The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBSTRUCTIONS IN EXIT WAY | 1ST FLOOR UNIT,FRONT AND REAR ENTRY DOORS WITH BURGLAR GATES. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH, GRADE TO 1ST FLOOR, LEDGER BOARD MISSING BOLTS,2 BY 8 JOISTS SPAN 10 FEET,STRINGER ARE DRY WALL SCREWED AT TOP CONNECTION,STAIR RAILS ARE LADDER TYPE.REAR ENCLOSED PORCH GRADE TO ATTIC,FOUNDATION STATUS UNKNOWN,LEDGER BOARD UNKNOWN COVERED WITH DRY WALL,JOISTS UNKNOWN COVERED WITH DRY WALL,BEAMS ARE 4 BY 6 TOE NAILED AT FIRE CUT ONLY,COLUMNS ARE 4 BY 6 COVERED WITH DRY WALL,RAILINGS ARE LADDER TYPE,LOOSE AND PULLING,STAIR STRINGERS ARE FACE NAILED AT TOP CONNECTION WITH SCABB BLOCKING,STAIRS FROM 2ND FLOOR TO ATTIC MISSING HAND RAIL,AND GUARD RAIL AT ATTIC ELEVATION,PLANS AND PERMIT FOR REPAIRS. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION,1ST FLOOR.EAST ELEVATION,2ND FLOOR,BROKEN PANES. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 1ST FLOOR UNIT,MISSING BED ROOM DOORS. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | REAR ENTRY DOOR AT GRADE,MISSING DEADBOLT LOCK. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST AND 2ND FLOOR ENTRY DOORS MISSING PEEPHOLES. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING NO OWNERS I D SIGN POSTED. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT FURNACE AREA,1ST FLOOR UNIT,FRONT AND REAR STAIRWAYS,ATTIC FURNACE AREA,MISSING SMOKE DETECTORS. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT FURNACE AREA,1ST FLOOR UNIT,ATTIC FURNACE AREA,MISSING CARBON MONOXIDE DETECTORS. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1ST FLOOR UNIT,UNDER KITCHEN SINK,EXPOSED WIRING. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 2ND FLOOR REAR ENCLOSED PORCH,ADDITIONAL ROOM BUILT WITH DOORWAY ACCESS FROM 2ND FLOOR UNIT KITCHEN AREA,NO PERMIT ON FILE. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | WEST AND EAST ELEVATION,6 FOOT IRON FENCE BUILT,SOUTH AND NORTH ELEVATION,6 FOOT WOODEN FENCE BUILT,NO PERMIT ON FILE. | 8515 S BRANDON AVE | COMPLAINT | FAILED | View |