Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 3:32 AM
PIN: 20224090140000
Property Address: 6817 S SOUTH CHICAGO AVE
City - Zip: CHICAGO - 60637
2023 Property Class: 593
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70030
2023 Tax District: 70147
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 71 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL EXTERIOR WALL MORTAR MISSING. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
PARAPET NORTH PARAPET WALL BUCKLING AND MORTAR MISSING. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
REPAIR COPING NORTH COPING TILES MISSING. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR EXTERIOR WOOD DOORS ROTTED, WOOD SPLIT, METAL DOORS RUSTED OUT. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME EXTERIOR WOOD DOOR FRAMES ROTTED, WOOD SPLIT, METAL DOOR FRAMES RUSTED. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
REPAIR EAVES SOUTH ELEVATION FASCIA BOARD ROTTED, METAL SIDING MISSING AND LOOSE. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR SR#801997687 NO PERMIT POSTED FOR ROOF REPAIRS EAST ELEVATION TORN AND MISSING ROOFING MATERIAL. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR SR#801997687 NO PERMIT POSTED FOR ROOF REPAIRS EAST ELEVATION TORN AND MISSING ROOFING MATERIAL. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
NO POSTED ADDRESS FRONT MISSING ADDRESS DISPLAY 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
PARAPET PARAPET WALL ON THE NORTH EAST ELEVATION ERODED MORTAR JOINTS AND SPRAWLING AND MISSING BRICK. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
REPAIR LINTELS LINTELS ON THE NORTH ELEVATION OVER DOOR WAY, NORTHEAST ELEVATION OVER WINDOWS AND DOOR OPENINGS. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE GARDEN HOSE FOR GRANITE CUTTING SAW THAT RUNS FROM SOUTH ELEVATION OF 6823 TO NORTH ELEVATION 6833. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE RPZ FOR GRANITE WATER CUTTING SAY NORTH ELEVATION OF 6833. 18-29-608.13.2. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE SERVICE SINK AND DRINKING FOUNTAIN FOR WAREHOUSE 6821 - 6851. 18-29-403.2 AND 403.4. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE TEMPERING VALVES AT MENS AND WOMENS LAVATORIES - 6819 FIRST FLOOR. 18-607.1. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT NO PERMITS FOR SECOND FLOOR LARGE ASSEMBLY - 6817. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE TEMPERING VALVE AT LAVATORIES - 6817 SECOND FLOOR RESTROOMS. 18-29-607.1. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE FLOOR DRAIN FOR WATER HEATER - NORTHEAST ELEVATION OF 6817 SECOND FLOOR. 18-29-412.4. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT PROVIDE OPEN FRONT TOILET SEATS ON ALL TOILETS AT 6817 SECOND FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PERMITS FOR VIOLATIONS AT 6817-51. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK AT 6817-51. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SEAL DRAIN OPENING UNUSD FIXTR OPEN TWO INCH BENT PIPES SOUTHEAST ELEVATION - 6823 FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE FIRST AND SECOND FLOOR AT 6817 SOUTH CHICAGO AND FIRST FLOOR OF 6819, 6821, AND 6823 S SOUTH CHICAGO 13-12-380 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PRV DISCHARGE PIPE FROM PRV DISCHARGE PIPE MISSING FOR RELIEF VALVE, 6819 FIRST FLOOR NORTH ELEVATION. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE FLEXIBLE SUPPLIES ON LAVATORY IN WOMENS RESTROOM AND KITCHEN FAUCET IN 6817 SECOND FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SYSTEM III INSTALL EMERGENCY LIGHTING SYSTEM III THROUGHOUT BUILDING, FIRST AND SECOND FLOORS. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURES THROUGHOUT FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# 6817 - NO OWNER POSTING. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL 6817 - WEST WALL HAS STRESS CRACK. NORTH WALL DEFLECTS OUT AND MISSING MORTAR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
POST APPROVED OCCUPANCY CARD 6817 - MISSING OCCUPANCY CARD. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE 6817 - SHOW PROOF OF 4 HOUR FIRE SEPARATION FROM LARGE ASSEMBLY TO MERCANTILE BELOW. 13-56-280. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE SECOND FLOOR SOCIAL CLUB/LARGE ASSEMBLY 2139 SQ FT WITH AN EXIT CAPACITY OF 356 PEOPLE. THE FRONT AND REAR EXITS HAVE A COMBINED CAPACITY FOR 180 PEOPLE. THERE IS AN INSUFFICIENT AMOUNT OF EXITS FOR THIS 6817 - TYPE OF OCCUPANCY. PROVIDE ADDITIONAL EXITS TO HANDLE THE 356 CAPACITY. 13-84-180B.6817 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE 6817 - FRONT AND REAR EXIT STAIRWELLS REQUIRE ONE HOUR FIRE RATED DOOR ASSEMBLY AND HARDWARE. 13-160-500A. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE 6817 - FRONT AND REAR EXIT DOORS REQUIRE PANIC HARDWARE. 13-160-260B. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE 6817 - REAR EGRESS EXIT DOOR ONLY 32 INCHES WIDE, ALL EXIT DOORS REQUIRE 36 INCHES FROM SECOND TO FIRST. 10(13-160-220A). 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL 6817 - MISSING FIRE EXTINGUISHERS. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR 6817 - SECOND FLOOR SOCIAL CLUB HAS WOOD FRAMED NON-LOAD BEARING WALLS FORMING A STORAGE ROOM AND ONE MENS RESTROOM AND ONE WOMENS RESTROOM. REQUIRES PLANS AND PERMITS. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR 6819 - INTERIOR BUILD OUT WITH WOOD PARTITION WALLS CONTAINING THREE LARGE ROOMS WITH TWO RESTROOMS AND ONE SMALLER ROOM HAS A WOOD FRAMED BAR. ALL WORK WAS COMPLETED WITHOUT THE REQUIRED PLANS AND PERMITS. REPAIRS TO BOW TRUSS ROOF REQUIRES PERMIT. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL 6819 - MISSING FIRE EXTINGUISHER. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
RATS-ELEVATE MATERIAL 18" 6821 - WOOD PALLETS, MISC. WOOD STORED AND SITTING ON GROUND. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
REMOVE 6821 - USING A PROPANE HEATER FOR HEAT. IMPROPER APPLICATION OF PROPANE HEATER IS DANGEROUS IN THIS SITUATION. 13-196-440. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 6821 - MISSING CARBON MONOXIDE DETECTOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE 6821 - DISCONTINUE USING AS AN AUTO REPAIR SHOP. NOT SET UP FOR A REPAIR SHOP. NUMEROUS CAR ENGINES THROUGHOUT REAR OF BUILDING. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG 6823 - EXPIRED FIRE EXTINGUISHER TAG. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) 6823 - BOW STRING TRUST HAS HOLLOW METAL TUB SHORING SITTING ON UNKNOWN AND BLOCKS OF WOOD FOOTINGS. WILL REQUIRE A STRUCTURAL ENGINEERS REPORT. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE 6833 - STORED RIDING LAWN MOWERS, BACKHOES, CRANE, AUTOMOBILES, CONSTRUCTION MATERIALS. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT NO PERMITS FOR RESTROOM - 6821 SOUTHWEST ELEVATION. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER - 6821 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE PROPER GREASE INTERCEPTOR FOR AUTOMOBILE REPAIR SHOP - 6821 FIRST FLOOR NORTH ELEVATION, 18-29-1003.7.2. AND 6833 WHERE MACHINES ARE STORED (BACKHOE, DUMP TRUCK, BOB CATS, CARS). 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE FLEXIBLE SUPPLIES ON LAVATORY AND TOILET - WEST ELEVATION AT 6819 FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT PROVIDE OPEN FRONT TOILET SEAT - WEST ELEVATION RESTROOM AT 6819 FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT NO PERMITS FOR RESTROOMS AND KITCHEN - 6819 FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REMOVE ALL PVC WASTE PIPE FOR RESTROOMS SOUTH ELEVATION AND KITCHEN AREA NORTH ELEVATION - 6819 FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE MINIMUM NUMBER OF PLUMBING FIXTURES FOR A LARGE ASSEMBLY. TOTAL AT TIME OF INSPECTION WAS TWO RESTROOMS TOTAL WITH ONE LAVATORY AND TOILET IN EACH RESTROOM. NO SERVICE SINK OR DRINKING FOUNTAIN AT 6819 FIRST FLOOR. 18-29-403.1. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE THE REQUIRED DIAGRAM AND LOAD CALCULATIONS FOR FEEDERS, SERVICES, AND REQUIRED EQUIPMENT 18-27-215.5 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER THROUGHOUT 6817 S SOUTH CHICAGO ON THE FIRST AND SECOND FLOOR AREAS AND 6819, 6821, 6823 S SOUTH CHICAGO ON THE FIRST FLOOR AREAS 18-27-110.12 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
NO PERMIT WIRING OBTAIN ELECTRICAL PERMIT AND AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS AND PERMITS THROUGHOUT 6817 S SOUTH CHICAGO FIRST AND SECOND FLOOR AREAS AND 6819, 6821, 6823 FIRST FLOOR AREAS, INCLUDING THE NEW 800 AMP SERVICE 13-12-360 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE PROVIDE MINIMUM NUMBER OF PLUMBING FIXTURES FOR A LARGE ASSEMBLY OF 356 PEOPLE. TOTAL AT TIME OF INSPECTION: MENS ROOM WITH ONE LAVATORY, ONE TOILET, AND ONE URINAL; WOMENS RESTROOM WITH ONE LAVATORY AND TWO TOILETS. NO SERVICE SINK OR DRINKING FOUNTAIN FOR 6817 SECOND FLOOR. 18-29-403.1. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE 6817 - FRONT AND REAR EXIT STAIRWELLS REQUIRE A ONE HOUR FIRE RATED WALL. 15-8-140. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE NO FLOOR DRAIN AT WATER HEATER NORTH ELEVATION OF 6819 AT FIRST FLOOR. 18-29-412.4. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
WORK CONTRARY TO PERMIT FOLLOW UP INSPECTION REVEALS THAT TRUSS REPAIR DEVIATES FROM APPROVED PLAN. BUILDING OWNER IS ORDERED IN COURT (CASE #15M1400649) TO EITHER SUBMIT AN ENGINEER'S REPORT THAT THE ROOF TRUSS WORK REPAIRS ARE ADEQUATE OR WILL REPAIR ANY INSUFFICIENT WORK BY THE NEXT COURT DATE OF 9/24/15.. INSPECTOR TREJO #BL01001 6817 S SOUTH CHICAGO AVE PERMIT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WINDOW PANES BROKEN. 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
NO POSTED ADDRESS FRONT MISSING ADDRESS DISPLAY 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO VERIFY COMPLAINT #B100128744 6817 S SOUTH CHICAGO AVE PERIODIC FAILED View
INSTALL GFCIS THROUGHOUT FIRST FLOOR. 18-27-210.8. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE 6821 - STORED VEHICLES IN BUILDING. 3(13-56-200). 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 6821 - NO HEAT. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
PROVIDE NO GREASE TRAP AT KITCHEN SINK - 6817 SECOND FLOOR. 18-29-1003.3.2. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL PVC WASTE AND VENT PIPING - 6821 SOUTHWEST ELEVATION. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE EXTENSION CORDS THROUGHOUT BUILDING FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL ILLUMINATION THROUGHOUT BUILDING, FIRST FLOOR. 6817 S SOUTH CHICAGO AVE COMPLAINT FAILED View