Chicago Building Violations Data: 34 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM REAR PORCH WITH CENTER DECK COLUMN WITHOUT A FOUNDATION FOOTING UNDER IT. 2) INSIDE H.R NOT AT 34" IN HEIGHT. 3) NORTH EAST COLUMNS ARE 4X6 NOT 6X6. 4) REPLACE JOISTS AND ANGLE BRACKET SCREWS WITH NON CORROSIVE NAILS. 4908 W BYRON ST PERMIT FAILED View
DEFECTIVE OUTLETS THROUGHOUT (BASEMENT APARTMENT) 4908 W BYRON ST COMPLAINT PASSED View
EXPOSED WIRING FIXTURES KITCHEN FRONT ROOM (BASEMENT APARTMENT) 4908 W BYRON ST COMPLAINT PASSED View
DEFECTIVE FIXTURES BACK PORCH 4908 W BYRON ST COMPLAINT PASSED View
NO PERMIT WIRING PERMIT REQUIRED 4908 W BYRON ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 3 STORY PORCH**STAIR SYSTEM IS LATERALLY UNSTABLE-ADD CROSS BRACING**MULTIPLE MISSING BANISTER PICKETS**CRACKED/SPLINTERED STAIR TREADS 1ST TO 2CD**MULTIPLE FAILED BANISTER CONECTIONS W/ NAILED JOINTS PULLING APART**NO BOLTS AT STAIR STRINGERS**ALL BANISTERS ARE TOOO LOW()36")REQUIRED HEIGHT IS (42")**1ST LEVEL PORCH DECK-NO LEDGER BOLTS**FRONT PORCH-LOOSE STAIR BANISTER. 4908 W BYRON ST COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR FOR ALL PORCH REPAIRS-PLANS ARE REQUIRED.NO PERMIT OBTAINED FOR PREVIOUS SUBSTANDARD PORCH REPAIRS. 4908 W BYRON ST COMPLAINT PASSED View
PIPE OPENING W/NONCOMBUST MATL 2 FLUE PIPES AT EXTERIOR(BSMNT-WEST_AND(2SD-NORTH)**THESE FLUE PIPES ARE CONTACTING THE BUILDINGS VINYL SIDING-FIRE HAZARD. 4908 W BYRON ST COMPLAINT PASSED View
ARRANGE FOR REINSPECTION REGAR PREVIOUS STOP WORK ORDER ISSUED (#9930)**FOR WORK PERFORMED IN ATTIC-PROBABLE ATTIC AND BASEMENT APARTMENTS(1 EXIT)**NEED ACCESS TO VERIFY OCCUPANCY. 4908 W BYRON ST COMPLAINT PASSED View
PROVIDE GUTTER & DOWNSPOUT EAST AND WEST ELEVATIONS NO GUTTERS AND DOWNSPOUTS 4908 W BYRON ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SIDE BASEMENT WINDOW BROKEN 4908 W BYRON ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# OWNER MANEGMENT SIGN NOT VISEBLE FROM PUBLIC WAY. 4908 W BYRON ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT PORCH STRUCTURE WITH THE FOLLOWING DEFECT,1) STRINGERS CONNECTIONS NAILED.2) 2X6 JOIST CONNECTIONS NAILED.3) SINGLE 2X6 JOIST CONNECTIONS NAILED.4) LEDGER CONNECTIONS NAILED.5) GUARD RAILS MISSING BOTTOM RAIL.6) PLANS AND PERMITS REQUIRED FOR REPAIRS AND REPLACMENT. 4908 W BYRON ST COMPLAINT FAILED View
PLANS & PERMITS REQUIRED PROVIDE APPROVED PLANS AND PERMITS FOR DORMER WEST AND EAST ELEVATION. 4908 W BYRON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH SYSTEM WITH THE FOLLOWING DEFECTS,1) BEAM TO COLUNM CONNECTIONS INSUFFICIENT AMOUNT OF ANCHORS.2) 6X6 COLUNMS LAP JOINTS UNDER SIZED 12 INCH.3) GUARD RAILS ALL MISSING CENTER NEWEL POSTS.4) 4X4 CROSS BRASING THRU-OUT STRUCTURE.5) NO VERIFIABLE FOOTINGS FOR 6X6 COLUNMS AND 4X4 COLUNMS.6) STRINGER REINFORCEMENT NAILED.7) STRINGER CONNECTIONSNAILED.8) PLANS AND PERMITS REQUIRED. 4908 W BYRON ST COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT DOWN SPOUT AND GUTTERS MISSING ON WEST AND EAST ELEVATION. 4908 W BYRON ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO WOOD ONE STORY FRONT PORCH AND REAR THREE STORY WOOD PORCH OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 4908 W BYRON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL LOWER BRICKS WALLS LOOSE AND OPEN MORTAR JOINTS , SPALLED BRICKS WITH FLAKING MASONRY COATING 4908 W BYRON ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR YARD ABANDON MOTORCYCLE STORED UNDER WOOD PORCH . 4908 W BYRON ST COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT AND REAR EXTERIOR BASEMENT AREAWAYS , MISSING GUARDRAILS AND HANDRAILS. 4908 W BYRON ST COMPLAINT FAILED View
REPAIR FENCE REAR SIX FOOT HIGH WOOD YARD FENCE , ROTTED , LEANING AND LOOSE WITH GATE BROKEN OFF. FENCE OVER FIVE FOOT HIGH REQUIRES PERMIT. 4908 W BYRON ST COMPLAINT FAILED View
GRADE AND DRAIN LOT REAR GRAVEL PARKING AREA - RUTS , HOLES AND STANDING WATER . NO HARD PAVEMENT. 4908 W BYRON ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT FIRST FLOOR ENTRY DOOR FLAKING PAINT , DENTED METAL. 4908 W BYRON ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED DETECTORS , CONDITIONS AND OCCUPANCY. 4908 W BYRON ST COMPLAINT FAILED View
SERVICE DROP OUT OF REACH REAR PORCH OFF SECOND FLOOR DECK -POWER SERVICE CABLE WITHIN REACH OF OCCUPANTS . 4908 W BYRON ST COMPLAINT FAILED View
SCAVENGER SERVICE TWO CITY TRASH CARTS FULL OF PORCH CONSTRUCTION DEBRIS . PROVIDE FOR PRIVATE TRASH CART . 4908 W BYRON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 3-STORY WOOD PORCH/ ALL RAILINGS - ONLY NAILED TO COLUMNS AND POSTS. STAIR TREADS - LOOSE.2ND TO 3RD FLOOR / ELECTRICAL WIRES - WITHIN REACH. 4908 W BYRON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION/ EXTERIOR WALL - WASHED OUT MORTAR. 4908 W BYRON ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT ELEVATION/ BASEMENT WINDOW - BROKEN PANE. 4908 W BYRON ST COMPLAINT FAILED View
INSPECT CONSTRUCTION WORK PERMIT # 100667748 ISSUED 10/17/16 FOR NEW DORMER AT EAST AND WEST, INTERIOR REMODELING AND REPAIR WOOD PORCHES AT FRONT AND REAR.PERMIT # 100712129 ISSUED 6/23/17 AS REVISION TO PERMIT #1006677748 TO CHANGE GC TO VIO DEVELOPERS LLC. PERMIT # 100723567 ISSUED 8/30/17 TO CHANGE GENERAL CONTRACTOR.THESE PLANS AND PERMITS NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 4908 W BYRON ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR AND REAR PORCH NEED OWNER AT SITE FOR INSPECTION PER TENANT 4908 W BYRON ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE REARBJUNK AND DEBRIS 4908 W BYRON ST COMPLAINT FAILED View
MAINTAIN WINDOW SASH EAST BASEMENT BLOCK WINDOWS MISSING LOUVER GLASS PANES. 4908 W BYRON ST COMPLAINT FAILED View
DEMO DEBRIS REAR AND FRONT YARDS - WOOD PILED 4908 W BYRON ST COMPLAINT FAILED View