The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | 07-01407449- 07-01407470 OWNER'S ID SIGN NOT POSTED | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT - 4X4 COLUMNS ARE RESTED ON SOIL AND ARE LOOSE. LOOSE BUCKLED UP TREADS. LOOSE HARD RAILS IMPROPER CONNECTIONS- MOST MEMBERS ARE TOE NAILED TOGETHER. STAIRS SWAY NOTICEABLY UPON LOAD. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS OR REPLACEMENT. | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR DECK AT 2 GUARDRAILS ARE ONLY 36 INCHES IN HEIGHT, SEVERAL SECTIONS ARE WORN AND SPLITTING AT THE POST CONNECTIONS. CATWALK FROM THE MAIN STRUCTURE TO THE CARSLE WITH ONLY TWO 4X4 COLUMNS RETED ON CONCRETE. CENTER JOIST IS FRACTURED IMPORPER CONNECTIONS MOST MEMBERS ARE TOE NAILED TOGETHER AN ARE SEPARTE AT THE CONNECTIONS. PLANS AND PERMITS ARE REQUIRED FOR REPAIRS OR REPLACEMENT | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT OVERHANG COLUMNS ARE RESTED ON A CONCRETE BASE FOUNDATION STATUS IS UNKNOWN. SOUTH COLUMN IS ROTTED AND CENTERED ON THE BASE. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS OR REPLACEMENT | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT/NORTH SIDE OF GARAGE HIGH WEEDS SEC(SEC7.28.1203) | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR YARD UNDER CATWALK DOG, FECES | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
REMOVE | REAR YARD LADDER IS CHAINED TO THE CATWALK IN THE VERTICAL POSITION (SEC 7-28-060) | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | GARAGE/BUILDING INTERIOR- NO REPONSE UNVERIFED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO VERIFY COMPLAINT OF TUBE COMING THRU THE FLOORS LEAKING PIPES, MOLD THRU OUT | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE, AROUND AND UNDER PORCH. | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO ENTRY, UNABLE TO VERIFY COMPLAINT OF ILLEGAL UNITS AND WORK WITHOUT PERMIT. | 5102 S MULLIGAN AVE | COMPLAINT | FAILED | View |