FT X 21FT REAR FRAME GARAGE WITH 10FT HIGH OVERHEAD DOOR | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PERMIT IS OBTAINED 14A-3-306-1 14A-4-411-1 14A-4-401-1 | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR IN BASEMENT APARTMENT. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTOR IN BASEMENT APARTMENT. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | WINDOW FRAMES GAPS DRAFTY WINDOWS AIR SEEPAGE. MOLD ON BATHROOM WALLS. 3 UNITS | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | WINDOWS - ALL ELEVATIONS FIRST FLOOR WINDOWS DEFECTIVE WINDOW FRAMES MUST KEEP RAIN AND WIND OUT OF DWELLING. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION FRONT ONE STORY WOOD STAIRS - COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES, FOUNDATION STATUS UNKNOWN. LEDGER BEAM FASTENED TO BUILDING EXTERIOR WALL WITH SOME BOLTS. BEAM NOT TIED BACK TO THE WALLS INSIDE BEAM POCKETS; MISSING STRAPS. JOISTS FASTENED TO BEAMS, HEADER BEAMS, RIM JOIST TOE NAILED ONLY. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS TOE NAILED ONLY. TREADS AND RISERS WORN. DECK BOARDS WORN. METAL GUARD RAILS AND HAND RAILS RUSTED AT CONNECTION POINTS. PERMITS ONLY REQUIRED TO REPAIR/REPLACE EXTERIOR STAIRS. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION REAR ENCLOSED TWO STORY WOOD PORCH - COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES, FOUNDATION STATUS UNKNOWN. BEAMS TOE NAILED TO COLUMNS AND NORTH BEAM AT SECOND FLOOR LANDING AREA CRACKED AT COLUMN CONNECTION POINT AND BEAMS NOT TIED BACK TO THE WALLS INSIDE BEAM POCKETS; MISSING STRAPS. JOISTS FASTENED TO HEADER JOISTS WITH TOE NAILS, MISSING BLOCKING. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST AND COLUMNS WITH NAILS. LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT DECKS, COLUMNS AND HEADER JOISTS WITH NAILS ONLY. TREADS AND RISERS WORN. DECKING BOARDS WORN. STAIR RAILING SECTIONS FASTENED TO COLUMNS WITH NAILS ONLY AND RAILING SECTION MEMBERS BROKEN AND MISSING PICKETS DANGEROUS AND HAZARDOUS. INTERIOR WALLS OF REAR ENCLOSED PORCH OPEN SOME AREAS PLYWOOD INSTALLED ALONG SURROUNDING WALLS. PLANS AND PERMITS REQUIRED TO REPAIR REAR PORCH. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | STORAGE UNDER REAR PORCH - ACCUMULATION OF HOUSEHOLD ITEMS AND WATER HEATER. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | FIRST FLOOR UNIT AND REAR ENCLOSED PORCH MISSING CARBON MONOXIDE DETECTOR | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH AND FIRST FLOOR UNIT MISSING SMOKE DETECTOR. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED FOR INSTALLATION OF WATER HEATER UNDER BACK REAR PORCH. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | FRONT WEST ELEVATION SECOND FLOOR WOOD BALCONY, UNDERSIDE OF BALCONY COVERED WITH UNKNOWN BOARD MUST REMOVE BOARD TO INSPECT UNDERSIDE AREA -BEAMS NOT TIED BACK TO WALLS INSIDE BEAM POCKETS; MISSING STRAPS. GUARD RAILING METAL SECTIONS RUSTING AT ALL CONNECTION POINTS AND SCREWED ONLY. PLANS AND PERMITS REQUIRED TO REPAIR BALCONY | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER/MANAGEMENT ID SIGN POSTED. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FIRST FLOOR REAR DOOR DAMAGED FRAME AND DOOR | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FIRST FLOOR UNIT BATHROOM WALLS WATER DAMAGED AND TILES HAVE BLACK SUBSTANCE. | 1039 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |