Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH WITH CENTER DECK COLUMN WITHOUT A FOUNDATION FOOTING UNDER IT. 2) INSIDE H.R NOT AT 34" IN HEIGHT. 3) NORTH EAST COLUMNS ARE 4X6 NOT 6X6. 4) REPLACE JOISTS AND ANGLE BRACKET SCREWS WITH NON CORROSIVE NAILS. | 4908 W BYRON ST | PERMIT | FAILED | View |
DEFECTIVE OUTLETS | THROUGHOUT (BASEMENT APARTMENT) | 4908 W BYRON ST | COMPLAINT | PASSED | View |
EXPOSED WIRING FIXTURES | KITCHEN FRONT ROOM (BASEMENT APARTMENT) | 4908 W BYRON ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | BACK PORCH | 4908 W BYRON ST | COMPLAINT | PASSED | View |
NO PERMIT WIRING | PERMIT REQUIRED | 4908 W BYRON ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY PORCH**STAIR SYSTEM IS LATERALLY UNSTABLE-ADD CROSS BRACING**MULTIPLE MISSING BANISTER PICKETS**CRACKED/SPLINTERED STAIR TREADS 1ST TO 2CD**MULTIPLE FAILED BANISTER CONECTIONS W/ NAILED JOINTS PULLING APART**NO BOLTS AT STAIR STRINGERS**ALL BANISTERS ARE TOOO LOW()36")REQUIRED HEIGHT IS (42")**1ST LEVEL PORCH DECK-NO LEDGER BOLTS**FRONT PORCH-LOOSE STAIR BANISTER. | 4908 W BYRON ST | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | FOR ALL PORCH REPAIRS-PLANS ARE REQUIRED.NO PERMIT OBTAINED FOR PREVIOUS SUBSTANDARD PORCH REPAIRS. | 4908 W BYRON ST | COMPLAINT | PASSED | View |
PIPE OPENING W/NONCOMBUST MATL | 2 FLUE PIPES AT EXTERIOR(BSMNT-WEST_AND(2SD-NORTH)**THESE FLUE PIPES ARE CONTACTING THE BUILDINGS VINYL SIDING-FIRE HAZARD. | 4908 W BYRON ST | COMPLAINT | PASSED | View |
ARRANGE FOR REINSPECTION REGAR | PREVIOUS STOP WORK ORDER ISSUED (#9930)**FOR WORK PERFORMED IN ATTIC-PROBABLE ATTIC AND BASEMENT APARTMENTS(1 EXIT)**NEED ACCESS TO VERIFY OCCUPANCY. | 4908 W BYRON ST | COMPLAINT | PASSED | View |
PROVIDE GUTTER & DOWNSPOUT | EAST AND WEST ELEVATIONS NO GUTTERS AND DOWNSPOUTS | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SIDE BASEMENT WINDOW BROKEN | 4908 W BYRON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER MANEGMENT SIGN NOT VISEBLE FROM PUBLIC WAY. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT PORCH STRUCTURE WITH THE FOLLOWING DEFECT,1) STRINGERS CONNECTIONS NAILED.2) 2X6 JOIST CONNECTIONS NAILED.3) SINGLE 2X6 JOIST CONNECTIONS NAILED.4) LEDGER CONNECTIONS NAILED.5) GUARD RAILS MISSING BOTTOM RAIL.6) PLANS AND PERMITS REQUIRED FOR REPAIRS AND REPLACMENT. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | PROVIDE APPROVED PLANS AND PERMITS FOR DORMER WEST AND EAST ELEVATION. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM WITH THE FOLLOWING DEFECTS,1) BEAM TO COLUNM CONNECTIONS INSUFFICIENT AMOUNT OF ANCHORS.2) 6X6 COLUNMS LAP JOINTS UNDER SIZED 12 INCH.3) GUARD RAILS ALL MISSING CENTER NEWEL POSTS.4) 4X4 CROSS BRASING THRU-OUT STRUCTURE.5) NO VERIFIABLE FOOTINGS FOR 6X6 COLUNMS AND 4X4 COLUNMS.6) STRINGER REINFORCEMENT NAILED.7) STRINGER CONNECTIONSNAILED.8) PLANS AND PERMITS REQUIRED. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | DOWN SPOUT AND GUTTERS MISSING ON WEST AND EAST ELEVATION. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO WOOD ONE STORY FRONT PORCH AND REAR THREE STORY WOOD PORCH OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | LOWER BRICKS WALLS LOOSE AND OPEN MORTAR JOINTS , SPALLED BRICKS WITH FLAKING MASONRY COATING | 4908 W BYRON ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD ABANDON MOTORCYCLE STORED UNDER WOOD PORCH . | 4908 W BYRON ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT AND REAR EXTERIOR BASEMENT AREAWAYS , MISSING GUARDRAILS AND HANDRAILS. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR SIX FOOT HIGH WOOD YARD FENCE , ROTTED , LEANING AND LOOSE WITH GATE BROKEN OFF. FENCE OVER FIVE FOOT HIGH REQUIRES PERMIT. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | REAR GRAVEL PARKING AREA - RUTS , HOLES AND STANDING WATER . NO HARD PAVEMENT. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT FIRST FLOOR ENTRY DOOR FLAKING PAINT , DENTED METAL. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED DETECTORS , CONDITIONS AND OCCUPANCY. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | REAR PORCH OFF SECOND FLOOR DECK -POWER SERVICE CABLE WITHIN REACH OF OCCUPANTS . | 4908 W BYRON ST | COMPLAINT | FAILED | View |
SCAVENGER SERVICE | TWO CITY TRASH CARTS FULL OF PORCH CONSTRUCTION DEBRIS . PROVIDE FOR PRIVATE TRASH CART . | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3-STORY WOOD PORCH/ ALL RAILINGS - ONLY NAILED TO COLUMNS AND POSTS. STAIR TREADS - LOOSE.2ND TO 3RD FLOOR / ELECTRICAL WIRES - WITHIN REACH. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION/ EXTERIOR WALL - WASHED OUT MORTAR. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT ELEVATION/ BASEMENT WINDOW - BROKEN PANE. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | PERMIT # 100667748 ISSUED 10/17/16 FOR NEW DORMER AT EAST AND WEST, INTERIOR REMODELING AND REPAIR WOOD PORCHES AT FRONT AND REAR.PERMIT # 100712129 ISSUED 6/23/17 AS REVISION TO PERMIT #1006677748 TO CHANGE GC TO VIO DEVELOPERS LLC. PERMIT # 100723567 ISSUED 8/30/17 TO CHANGE GENERAL CONTRACTOR.THESE PLANS AND PERMITS NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AND REAR PORCH NEED OWNER AT SITE FOR INSPECTION PER TENANT | 4908 W BYRON ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REARBJUNK AND DEBRIS | 4908 W BYRON ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | EAST BASEMENT BLOCK WINDOWS MISSING LOUVER GLASS PANES. | 4908 W BYRON ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | REAR AND FRONT YARDS - WOOD PILED | 4908 W BYRON ST | COMPLAINT | FAILED | View |