Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALL MORTAR MISSING. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
PARAPET | NORTH PARAPET WALL BUCKLING AND MORTAR MISSING. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR COPING | NORTH COPING TILES MISSING. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR WOOD DOORS ROTTED, WOOD SPLIT, METAL DOORS RUSTED OUT. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EXTERIOR WOOD DOOR FRAMES ROTTED, WOOD SPLIT, METAL DOOR FRAMES RUSTED. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR EAVES | SOUTH ELEVATION FASCIA BOARD ROTTED, METAL SIDING MISSING AND LOOSE. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | SR#801997687 NO PERMIT POSTED FOR ROOF REPAIRS EAST ELEVATION TORN AND MISSING ROOFING MATERIAL. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | SR#801997687 NO PERMIT POSTED FOR ROOF REPAIRS EAST ELEVATION TORN AND MISSING ROOFING MATERIAL. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | FRONT MISSING ADDRESS DISPLAY | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
PARAPET | PARAPET WALL ON THE NORTH EAST ELEVATION ERODED MORTAR JOINTS AND SPRAWLING AND MISSING BRICK. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | LINTELS ON THE NORTH ELEVATION OVER DOOR WAY, NORTHEAST ELEVATION OVER WINDOWS AND DOOR OPENINGS. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE GARDEN HOSE FOR GRANITE CUTTING SAW THAT RUNS FROM SOUTH ELEVATION OF 6823 TO NORTH ELEVATION 6833. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE RPZ FOR GRANITE WATER CUTTING SAY NORTH ELEVATION OF 6833. 18-29-608.13.2. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE SERVICE SINK AND DRINKING FOUNTAIN FOR WAREHOUSE 6821 - 6851. 18-29-403.2 AND 403.4. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE TEMPERING VALVES AT MENS AND WOMENS LAVATORIES - 6819 FIRST FLOOR. 18-607.1. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMITS FOR SECOND FLOOR LARGE ASSEMBLY - 6817. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE TEMPERING VALVE AT LAVATORIES - 6817 SECOND FLOOR RESTROOMS. 18-29-607.1. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE FLOOR DRAIN FOR WATER HEATER - NORTHEAST ELEVATION OF 6817 SECOND FLOOR. 18-29-412.4. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | PROVIDE OPEN FRONT TOILET SEATS ON ALL TOILETS AT 6817 SECOND FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMITS FOR VIOLATIONS AT 6817-51. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK AT 6817-51. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SEAL DRAIN OPENING UNUSD FIXTR | OPEN TWO INCH BENT PIPES SOUTHEAST ELEVATION - 6823 FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE FIRST AND SECOND FLOOR AT 6817 SOUTH CHICAGO AND FIRST FLOOR OF 6819, 6821, AND 6823 S SOUTH CHICAGO 13-12-380 | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View | |
PRV DISCHARGE PIPE FROM PRV | DISCHARGE PIPE MISSING FOR RELIEF VALVE, 6819 FIRST FLOOR NORTH ELEVATION. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FLEXIBLE SUPPLIES ON LAVATORY IN WOMENS RESTROOM AND KITCHEN FAUCET IN 6817 SECOND FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SYSTEM III | INSTALL EMERGENCY LIGHTING SYSTEM III THROUGHOUT BUILDING, FIRST AND SECOND FLOORS. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES THROUGHOUT FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | 6817 - NO OWNER POSTING. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | 6817 - WEST WALL HAS STRESS CRACK. NORTH WALL DEFLECTS OUT AND MISSING MORTAR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
POST APPROVED OCCUPANCY CARD | 6817 - MISSING OCCUPANCY CARD. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 6817 - SHOW PROOF OF 4 HOUR FIRE SEPARATION FROM LARGE ASSEMBLY TO MERCANTILE BELOW. 13-56-280. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | SECOND FLOOR SOCIAL CLUB/LARGE ASSEMBLY 2139 SQ FT WITH AN EXIT CAPACITY OF 356 PEOPLE. THE FRONT AND REAR EXITS HAVE A COMBINED CAPACITY FOR 180 PEOPLE. THERE IS AN INSUFFICIENT AMOUNT OF EXITS FOR THIS 6817 - TYPE OF OCCUPANCY. PROVIDE ADDITIONAL EXITS TO HANDLE THE 356 CAPACITY. 13-84-180B.6817 | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 6817 - FRONT AND REAR EXIT STAIRWELLS REQUIRE ONE HOUR FIRE RATED DOOR ASSEMBLY AND HARDWARE. 13-160-500A. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 6817 - FRONT AND REAR EXIT DOORS REQUIRE PANIC HARDWARE. 13-160-260B. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 6817 - REAR EGRESS EXIT DOOR ONLY 32 INCHES WIDE, ALL EXIT DOORS REQUIRE 36 INCHES FROM SECOND TO FIRST. 10(13-160-220A). | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | 6817 - MISSING FIRE EXTINGUISHERS. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 6817 - SECOND FLOOR SOCIAL CLUB HAS WOOD FRAMED NON-LOAD BEARING WALLS FORMING A STORAGE ROOM AND ONE MENS RESTROOM AND ONE WOMENS RESTROOM. REQUIRES PLANS AND PERMITS. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 6819 - INTERIOR BUILD OUT WITH WOOD PARTITION WALLS CONTAINING THREE LARGE ROOMS WITH TWO RESTROOMS AND ONE SMALLER ROOM HAS A WOOD FRAMED BAR. ALL WORK WAS COMPLETED WITHOUT THE REQUIRED PLANS AND PERMITS. REPAIRS TO BOW TRUSS ROOF REQUIRES PERMIT. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | 6819 - MISSING FIRE EXTINGUISHER. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
RATS-ELEVATE MATERIAL 18" | 6821 - WOOD PALLETS, MISC. WOOD STORED AND SITTING ON GROUND. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
REMOVE | 6821 - USING A PROPANE HEATER FOR HEAT. IMPROPER APPLICATION OF PROPANE HEATER IS DANGEROUS IN THIS SITUATION. 13-196-440. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 6821 - MISSING CARBON MONOXIDE DETECTOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | 6821 - DISCONTINUE USING AS AN AUTO REPAIR SHOP. NOT SET UP FOR A REPAIR SHOP. NUMEROUS CAR ENGINES THROUGHOUT REAR OF BUILDING. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | 6823 - EXPIRED FIRE EXTINGUISHER TAG. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | 6823 - BOW STRING TRUST HAS HOLLOW METAL TUB SHORING SITTING ON UNKNOWN AND BLOCKS OF WOOD FOOTINGS. WILL REQUIRE A STRUCTURAL ENGINEERS REPORT. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | 6833 - STORED RIDING LAWN MOWERS, BACKHOES, CRANE, AUTOMOBILES, CONSTRUCTION MATERIALS. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMITS FOR RESTROOM - 6821 SOUTHWEST ELEVATION. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER - 6821 | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE PROPER GREASE INTERCEPTOR FOR AUTOMOBILE REPAIR SHOP - 6821 FIRST FLOOR NORTH ELEVATION, 18-29-1003.7.2. AND 6833 WHERE MACHINES ARE STORED (BACKHOE, DUMP TRUCK, BOB CATS, CARS). | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FLEXIBLE SUPPLIES ON LAVATORY AND TOILET - WEST ELEVATION AT 6819 FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | PROVIDE OPEN FRONT TOILET SEAT - WEST ELEVATION RESTROOM AT 6819 FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMITS FOR RESTROOMS AND KITCHEN - 6819 FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL PVC WASTE PIPE FOR RESTROOMS SOUTH ELEVATION AND KITCHEN AREA NORTH ELEVATION - 6819 FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE MINIMUM NUMBER OF PLUMBING FIXTURES FOR A LARGE ASSEMBLY. TOTAL AT TIME OF INSPECTION WAS TWO RESTROOMS TOTAL WITH ONE LAVATORY AND TOILET IN EACH RESTROOM. NO SERVICE SINK OR DRINKING FOUNTAIN AT 6819 FIRST FLOOR. 18-29-403.1. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE THE REQUIRED DIAGRAM AND LOAD CALCULATIONS FOR FEEDERS, SERVICES, AND REQUIRED EQUIPMENT 18-27-215.5 | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER THROUGHOUT 6817 S SOUTH CHICAGO ON THE FIRST AND SECOND FLOOR AREAS AND 6819, 6821, 6823 S SOUTH CHICAGO ON THE FIRST FLOOR AREAS 18-27-110.12 | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View | |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS AND PERMITS THROUGHOUT 6817 S SOUTH CHICAGO FIRST AND SECOND FLOOR AREAS AND 6819, 6821, 6823 FIRST FLOOR AREAS, INCLUDING THE NEW 800 AMP SERVICE 13-12-360 | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE MINIMUM NUMBER OF PLUMBING FIXTURES FOR A LARGE ASSEMBLY OF 356 PEOPLE. TOTAL AT TIME OF INSPECTION: MENS ROOM WITH ONE LAVATORY, ONE TOILET, AND ONE URINAL; WOMENS RESTROOM WITH ONE LAVATORY AND TWO TOILETS. NO SERVICE SINK OR DRINKING FOUNTAIN FOR 6817 SECOND FLOOR. 18-29-403.1. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 6817 - FRONT AND REAR EXIT STAIRWELLS REQUIRE A ONE HOUR FIRE RATED WALL. 15-8-140. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | NO FLOOR DRAIN AT WATER HEATER NORTH ELEVATION OF 6819 AT FIRST FLOOR. 18-29-412.4. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
WORK CONTRARY TO PERMIT | FOLLOW UP INSPECTION REVEALS THAT TRUSS REPAIR DEVIATES FROM APPROVED PLAN. BUILDING OWNER IS ORDERED IN COURT (CASE #15M1400649) TO EITHER SUBMIT AN ENGINEER'S REPORT THAT THE ROOF TRUSS WORK REPAIRS ARE ADEQUATE OR WILL REPAIR ANY INSUFFICIENT WORK BY THE NEXT COURT DATE OF 9/24/15.. INSPECTOR TREJO #BL01001 | 6817 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANES BROKEN. | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | FRONT MISSING ADDRESS DISPLAY | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO VERIFY COMPLAINT #B100128744 | 6817 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
INSTALL GFCIS THROUGHOUT FIRST FLOOR. 18-27-210.8. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View | |
PROVIDE | 6821 - STORED VEHICLES IN BUILDING. 3(13-56-200). | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 6821 - NO HEAT. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | NO GREASE TRAP AT KITCHEN SINK - 6817 SECOND FLOOR. 18-29-1003.3.2. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | PVC WASTE AND VENT PIPING - 6821 SOUTHWEST ELEVATION. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | REMOVE EXTENSION CORDS THROUGHOUT BUILDING FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION THROUGHOUT BUILDING, FIRST FLOOR. | 6817 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |